§ 49-1303 — Dual vents
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-1303
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/f2671443-020c-4a2b-9d64-1646e399dddd
Sec. 49-1303. - Dual vents.
Two identical purpose fixtures adjacent or located on opposite sides of a wall (or partition) may be served with one soil, waste or vent pipe with the following restrictions: (a) Each fixture branch length shall be within the prescribed distance allowed in section 49-1403. (b) Soil, waste and vent pipes shall be sized equivalent to individual installation. Exception: Two water closets shall have at least a two-inch vent.
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.
