Effluent limitations attainable by the application of the best available technology economically achievable (BAT).
40 C.F.R. § 432.93
in effectExcept as provided by 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BAT:
(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:
Effluent Limitations
[BAT]
Regulated
parameter
Maximum daily
1
Maximum monthly avg.
1
Ammonia (as N)8.04.0
1 mg/L (ppm).
(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the following effluent limitations:
Effluent Limitations
[BAT]
Regulated
parameter
Maximum daily
1
Maximum monthly avg.
1
Ammonia (as N)8.04.0
Total Nitrogen194134
1 mg/L (ppm).