§ 14-74 — Building sewers and connections
Code of Ordinances, City of Batesville, Mississippi (Supp. No. 54: codified through Ordinance No. 2023-08-914, adopted August 15, 2023) · Batesville Code of Ordinances § 14-74
Corpus is an independent public-information project, not the official City of Batesville website. Stable reference: corpuslaw.us/code/f6196236-ab23-4daf-abfb-e4d09dcb2a3b
Sec. 14-74. - Building sewers and connections.
(a) Permit—Required. No unauthorized person shall uncover, make any connections with or opening into, use, alter or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the superintendent. (b) Same—Classes; application; fee. (1) There shall be two (2) classes of building sewer permits: (i) for residential and commercial service; and (ii) for service to establishments producing industrial wastes. In any case, the owner or his agent shall make application on a special form furnished by the city. The permit application shall be supplemented by any plans, specifications or other information considered pertinent in the judgment of the superintendent. A permit and inspection fee of one hundred fifteen dollars ($115.00) for a residential or commercial building sewer permit and one hundred fifteen dollars ($115.00) for an industrial building sewer permit shall be paid to the city at the time the application is filed. (2) As a condition for authorization to dispose of industrial wastes through the municipal system, the industrial applicant for a sewer permit shall provide the city with information describing wastewater constituents and characteristics, and the type of activity and quantity of production. (c) Costs; loss or damage. All costs and expenses incident to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the city from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer. (d) Separate buildings. A separate and independent building sewer shall be provided for every building; except where one (1) building stands at the rear of another or an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one (1) building sewer. (e) Old building sewers. Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the superintendent, to meet all requirements of this division. (f) Specifications. The size, slope, alignment, materials of construction of a building sewer and the methods to be used in excavating, placing of the pipe, jointing, testing and backfilling the trench, shall conform to the requirements of the building and plumbing code or other applicable rules and regulations of the city. In the absence of the code provisions or in amplification thereof, the materials and procedures set forth in appropriate specifications of the American Society for Testing and Materials (ASTM) and the Water Pollution Control Federation (WPCF) Manual of Practice No. 9 shall apply. (g) Elevation. Whenever possible, the building sewer shall be brought to the building at an elevation below the basement floor. In all buildings in which any building drain is too low to permit gravity flow to the pubic sewer, sanitary sewage carried by such building drain shall be lifted by an approved means and discharged to the building sewer. (h) Unpolluted water. No person shall make connection of roof downspouts, exterior foundation drains, areaway drains or other sources of surface runoff or groundwater to a building sewer or building drain which in turn is connected directly or indirectly to a public sanitary sewer. (i) Tightness; codes. The connection of the building sewer into the public sewer shall conform to the requirements of the building and plumbing code or other applicable rules and regulations of the city, or the procedures set forth in appropriate specifications of the ASTM and the WPCF Manual of Practice No. 9. All such connections shall be made gastight and watertight. Any deviation from the prescribed procedures and materials must be approved by the superintendent before installation. (j) Inspection; supervision. The applicant for the building sewer permit shall notify the superintendent when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the superintendent or his representative. (k) Excavations. All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the city.
(Ord. No. 83-242, Art. IV, 3-2-82; Ord. No. 92-08-433, Art. IV, 8-18-92)
Ask a question about Batesville law
Corpus searches the Batesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.