Sec. 22-229. - Amendment.
The housing code adopted by provisions of this article is hereby amended as follows:
108.5 Fee Refunds is hereby repealed in its entirety.
Section 112 Means of Appeal is hereby appealed in its entirety. A person shall have the right to appeal a decision of the code official such person must prescribe to section 22-68.
Section R302 Fire Resistant Construction.
Table R302.1(2) Exterior Walls—Dwellings with fire sprinklers. Minimum wall fire separation distance shall be equal to lesser setbacks, but in no event less than 3 feet. No exceptions allowed.
R302.2 Townhouses. Each townhouse shall be considered a separate building and shall be separated by fire-resistance rated wall assemblies meeting the requirements of Section R302.1 for exterior walls.
Exception: A common 2-hour fire-resistance-rated wall assembly tested in accordance with ASTM E 119 or UL 263 is permitted for townhouses if such walls do not contain plumbing or mechanical equipment, ducts, or vents in the cavity of the common wall. This rating may be reduced to 1-hour when the townhouses on both sides of such wall are equipped throughout with an automatic sprinkler installed in accordance with NFPA 13D. The wall shall be rated for fire exposure from both sides and shall extend to and be tight against exterior wall and tight against the underside of the roof sheathing. Electrical installations shall be installed in accordance with Chapters 34 through 43. Penetrations of electrical outlet boxes shall be in accordance with Section R302.4.
302.2.6 Each individual townhouse shall be structurally independent.
Exceptions:
Townhouses separated by a common 2 hour wall as provided in Section 302.2.
R302.5.1 Opening protection. Openings from private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid doors not less than 1⅜ inches (35 mm) thick, or 20 minute fire rated doors.
Section R309 Automatic Fire Sprinkler Systems.
R309.1 Townhouse automatic fire sprinkler systems. An automatic residential fire sprinkler system shall be optional and not mandatory in townhouses.
R309.2 One- and two-family dwellings automatic residential fire sprinkler systems. An automatic residential fire sprinkler system shall be optional and not mandatory in one- and two-family dwellings.
R309.2[.1] Design an installation. When installed automatic residential fire sprinkler systems for one- and two-family dwellings and townhouses shall be designed and installed in accordance with NFPA 13D.
Section R502 Wood Floor Framing.
R502.12.4 Truss design drawing. Truss design drawings, prepared in compliance with Section R502.11.1, shall be provided to the building official at the time of inspection, rather at the undefined time prior to installation. The truss design drawings will be required to be provided with the shipment of trusses and be available on the construction site for review by inspector before installation.
Chapter 11 Energy Efficiency.
Chapter 11 Energy Efficiency. Chapter 11 of the International Residential Code for One- and Two-Family Dwellings, 2024 edition is deleted and replaced with Chapter 11 of the International Residential Code for One- and Two-Family Dwellings, 2006 edition.
P2904.1.1 Required sprinkler locations.
When installed the sprinklers shall protect all areas of a dwelling unit.
E3401.1—E4209.6 The City of Oxford prohibits the use of aluminum conductors in branch circuits as allowed in 2024 IRC for One- and Two-Family Dwellings.
(Ord. No. 2025-4, § I, 6-3-2025)