§ 20-230 — Floodplain management; standards of construction
Peoria, Arizona, City Code (2026 S-10: Local legislation current through Ord. 2026-20, passed 10-6-26) · Peoria, Ariz., City Code § 20-230
Corpus is an independent public-information project, not the official City of Peoria website. Stable reference: corpuslaw.us/code/f85d6a41-79d7-4ff0-a416-316147492d7c
Sec. 20-230. Floodplain management; standards of construction.
In all areas of special flood hazards the following standards are required: A. Anchoring. 1. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; and 2. All manufactured homes shall meet the anchoring standards of section 20-234.B. B. Construction Materials and Methods. 1. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; 2. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage; 3. All new construction, substantial improvement and other proposed new development shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and 4. Within Zones AH or AO, adequate drainage paths shall be constructed around structures on slopes to guide floodwaters around and away from proposed structures. C. Elevation and Floodproofing. 1. Residential construction. Residential construction, new or substantial improvement, shall have the lowest floor, including basement, a. In an AO Zone, elevated to or above the regulatory flood elevation, or elevated at least two feet above the highest adjacent grade if no depth number is specified. b. In an A Zone where a BFE has not been determined, elevated to or above the regulatory flood elevation or be elevated in accordance with the criteria established in Section 20-221.C. c. In Zones AE, AH and A1-30, elevated to or above the regulatory flood elevation. Upon completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community's building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. 2. Nonresidential construction. Nonresidential construction, new or substantial improvement, shall either be elevated to conform with Section 20-230.C.1 or together with attendant utility and sanitary facilities: basement, a. Be floodproofed below the elevation recommended under Section 20-230.C.1 so that the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and c. Be certified by a registered professional engineer or architect that the standards of this section are satisfied. Such certification shall be provided to the Floodplain Administrator. 3. Flood Openings. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. Designs for meeting this requirement must meet or exceed the following criteria: a. For non-engineering openings: 1. Have a minimum of two openings, on different sides of each enclosed area, having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding. 2. The bottom of all openings shall be no higher than one foot above grade. 3. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwater; or b. Engineered openings (or covers and devices) that are specifically designed and certified by a registered engineer or architect as meeting the required performance and design requirements. c. Engineered openings (or covers and devices) for which an Evaluation Report has been issued by the International Code Council (ICC) Evaluation Service, Inc. (ICC-ES), a subsidiary of the International Code Council, Inc. 4. Manufactured homes. Manufactured homes shall also meet the standards in Section 20-234. 5. Garages and low cost accessory structures. a. Attached garages. 1. A garage attached to a residential structure, constructed with the garage floor slab below the regulatory flood elevation, must be designed to allow for the automatic entry of flood waters. See Section 20-230.C.3. Areas of the garage below the regulatory flood elevation must be constructed with flood resistant materials. See Section 20-230.B. 2. A garage attached to a nonresidential structure must meet the above requirements or be dry floodproofed. b. Detached garages and accessory structures. 1. "Accessory structure" used solely for parking (2 car detached garages or smaller) or limited storage (small, low-cost sheds), as defined in Section 20-205, may be constructed such that its floor is below the regulatory flood elevation, provided the structure is designed and constructed in accordance with the following requirements: a) Use of the accessory structure must be limited to parking or limited storage; b) The portions of the accessory structure located below the regulatory flood elevation must be built using flood-resistant materials; c) The accessory structure must be adequately anchored to prevent flotation, collapse and lateral movement; d) Any mechanical and utility equipment in the accessory structure must be elevated or floodproofed to or above the regulatory flood elevation; e) The accessory structure must comply with floodplain encroachment provisions in Section 20-236; and f) The accessory structure must be designed to allow for the automatic entry of flood waters in accordance with Section 20-230.C.3. 2. Detached garages, storage structures and other accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in Section 20-230.C.1. (Ord. No. 98-102, 9/22/98; Ord. 2014-40, 11/25/14, Repealed and Enacted (SUPP 2014-4); Ord. No. 2021-18, § 12, 6-15-21)
Ask a question about Peoria law
Corpus searches the Peoria sections it holds and shows the ones that match, with their citations. Free, no sign-in.