§ 15.01.140 — Electrical permit exemptions
Henderson Municipal Code (Supp. No. 59: codified through Ordinance No. 4163, adopted June 16, 2026) · Henderson Municipal Code § 15.01.140
Corpus is an independent public-information project, not the official City of Henderson website. Stable reference: corpuslaw.us/code/f1e9fb32-cc67-45d6-825f-2af803022932
15.01.140 - Electrical permit exemptions.
An electrical permit shall not be required for the following: A. Installations under the exclusive control of electrical utilities governed by the State of Nevada Pubic Service Commission for the purpose of communication or metering or for the generation, control, transformation, transmission and distribution of electric energy located in buildings used exclusively by utilities for such purposes, or located outdoors on property owned or leased by the utility or on public highways, streets, roads, etc., or outdoors by established rights on private property; B. Portable motors or other portable appliances having an approved listing for use by means of a cord or cable having an attachment plug end to be connected to an approved receptacle as permitted by the electrical code; C. Repair or replacement of fixed motors, transformers or fixed approved appliances of the same type and rating in the same location; D. Temporary decorative lighting; E. Repair or replacement of electrical current-carrying parts of any switch, contactor or control device; F. Reinstallation of attachment plug receptacles, but not the outlets thereof; G. Repair or replacement of any over-current device of the required capacity in the same location; H. Repair or replacement of electrodes or transformers of the same size and capacity for signs or gas tube systems; I. Taping or wrapping of joints and splices; J. Removal of electrical wiring and outline lighting; K. Temporary wiring for experimental purposes in suitable experimental laboratories; L. The wiring for temporary theater, motion picture or television stage sets; M. Signal wiring outside of buildings installed by licensed and franchised cable television, telephone or buried cable installers; N. Power-limited wiring of 50 volts or less in or associated with single-family dwellings; O. Surface-mounted power-limited wiring; P. Power limited Class II and III wiring not part of a fire warning system, control wiring for emergency power systems, or smoke control systems; Q. Replacement of lighting fixtures in single family residences, dwelling units, guest rooms and guest suites as defined in the NEC. Exemption from the permit requirements of this chapter does not authorize any work to be done in violation of the provisions of this chapter, the technical codes, or any other pertinent ordinances, laws or regulations of the City of Henderson.
(Ord. No. 3141, § 1, 4-1-2014; Ord. 2736, § 1 (part), 2008)
Ask a question about Henderson law
Corpus searches the Henderson sections it holds and shows the ones that match, with their citations. Free, no sign-in.