Standards of performance for new sources.
40 C.F.R. § 421.144
in effectAny new source subject to this subpart shall achieve the following new source performance standards:
(a) Sodium Antimonate Autoclave Wastewater.
NSPS for the Primary Antimony Subcategory
Pollutant or pollutant property
Maximum for any 1 day
Maximum for monthly average
mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product
Antimony30.15013.440
Arsenic21.7209.687
Mercury2.3440.937
Total suspended solids234.400187.500
pH(
1)(
1)
1 Within the range of 7.5 to 10.0 at all times.
(b) Fouled Anolyte.
NSPS for the Primary Antimony Subcategory
Pollutant or pollutant property
Maximum for any 1 day
Maximum for monthly average
mg/kg (pounds per million pounds) of antimony metal produced by electrowinning
Antimony30.15013.440
Arsenic21.7209.687
Mercury2.3440.937
Total suspended solids234.400187.500
pH(
1)(
1)
1 Within the range of 7.5 to 10.0 at all times.
(c) Cathode Antimony Wash Water.
NSPS for the Primary Antimony Subcategory
Pollutant or pollutant property
Maximum for any 1 day
Maximum for monthly average
mg/kg (pounds per million pounds) of antimony metal produced by electrowinning
Antimony60.31026.870
Arsenic43.43019.370
Mercury4.6871.875
Total suspended solids468.700375.000
pH(
1)(
1)
1 Within the range of 7.5 to 10.0 at all times.