Sec. 49-1303. - Dual vents.

Two identical purpose fixtures adjacent or located on opposite sides of a wall (or partition) may be served with one soil, waste or vent pipe with the following restrictions: (a) Each fixture branch length shall be within the prescribed distance allowed in section 49-1403. (b) Soil, waste and vent pipes shall be sized equivalent to individual installation. Exception: Two water closets shall have at least a two-inch vent.

(Ord. No. 40524, § 1, 10-20-15)