§ 21.205 — FLOODWAY DISTRICT
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 21.205
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/f18a3775-c1b1-4973-a7b2-6c3699c93097
21.205 - FLOODWAY DISTRICT.
(1) No modification or addition shall be allowed to any nonconforming structure or any structure with a nonconforming use in the Floodway District, unless such modification or addition: (a) Has been granted a zoning certificate or variance which meets all ordinance requirements; (b) Meets the requirements of subchapter 21F; (c) Shall not increase the obstruction to flood flows or regional flood height; (d) Any addition to the existing structure shall be floodproofed, pursuant to subsection 21.27, by means other than the use of fill, to the flood protection elevation; and, (e) If any part of the foundation below the flood protection elevation is enclosed, the following standards shall apply: 1. The enclosed area shall be designed by a registered architect or engineer to allow for the efficient entry and exit of flood waters without human intervention. A minimum of two (2) openings must be provided with a minimum net area of at least one (1) square inch for every one (1) square foot of the enclosed area. The lowest part of the opening can be no more than twelve (12) inches above the adjacent grade; 2. The parts of the foundation located below the flood protection elevation must be constructed of flood-resistant materials; 3. Mechanical and utility equipment must be elevated or floodproofed to or above the flood protection elevation; and 4. The use must be limited to parking, building access or limited storage. (2) No new onsite sewage disposal system, or addition to an existing onsite sewage disposal system, except where an addition has been ordered by a government agency to correct a hazard to public health, shall be allowed in the Floodway District. Any replacement, repair or maintenance of an existing onsite sewage disposal system in a floodway area shall meet the applicable requirements of all City ordinances, subsection 21.27(3) and Ch. SPS 383, Wis. Adm. Code. (3) No new well or modification to an existing well used to obtain potable water shall be allowed in the Floodway District. Any replacement, repair, or maintenance of an existing well in the Floodway District shall meet the applicable requirements of all City ordinances, subsection 21.27(3) and Chs. NR 811 and NR 812, Wis. Adm. Code.
(Cr. by ORD-25-00012, 3-20-25; Am. by ORD-25-00076, 11-6-25)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.
