§ 5-4-17 — Installation standards—Generally

Code of Ordinances, City of Biloxi, Mississippi (Supp. No. 63, Update 1: codified through Ordinance No. 2607, enacted July 28, 2026) · Biloxi Code of Ordinances § 5-4-17

Corpus is an independent public-information project, not the official City of Biloxi website. Stable reference: corpuslaw.us/code/feb473f3-871d-45ae-91cf-558acd33901e

Sec. 5-4-17. - Installation standards—Generally.

(a) All electrical installations shall be in conformity with the provisions of this article and the statutes of the state, and shall be in conformity with the approved standards for safety to life and property. In every case when no specific type or class of material or no specific standards are prescribed by the statues of the state, by regulations issued under the authority of the state statutes or by this article, conformity with the regulations as laid down in the latest edition of the National Electrical Code, as approved by the American National Standards Institute, shall be prima facie evidence of conformity with approved standards for safety to life and property. (b) All commercial buildings will be wired in metal galvanized rigid conduit, electric metallic tube (EMT) or polyvinyl chloride (PVC) conduit, except, in changes of occupancy of existing structures, nonmetallic sheathed cable (Romex) may be allowed if it meets the standards of the National Electrical Code and other requirements of this article. EXCEPTION: Apartment houses that do not exceed three stories in height, and are used solely for residential purposes, may be wired in Romex. This exception does not include apartments used for short-term rentals. (c) All conduits shall have separate bond ground wires. Ground wires shall be green in color. (d) All buildings or structures with service of less than 800 amperes shall provide a service disconnect at a readily accessible location on the outside of the building or structure. The service disconnect shall consist of not more than six switches or six circuit breakers mounted in a single enclosure or in a switchboard. No one service shall have more than six disconnects in any one location. The service disconnect shall be permanently marked to identify it as a "service disconnect". (e) Buildings or structures with a service of 800 amperes or more may have the service disconnect located inside the building or structure. The service disconnect shall not be more than three feet from the point of entrance and the disconnect shall be equipped with a shunt trip device. The shunt trip button shall be located next to the service metering equipment and shall be permanently marked as to its purpose. All optional or emergency standby systems shall have a permanent sign placed at the service-entrance equipment indicating type and location of on-site standby power sources. (f) All electrical nonmetallic tubing shall comply with article 362 of the National Electrical Code. No electrical nonmetallic tubing shall be used for exposed work. Any electrical nonmetallic tubing shall not be larger than one-inch electrical trade size. Electrical nonmetallic tubing shall not be used in any building or structure over one story in height.

(Code 1959, § 6-52; Ord. No. 1701, § 1, 11-16-93; Ord. No. 1801, § 1, 4-30-96; Ord. No. 2030, § 10, 3-21-06; Ord. No. 2418, § 3, 3-24-2020)

Ask a question about Biloxi law

Corpus searches the Biloxi sections it holds and shows the ones that match, with their citations. Free, no sign-in.