17.08.620 - New construction or substantial improvements.
A. The floodplain administrator shall review all building permit applications for new construction or substantial improvements of structures within the special flood hazard area. No flood clearance for a building permit shall be issued unless the floodplain administrator determines that the proposed construction, repair, reconstruction or improvement, including manufactured homes, if any are permitted, pursuant to Titles 19 and 20 of this Code meets all of the following requirements: 1. Is protected against flood damage; 2. Is adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic or hydrostatic loads, including the effect of buoyancy; 3. Uses construction materials and utility equipment that are resistant to flood damage; 4. Uses construction methods and practices that will minimize flood damage; 5. Uses electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; 6. If within Zones AH or AO as shown on the FIRM, has adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures; 7. Residential construction. Excepting residential construction in Zone A99, all new construction of any residential structure or substantial improvements of such a residential structure shall have the lowest floor, including basement, comply with all the requirements of Subsections A.1. through A.6. of this section and the requirements of the applicable flood hazard zone in Subsections A.7.a. and A.7.b. below. For residential structures, attached garages may be built at grade provided that such garages also meet the design requirements of Subsection A.10. of this section. All subgrade enclosed areas (except crawlspaces) are considered to be basements and are prohibited in residential structures. This prohibition includes below-grade parking garages and below-grade storage areas. a. Zone AO. Elevated to or above the depth number specified on the FIRM. If there is no depth number on the FIRM, the lowest floor, including basement, shall be elevated two feet above the highest adjacent grade. Upon completion of the structure, the floodplain administrator or a registered professional engineer or surveyor shall certify that the structure is elevated as set forth in this subsection and, if certified by a professional engineer or surveyor, shall provide such certification to the floodplain administrator as set forth in Section 17.08.560. b. Zones A, A1-A30, AE or AH. Elevated to or above the base flood elevation specified on the FIRM or the best available data as defined in Section 17.08.210 when base flood elevation has not been provided. Upon completion of the structure, the elevation on the required vertical datum showing the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor and provided to the floodplain administrator as set forth in Section 17.08.560. 8. Nonresidential and mixed-use construction. Excepting nonresidential and mixed-use construction in Zone A99, all new construction of any nonresidential or mixed-use structure or substantial improvements of such structures shall comply with all the requirements of Subsections A.1. through A.6. above and be in conformance with the elevation requirements of the applicable flood hazard zone or the alternative flood hazard requirement as specified below: a. Zone AO. Elevated to or above the depth number specified on the FIRM. If there is no depth number on the FIRM, the lowest floor, including basement, shall be elevated two feet above the highest adjacent grade. Access to residential uses of mixed use structures shall be dry floodproofed. Upon completion of the structure, the floodplain administrator or a registered professional engineer or surveyor shall certify that the structure is elevated as set forth in this subsection and, if certified by a professional engineer or surveyor, shall provide such certification to the floodplain administrator as set forth in Section 17.08.560. b. Zones A, A1-A30, AE or AH. Elevated to or above the base flood elevation specified on the FIRM or the best available data as defined in Section 17.08.410 when base flood elevation has not been provided. Access to residential uses of mixed use structures shall be dry floodproofed. Upon completion of the structure, the elevation on the required vertical datum showing the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor and provided to the Floodplain administrator as set forth in Section 17.08.560. c. Alternative flood hazard requirement. With attendant utility and sanitary facilities: i. Be dry floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water; ii. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and iii. Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certification shall be provided to the floodplain administrator as set forth in Section 17.08.560; 9. Zone A99 construction. The Zone A99 flood hazard areas are designated by a Federal Emergency Management Agency (FEMA) letter of map revision. These areas have received additional flood protection due to the construction of improvements such as dikes, dams or levees. No base flood elevation has been designated for Zone A99. The requirements of Subsections A.1. through A.5. of this section and Section 17.08.640 do not apply to the Zone A99 flood hazard area. For new construction and substantial improvements in Zone A99, the permit applicant shall be provided a written notice of the flood risk in a form acceptable to the city attorney. All property owners shall acknowledge the receipt of the written notice and acknowledge in writing that they do not elect to voluntarily comply with the requirements of Subsections A.1. through A.5. of this section and Section 17.08.640. 10. Enclosed areas below the lowest floor. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or limited storage, and which are subject to flooding, shall be designed to provide wet floodproofing and shall automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood water. Designs for meeting this requirement must meet or exceed the following minimum criteria: a. Be certified by a registered professional engineer or architect; or b. Have a minimum of two openings having a total net area of not less than one square inch for every one square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of flood water. 11. Crawlspace construction. All crawlspaces shall comply with all the requirements of Subsections A.2. through A.5. of this section and the design requirements of Subsection A.10. of this section. Below-grade crawlspaces for new construction and substantial improvements shall be designed and certified by a registered professional engineer to meet the following additional requirements: a. The interior grade of the crawlspace below the base flood elevation must not be more than two feet below the lowest adjacent exterior grade; b. The height of the below-grade crawlspace, measured from the interior grade of the crawlspace to the top of the crawlspace foundation wall, must not exceed four feet at any point; c. The velocity of flood waters at the parcel or site should not exceed five feet per second; d. There must be an adequate drainage system that removes flood waters from the enclosed interior area of the crawlspace within a reasonable amount of time, not to exceed seventy-two hours after the end of a flood event. The drainage system may include natural drainage through porous, well-drained soils, or drainage systems such as perforated pipes, drainage tiles, or gravel or crushed stone drainage by gravity or mechanical means. e. Below-grade crawlspace construction in accordance with the requirements listed above will not be considered basements. However, applicants who construct structures that have below- grade crawlspaces are hereby advised that such structures will have higher flood insurance premiums than structures that have crawlspaces with interior elevations at or above the lowest adjacent exterior grade. 12. Accessory structures. An exemption to the elevation or dry floodproofing standards may be granted for accessory structures used solely for parking (residential garages with gross floor area of six hundred fifty square feet or smaller) or limited storage (low-cost sheds with gross floor area of two hundred square feet or smaller). Such structures shall not be used for human habitation and must meet the requirements of Subsections A.2. through A.6., inclusive, the design requirements of Subsection A.10. of this section, and the encroachment provisions of Section 17.08.640D. Portions of the structure with uses other than parking and limited storage must meet the elevation requirements of the applicable special flood hazard zone in Subsection A.7. of this section. 13. Manufactured homes. Manufactured homes shall meet the above standards and also the standards in Sections 17.08.640 and 17.08.650. 14. Coastal high hazard areas. Within coastal high hazard areas, Zone V, V1-V30, and VE, as established under Section 17.08.510, the following standards shall apply: a. All new residential and nonresidential construction, including substantial improvement/damage, shall be elevated on adequately anchored pilings or columns and securely anchored to such pilings or columns so that the bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the base flood level. The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading values used shall be those associated with the base flood. Wind loading values used shall be those required by applicable state or local building standards. b. All new construction and other development shall be located on the landward side of the reach of mean high tide. c. All new construction and substantial improvement shall have the space below the lowest floor free of obstructions or constructed with breakaway walls as defined in Part 2 of this ordinance. Such enclosed space shall not be used for human habitation and will be usable solely for parking of vehicles, building access or storage. d. Fill shall not be used for structural support for buildings. e. Man-made alteration of sand dunes which would increase potential flood damage is prohibited. f. The Floodplain Administrator shall obtain and maintain the following records: i. Certification by a registered engineer or architect that a proposed structure complies with Section 17.08.620A.14.a.; and ii. The elevation (in relation to mean sea level) of the bottom of the lowest horizontal structural member of the lowest floor (excluding pilings or columns) of all new and substantially improved structures, and whether structures contain a basement. B. In making said determination, the floodplain administrator shall review and reasonably utilize any base flood elevation data available, principally the FIRM, which has been provided by the administrator. The applicant for a permit hereunder shall present drawings, plans, specifications, a certificate of elevation, and any other data or information which the floodplain administrator may require.
(Ord. 28512.)
Ask a question about San Jose law
Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.