22.206.040 - Light and ventilation

A. Every habitable room in a housing unit shall have a window or windows providing natural light with an area of not less than 8 percent of the floor area of the room, but in no event shall such area be less than 10 square feet; provided, that an approved system of artificial light compliant with current Seattle Building Code standards may be used in lieu of the window or windows required by this section. B. Every habitable room in a housing unit and every laundry room shall have natural ventilation from an exterior opening with an area measuring at least 4 percent of the floor area of the room. In lieu of required exterior openings for natural ventilation in all habitable rooms and in laundry rooms, a mechanical ventilating system may be provided. Such system shall comply with the requirements of the Seattle Energy Code in effect on the date of installation and applicable requirements of the Mechanical Code. C. Every bathroom and water closet compartment shall be provided with natural ventilation by means of exterior openings with an area not less than five percent of the floor area of the room, but in no event shall such area be less than 1.5 square feet; provided, that in lieu of required exterior openings for natural ventilation, a mechanical ventilating system or vent shafts may be provided. Such system shall comply with the requirements of the Seattle Energy Code in effect on the date of installation and applicable requirements of the Seattle Mechanical Code. If a mechanical ventilation system is provided in laundry rooms or similar rooms, it shall be connected to the outside. D. For the purpose of determining light and ventilation requirements, any room may be considered a portion of an adjoining room if 1/2 of the area of the common wall is open and unobstructed and provides an opening of not less than 1/10 of the floor area of the interior room or 25 square feet, whichever is greater. E. Required exterior openings for natural light or natural ventilation shall open directly onto a street or public alley, or a yard or court adjacent to the required exterior opening; provided, that required exterior openings may open onto a roofed porch where the porch: 1. Abuts a street, yard, or court; and 2. Has a ceiling height of not less than 6 feet, 8 inches; and 3. Is at least 65 percent open and unobstructed for its length, or is open at both ends. F. Every yard, court, street, or alley having required windows facing thereon shall be not less than 3 feet in width and unobstructed to the sky.

(Ord. 125343, § 3, 2017; Ord. 123546, § 1, 2011; Ord. 115671, § 10, 1991; Ord. 113545 § 5, 1987.)

Ask a question about Seattle law

Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.