18.40.540 - Amend CBC Section 2306.3—Wood-frame shear walls.

Section 2306.3 of the California Building Code is amended to read as follows: 2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with ANSI/AWC SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Table 4.3A of ANSI/AWC SDPWS shall include the following: 1. Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick and studs shall not be spaced at more than 16 inches on center. 2. The maximum nominal unit shear capacities for ⅜ inch wood structural panels resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 400 pounds per linear foot (plf). Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the building official. 3. Nails shall be placed not less than ½-inch in from the panel edges and not less than ⅜-inch from the edge of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be placed not less than ⅜-inch from panel edges and not less than ¼-inch from the edge of the connecting members for shears of 350 plf or less using ASD or 500 plf or less using LRFD. For structures assigned to Seismic Design Category D, E, or F, application of Table 4.3B of ANSI/AWC SDPWS shall not be allowed. For structures assigned to Seismic Design Category D, E, or F, application of Table 4.3C of AWC SDPWS shall not be used below the top level in a multi-level building for structures. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Tables 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B, or C. Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official. The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the ANSI/AWC SDPWS.

(ORD-25-0019 § 1(Exh. A), 2025)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.