§ 172-5.1 — General standards. [Amended 7-19-06 by Ord. No. 06-083]
Code of the City of Jersey City, New Jersey (Supp. No. 53: covering ordinances through 26-016, passed February 11, 2026) · Jersey City Code § 172-5.1
Corpus is an independent public-information project, not the official City of Jersey City website. Stable reference: corpuslaw.us/code/efeff67f-71d0-4e2e-af62-a91c5583c96c
§ 172-5.1. - General standards. [Amended 7-19-06 by Ord. No. 06-083]
In all areas of special flood hazards the following standards are required: A. Anchoring. (1) All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure. (2) All manufactured homes shall be anchored to resist flotation, collapse or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. B. Construction materials and methods. (1) All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (2) All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. C. Utilities. (1) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system (2) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharge from the systems into floodwater. (3) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. (4) Electrical, heating, ventilation, plumbing and air-conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. D. Subdivision proposal. (1) All subdivision proposals shall be consistent with the need to minimize flood damage. (2) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. (3) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood damage. (4) Base flood elevation data shall be provided for subdivision proposals and other proposed development which contain at least fifty (50) lots or five acres (whichever is less) which is to be developed at one time or over a period of time as part of an overall project. E Enclosure openings. All new construction and substantial improvements having fully enclosed areas below the lowest floor that are usable solely for the parking of vehicles, building access, or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: (1) A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. (2) The bottom of all openings shall be no higher than one foot above grade. (3) Openings may be equipped with screens, louvers or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters.
Ask a question about Jersey City law
Corpus searches the Jersey City sections it holds and shows the ones that match, with their citations. Free, no sign-in.