Sec. 49-271. - Minimum protection requirements.
(a) Walkway required. A walkway not less than four (4) feet wide, with a railing on the street side shall be maintained on the sidewalk in front of the building site during construction or demolition work.
(b) Type of protection required:
(1) Protection shall be provided for pedestrians and property on the public property in accordance with the following minimum requirements:
_____
Table I
Minimum Protection Requirements
Height of Construction | Distance from Construction to Walkway | Protection Required
Eight feet or less | Less than six feet | Railing
Six feet or more | None
Less than six feet | Fence and canopy
More than eight feet | Six feet or more and one quarter height of construction or less | Fence and canopy
Six feet or more and one-fourth to one-half height of construction | Fence
Six feet or more and at least one-half height of construction | None
_____
(2) Such protection shall be maintained in place and kept in good order for the entire length of time pedestrians on the public property abutting the building site may be endangered and shall be completely removed as soon as the status of the work permits.
(c) Railings. Railings shall be substantially built to a height not less than three (3) feet.
(d) Fences and barricades:
(1) Solid fences or barricades shall be substantially built to a height not less than eight (8) feet above grade, placed on the side of the walkway nearest to the construction or demolition work.
(2) Fences or barricades shall extend the entire length of the building site, and each end shall be turned and extended to the building line.
(3) Doorways may be cut in such fences or barricades to provide ingress and egress, provided, however, that such doorways shall be protected by sturdy doors which are kept closed when not in use.
(e) Protective canopies:
(1) The protective canopy or barricade roof shall have a height of not less than eight (8) feet above the walkway.
(2) Such roof shall be leakproof and shall have a fence built along its entire length on the side next to the building site.
(3) The fence shall be solid from the sidewalk or walkway to the canopy roof, and each end shall be turned and extended solid to the building line.
(4) The entire structure shall be designed to carry the live and dead loads to be imposed on it; provided, that every such structure shall be designed to carry a minimum live load of not less than thirty-five (35) pounds per square foot, uniformly loaded.
(5) If materials are placed or stored or work is done upon the canopy or barricade roof, the street sides and ends of the canopy or barricade roof shall be protected by a tight curb board not less than one (1) foot high and a railing not less than three (3) feet high.
(6) The space under the canopy or barricade roof over the walkway and the approaches thereto shall be kept well lighted with artificial lighting continuously between sunset and sunrise.
(f) Increased protection. The manager of transportation and infrastructure may, as a condition of the granting of any permit for the erection of walkways, barricades, canopies, railings or fences, require heights, widths, distances or specifications greater than those provided in this section, if reasonably necessary for the protection of the public in the use of public ways and places.
(Code 1950, § 337.6; Ord. No. 39-20, § 112, 2-3-20)