For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 40-62 — Minimum requirements for rat stoppage; approval of alternate rat-stoppage construction

Code of Ordinances, City of Corpus Christi, Texas (Supp. No. 44: codified through Ordinance No. 033940, enacted June 2, 2026) · Corpus Christi Code of Ordinances § 40-62

Corpus is an independent public-information project, not the official City of Corpus Christi website. Stable reference: corpuslaw.us/code/f0119ac1-1636-45e8-bf7f-1a10ef1809f6

Sec. 40-62. - Minimum requirements for rat stoppage; approval of alternate rat-stoppage construction.

For the purpose of obtaining rat stoppage of business buildings, the regulations set forth in the following subsections shall be the minimum requirements for applying rat stoppage to business buildings: (1) Protective coating of metal. Solid sheet metal, expanded metal and wire cloth specified in these regulations shall have a rust-resisting, protective coating. (2) Covering of foundation wall ventilator openings. All foundation wall ventilator openings shall be covered for their entire height and width with perforated sheet metal plates of a thickness not less than fourteen (14) gauge, or with expanded sheet metal of a thickness not less than eighteen (18) gauge, or with cast-iron grills or grates, or with any material of sufficient strength and equal rat-resisting properties. The openings therein shall be small enough to prevent the ingress of rats, and in no instance shall be larger than one-half (½) inch mesh. (3) Closing of foundations and exterior wall openings. All foundations and exterior wall openings, excluding those used for the purpose of ventilation, light, doors and windows, such as those openings around pipes, electric cables, conduits, openings due to deteriorated wall, broken masonry or concrete, shall be protected against the ingress of rats by closing such openings with cement mortar, concrete or masonry, or close-fitting sheet metal or suitable size pipe flanges or other material with equal rat-resisting properties, which shall be securely fastened in place. (4) Doors. All exposed edges of the lower eight (8) inches of wooden doors and door jambs, serving as front, rear or side entrances into business buildings, from the ground, basement or cellar floors, and other doors accessible to rats, shall be protected against the gnawing of rats by covering such doors and jambs with solid sheet metal of not less than twenty-four (24) gauge thickness. The same material shall be used on door sills or thresholds, or such door sills or thresholds may be constructed of cement, stone, steel or cast iron. Doors, door jambs and sills of coal chutes and hatchways that are constructed of wood shall be covered with solid sheet metal of twenty-four (24) gauge or heavier, or they may be replaced with metal chutes of twenty-four (24) gauge or heavier installed in such manner as will prevent the ingress of rats. All buildings with side and rear door entrances shall be provided with fly screen and hardware cloth doors. Such doors shall be provided with suitable automatic self-closing devices. All doors on which metal channel flashing has been applied shall be properly hinged to provide for free swinging. When closed, doors shall fit snugly so that the maximum clearance between any door, door jamb and sill shall not be greater than three-eighths (⅜) of an inch. (5) Windows. All windows and other openings for the purpose of light or ventilation shall be covered for their entire height and width, including frame, with wire cloth of nineteen (19) gauge or heavier, in installed metal frames of twenty-four (24) gauge and anchored in place with rust-resisting screws, having a mesh of not larger than one-half (½) inch. All windows and other openings for the purpose of light or ventilation that may be accessible to rats by way of exposed pipes, wires, conduits and other appurtenances, shall be covered as specified above. In lieu of wire cloth covering, such pipes, wires, conduits and other appurtenances shall be blocked from rat usage by installing sheet metal guards of twenty-four (24) gauge or heavier. Such guards when used on vertical pipes, wires, conduits or other appurtenances shall be fitted snugly around the pipe, wire, conduit or other appurtenance. (6) Light wells. Light wells with windows in exterior walls that are located below the outside ground level shall be protected from the ingress of rats by one of the following methods: (a) Installing over light wells cast-iron or steel grills or steel gratings, or other material of equal strength and rat-resisting properties, with openings in grills or gratings not to exceed one-half (½) inch in largest dimension. (b) Installing securely to and completely covering existing metal grills that are broken or have openings larger than one-half (½) inch in largest dimension or are otherwise defective, with expanded metal of eighteen (18) gauge or heavier, having openings not greater than one-half (½) inch in largest dimension. At the option of the owner, the opening in the wall of the building below the grate may be entirely closed with brick or concrete or partially closed and the remaining open space covered with nineteen (19) gauge or heavier wire cloth with mesh not to exceed one-half (½) inch. (7) Wood frame exterior construction; curtain walls; replacing wood floors with concrete; openings in ground floors. Business buildings constructed on piers having wooden floor sills less than twelve (12) inches above the surface of the ground shall have the intervening space between the floor sill and the ground protected against the ingress of rats by installing a solid masonry or concrete curtain wall not less than four (4) inches thick around the entire perimeter of the business building and extending such curtain wall to a depth of not less than eighteen (18) inches deep with a twelve (12) inch shelf extending outward from the wall and fastening securely to the exterior wall of the business building, in such a manner as will prevent rats from entering the building. In the four (4) inch curtain wall a screened-in ventilator one hundred forty-four (144) square inches in size, in accordance with specifications set out in this article shall be placed every ten (10) lineal feet around the building. All water, gas, sewer or electrical conductors which pass through this wall shall be protected with sleeves of the proper size. If wood floor inside of building is replaced with a concrete slab, gas piping, if any, beneath the floor shall be rerun into the building above the new floor level. Business buildings constructed on piers having wooden floor sills greater than twelve (12) inches above the ground level shall have the intervening spaces between the floor sill and the ground protected against the ingress of rats by installing curtain walls in accordance with the preceding paragraph by protecting such business buildings against the ingress of rats by installing solid sheet metal coverage of twenty-four (24) gauge or heavier snugly around each pipe, cable, wire, conduit or other utility service passing through the wooden ground floor. Such metal coverage shall not be less than eight (8) inches in diameter larger than diameter of the pipe, cable, wire, conduit or other utility service, and shall be securely fastened to the wooden floor. All other openings in wooden ground floors through which rats may gain entrance into double walls or the interior of business buildings, such as openings that may exist in floors and double walls above the floor sills, shall be closed with twenty-four (24) gauge or heavier solid sheet metal or sixteen (16) gauge or heavier wire cloth of one-half (½) inch mesh or masonry or with concrete masonry. Wood frame constructed business buildings having concrete or masonry foundation walls shall have ventilators in foundation walls protected as provided in subsection (3) of this section. All miscellaneous wall openings, doors and windows shall be protected in accordance with this article. In lieu of the installation of curtain walls, all, ground floors of wood construction may be replaced with concrete of not less than three (3) inches in thickness. Exterior wall protection shall be securely tied in a ratproof manner into the concrete floor at all points. The public health officer, or his representative, shall approve the method of installations for any other rat-stop-page construction of a business building which are not specified in the foregoing subsections of this section.

(Code 1958, § 31-19)

Ask a question about Corpus Christi law

Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.