§ 19-206 — Water and sanitation
Code of Ordinances of the City of Tyler, Texas (September 2026: including amendments through September 9, 2026) · Tyler City Code § 19-206
Corpus is an independent public-information project, not the official City of Tyler website. Stable reference: corpuslaw.us/code/f5b83843-7244-4340-9085-992864bdf822
Sec. 19-206. Water and sanitation.
a. Plans and specifications. All plans and specifications for all residences or other plumbed buildings must contain provisions for proper sanitation and are subject to the approval of the City and State. b. On-site sewage disposal system. It is unlawful to employ as the method of sewage disposal on the Lake, any method other than an approved and permitted on-site sewage disposal system. All grey water shall be discharged to the approved and permitted on-site sewage disposal system. No grey water discharges to the surface or to an independent subsurface system are allowed. Sewage disposal systems shall be designed and installed in accordance with state law governing private sewage systems. Prior to construction, detailed plans for each system shall be submitted to all applicable approving authorities, copies of which are to be attached to the Approval for Construction submitted to the Director of Utilities. Formal written approval from all applicable approval authorities is required prior to initiating any construction on the system, including that of Tyler Water Utilities. All sewage effluent from either aerobic or anaerobic systems shall be disposed of in an approved spray irrigation field, or an approved subsurface drain field, with no effluent discharged to the surface within the 100' setback from 378' msl elevation or into the waters of the Lake. No part of the disposal system, including plumbing fixtures, collection and transport components may be located within 100 feet from the 378' msl elevation. An inspection of the on-site sewage system must be conducted annually by a licensed inspector for each approved sewage disposal system on the Lake effective November 18, 2011. The inspection report shall be submitted to the City at the time the annual lease fee is due on Lake Tyler lots and the annual registration fee is due for lots on Lake Tyler East. Any system may be inspected in response to a complaint, but at a minimum, all systems will be inspected annually. All inspections are to be coordinated by the lessee and shall include all collection/pumping facilities whether over the water or not. 1. Failure to submit the annual septic inspection for properties on Lake Tyler will result in the City withholding renewal of the lease. The City will not process lease renewal payments without the annual inspection report. Lake Tyler lease holders will have sixty (60) days to remedy any issues identified in the report. Failure to remedy will result in the City withholding renewal of such lease and reserves the right to begin the process of lease termination. 2. Failure to submit the annual septic inspection and use fee for properties on Lake Tyler East may result in a $500 fine. The City reserves the right to file a lien(s) on any property of Lake Tyler East for non -payment. Lake Tyler East property owners will have sixty (60) days to remedy any issues identified in the report. Failure to remedy will result in additional fines/liens to the extent limited under State Law. c. Sanitary facilities located inside the 100' setback from 378' msl elevation. No new sanitary facilities will be permitted within the 100' setback from the 378' msl elevation after the effective date of this Ordinance, April 11, 2025. The continued use of plumbing fixtures and collection and transport components that were lawfully obtained via variance granted by the City prior to August 19, 2022, may continue as legal non-conforming uses to be located inside the 100' setback from 378' msl elevation, if such use continues to comply with the following conditions: 1. The system must be designed by a registered professional engineer with experience in design of such systems. 2. Only one commode, one bathroom lavatory, one shower and/or tub, one kitchen sink (double compartment), one water heater, and one ice-maker/ice dispensing unit is allowed per boathouse. 3. Only a single wastewater collection tank is allowed per boathouse, and only when pumping is required to reach the disposal system located outside the 100' setback from 378' msl elevation. 4. Where a wastewater collection tank is required, the same shall be equipped with a sewage pump capable of pumping the volume required to meet specified engineering criteria for the system activated by means of a float switch. 5. Where a wastewater collection tank is required, the same shall be constructed of a corrosion resistant, non-buoyant material, and shall be located within a containment structure capable of holding 1 ½ times the volume of the tank. 6. Where a wastewater collection tank is required, the same shall be equipped with an audible and visual alarm system indicating tank leaks or overflow. 7. All pipe and fittings used to convey wastewater from the boathouse to the on-site sewage facility (OSSF) shall have a minimum working pressure rating of 150 pounds per square inch. Final plans and specifications shall describe and require pressure testing for all lines installed with the minimum test pressure being 1.5 times the maximum design pressure. All pipe and fittings used to convey water to the boathouse and wastewater from the boathouse to the OSSF shall be located above the 376' elevation and must be capable of being visually inspected. 8. The system will be subject to periodic, routine inspections by City Staff. 9. The system will be subject to an annual inspection as described in this Article. d. Floating boathouses, piers or any other on-water facility which has sanitary facility connections shall be prohibited. e. Pit toilets. It is unlawful to employ as the means of waste disposal any pit-type toilet on a Lake lot or on City property at the Lake. f. Garbage. It is unlawful to maintain any dump ground or garbage incinerator in the Lake Tyler watershed. All garbage shall be collected and removed from the lake shore at least once weekly by lessee. The burning of household garbage is prohibited on the Lake. g. Non-potable untreated (raw) water may be obtained from the Lake by the following means: 1. by lease holders and lot owners for irrigation purposes only, with a maximum 5 hp pump and a 2" supply line; or 2. by contractors upon obtaining a temporary water diversion permit from the State of Texas. (Ord. 0-97-52, 10/22/97) (Ord. No. 0-99-80, 10/20/99) (Ord. No. O-2011-100, 11/16/11) h. Insecticide Misting Systems. Insecticide misting systems are permitted for the use of controlling insects in and around piers, docks and boathouses. Misting systems shall be designed in accordance with the City of Tyler Water Utilities Misting System Guidelines. All insecticides used are subject to approval for use over surface water supplies by the Texas Department of Agriculture, Texas Parks and Wildlife Department and meet the criteria for EPA FIFRA 25(b) exemption. (Ord. No. 0-2025-17; 4/9/2025)
Ask a question about Tyler law
Corpus searches the Tyler sections it holds and shows the ones that match, with their citations. Free, no sign-in.