§ 31-23 — IBC CHAPTER 12 INTERIOR ENVIRONMENT - amendments
Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-23
Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/f8cd4b77-f5f0-47c5-8195-033928448a62
Sec. 31-23. - IBC CHAPTER 12 INTERIOR ENVIRONMENT - amendments.
Only the following portions of CHAPTER 12, INTERIOR ENVIRONMENT, are amended: (a) Section 1203.1, Equipment and systems, is amended to read as follows: 1203.1 Equipment and systems. Interior spaces intended for human occupancy shall be provided with heating per Section 1203.1.1 and cooling per Section 1203.1.2. 1203.1.1 Heating. Heating facilities shall be provided, capable of maintaining a room temperature of not less than 68°F (20°C) in all habitable rooms, bathrooms and toilet rooms, based on the winter design temperature of 34°F (01°C) for Phoenix, per Appendix D of the International Plumbing Code. Cooking appliances and portable space heaters shall not be used to achieve compliance with this section. Exceptions: Heating systems are not required for: 1. Interior spaces where the primary purpose of the space is not associated with human comfort. 2. Group F, H, S or U occupancies. 1203.1.2 Cooling. Cooling facilities shall be provided, capable of maintaining room temperature of not more than 85°F (29°C) in all habitable rooms, bathrooms and toilet rooms, based on the summer design temperature of 107°F (42°C) for Phoenix, per Appendix D of the International Plumbing Code. Exceptions: Cooling systems are not required for: 1. Interior spaces where the primary purpose of the space is not associated with human comfort. 2. Group F, H, S or U occupancies. (b) A new Section 1211, Sanitation, is added to read as follows: SECTION 1211 SANITATION 1211.1 Kitchen. Every dwelling unit shall be provided with a kitchen sink and counter/cabinet area. 1211.2 Trash disposal and recycling facilities. Every dwelling unit shall be provided with a kitchen cabinet pull-out compartment containing no fewer than two bins, each with a capacity of at least 7-gallons, for separation and collection of trash and recyclable materials. 1211.3 Trash and Recycling Chutes. Multifamily buildings 4 or more stories shall be provided with trash chute(s) and either recycling chute(s) or recycling collection area(s) on each floor. Mailrooms, breakrooms and common kitchen/kitchenette areas shall be provided with built-in or pull-out recycling containers. Space shall be allocated for central collection and storage of trash and recyclable materials until pick up.
(Ord. No. 4550, § 1(Res. No. 12498, § 1(Exh. A)), 9-20-22, eff. 1-1-23)
Ask a question about Scottsdale law
Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.