Use and handling of explosives.
Round Rock Code of Ordinances § 16-152
in effectSec. 16-152. - Use and handling of explosives.
(a) Blasting operations. Blasting operations shall be conducted during daylight hours except when authorized at other times by the city engineer.
(b) Who may handle and fire explosives. The handling and firing of explosives shall only be performed by the person possessing a valid explosives certificate issued by the city engineer, or by employees under his direct personal supervision who are at least 18 years of age.
(c) Handling while under the influence of drugs and intoxicants prohibited. No person shall handle explosives while under the influence of intoxicants or narcotics.
(d) Smoking prohibited. No person shall smoke or carry matches while handling explosives or while in the vicinity thereof. No smoking signs shall be posted in areas where explosives are being handled. The signs shall be visible for at least 25 feet.
(e) Open flame light prohibited. No open flame light shall be used in the vicinity of explosives.
(f) Utilities to be notified in advance of blasting. Whenever blasting is being conducted in the vicinity of gas, electric, water, fire alarm, telephone, telegraph or steam utilities, the blaster shall notify the appropriate representative of such utilities at least 24 hours in advance of blasting, specifying the location and intended time of such blasting. In an emergency, this time limit may be waived by the city engineer.
(g) Conduct of blasting. Blasting operations shall be conducted in accordance with nationally recognized good practice.
(h) Pre-blast precautions. Before a blast is fired, the person in charge shall make certain that all surplus explosives are in a safe place, all persons and vehicles are at a safe distance or under sufficient cover, and a loud warning signal has been sounded.
(i) Precautions against accidental discharge. Due precautions shall be taken to prevent accidental discharge of electric blasting caps from current induced by radio or radar transmitters, lightning, adjacent power lines, dust storms, or other sources of extraneous electricity. These precautions shall include:
(1) The suspension of all blasting operations and removal of persons from the blasting area during the approach and progress of an electrical storm.
(2) The posting of signs warning against the use of mobile radio transmitters on all roads within 350 feet of the blasting operations.
(3) Compliance with nationally recognized good practice when blasting within 1½ miles of broadcast or high-power short wave transmitters.
(j) When adequate blasting mat required. When blasting is done in a congested area or in close proximity to a building, structure, railway, highway, or any other installation that may be damaged by material being thrown into the air, the blast shall be covered with an adequate blasting mat. Proof that any such building, structure, railway, highway, vehicle, conveyance, or other installation was damaged to any degree by material which was so thrown into the air shall raise a rebuttable presumption that said blast was not covered with an adequate blasting mat. For purposes of this subsection, an otherwise adequate blasting mat used improperly shall not be considered to be an adequate blasting mat.
(k) Tools. Tools used for opening packages of explosives shall be constructed of non-sparking materials.
(l) Packing materials to be disposed of. Empty boxes and paper and fiber packing materials which have previously contained high explosives shall not be used again for any purpose, but shall be disposed of in a manner approved by the city engineer.
(m) Explosives not to be abandoned. Explosives shall not be abandoned.
(n) Exposed blasting cap lead wires. All exposed blasting cap lead wires in the ground from previous shots shall be removed at the end of the work day.
(o) Particle velocities. Particle velocities shall not exceed the safe levels indicated in figure A below and in no case shall particle velocities exceed 1.7 inches per second. Monitoring of particle velocities for all blasting operations shall be carried out as outlined in this section. When particle velocities exceed 0.5 inches per second, blast frequencies in excess of the safe limits specified herein will require the immediate suspension of blasting and procedures to correct the excess velocity or frequency. The city engineer or his designate may grant or require variances from this limit as required to adequately protect the public safety. Air over pressures shall not exceed 129 decibels on five-sixths hertz high pass monitoring system.
FIGURE A
[image omitted; see the official code]
Safe Levels of blasting vibration using a combination of velocity and displacement.
(p) Blast monitors. Blast monitors, such as a seismic blast recording machine, are required for all blasting operations for which a permit is issued by the city unless specifically exempted by the city engineer or his designate. Blast monitors may be inspected by the city engineer or his designate. Frequency and air over pressures need not be monitored until six months after the effective date of the ordinance from which this section was derived unless specifically required by the city engineer or his designate.
(q) Monitoring technician. Monitoring technicians, not employed by a blasting operator, shall be used whenever a blast monitor is required. Monitoring technicians shall be trained in proper placement of monitor sensors and proper functioning of the instrument to be used. All monitoring reports shall carry the seal of a state professional engineer indicating the accuracy and validity of such reports.
(r) Blasting trunk wire. Blasting trunk wire of 18-gauge minimum shall be used while conducting blasting operations under permits.
(s) Approved blasting machines. Approved blasting machines shall be used. All other equipment is prohibited.
(t) Detonating cord. Detonating cord may be used only when approved on the blasting permit. Unauthorized use of detonating cord shall result in the temporary suspension of the blasting permit and/or blaster's license.
(u) Other conditions set by city engineer or his designate. Other conditions may be set by city engineer or his designate for the approval of a permit application that are necessary, in his opinion, to adequately protect the public health and safety. These conditions may include, but are not limited to, reduced allowable particle velocities, additional monitoring, increased insurance protection, hours of operation, type and amount of explosives used and engineered blasting plans.
(v) No blasting on Sundays, legal holidays, or between 5:00 p.m. and 8:00 a.m. Except with written approval, no blasting shall be done on Sundays, legal holidays, or between the hours of 5:00 p.m. and 8:00 a.m.
(w) Pre-blast notification. All blasting operations shall be preceded by a pre-blast notification to the owners or managers of all affected premises. The range of the pre-blast notification shall be at the discretion of the blaster or as required by the permit.
(Code 1995, § 5.213; Ord. No. 550, 8-10-1978; Ord. No. 2330, 3-24-1988)
Source: City of Round Rock, Texas, Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/tx/round_rock/codes/code_of_ordinances?nodeId=PTIICOOR_CH16FIPRPR_ARTVIEX_S16-152USHAEXFetched: 11/16/2026