§ 25-2406 — Park standards
Fargo Municipal Code, Fargo, North Dakota (Supp. No. 14, Update 5: codified through Ordinance No. 5555, adopted August 17, 2026) · Fargo Municipal Code § 25-2406
Corpus is an independent public-information project, not the official City of Fargo website. Stable reference: corpuslaw.us/code/ffd88e6c-5228-405d-95d2-4682df2dc9af
25-2406. - Park standards.
In addition to the standards located in Section 20-0207 of Chapter 20 of the Fargo Municipal Code, each mobile home park or community shall comply with the following: A. The limits of each mobile home lot must be marked or clearly defined on the ground. The lot limits must be the same as shown on accepted plans. B. The mobile home stand must be improved to provide adequate support for placement. The stand may not heave, shift or settle unevenly under the weight of the mobile home due to inadequate drainage. The stand must be graded to provide drainage away from the stand. Permanent foundations shall comply with the requirements of the city building code. C. Mobile homes and attachments must be separated from each other and from other principal buildings or structures on adjacent lots in the community by at least fifteen feet. D. All streets within a mobile home community must be hard-surfaced and shall comply with the city zoning ordinances. All streets shall be maintained in good condition. E. The connection of water, fuel, sanitary sewer and electrical service must be under the supervision of the mobile home community owner or operator or a qualified representative of the utility company supplying fuel or electrical service. A mobile home may not be occupied before an inspection is conducted by the building official of the following items to insure ordinance compliance: 1. Water and sanitary sewer connections; 2. The electrical service conductors; 3. The placement of the home to insure sideyard and setback requirements; 4. A gas line test conducted by the owner or seller of the mobile home unit and certified by the building official; 5. Heating appliances for transportation damages; 6. Blocking to approved standards; 7. The home is secured by approved tie-downs to the stand. F. Each new or altered mobile home lot must be provided with service equipment rated at not less than 100 amperes. Provisions may be made for connecting a mobile home power supply assembly by a permanent wiring method which may have 50-ampere receptacles conforming to the National Electrical Code. Each existing mobile home lot must be provided with an electrical service of adequate size to serve the mobile home load. G. Fuel supply. 1. Gas equipment and installation within a mobile home community must be designed and constructed in accordance with the provisions of the International Fuel Gas Code, as adopted by the city. Each lot must be provided with an accessible, listed gas shutoff valve. The valve may not be located under the mobile home. The connector between the gas supply line and the mobile home must be an approved listed flexible mobile home connector of sufficient capacity to supply gas to the connected load. 2. Fuel oil equipment and supply must be designed and installed in accordance with the International Fuel Gas Code and the International Fire Code, as adopted by the city. H. A mobile home community must be provided with an adequate supply of potable water complying with the state health department standards for drinking and domestic use. I. Each mobile home lot must be provided with sanitary sewer and water connections. Such plumbing facilities shall conform to the city's plumbing code. J. Any buildings housing toilet rooms and/or laundry facilities must be a permanent structure. The interior surfaces must be moisture resistant and readily cleanable. Such structures shall meet the requirements of the city building code. K. Accessory buildings. 1. Accessory buildings and carports must be of standard construction and shall meet the requirements of the city building code. An attached entryway may not obstruct any required exitway from the mobile home. No more than one entryway is allowed for each mobile home. The entryway is limited to a maximum of 120 square feet in size. A porch or deck that is open on at least two sides except for roof supports and guardrails need not be included in the allowable square footage of the attached entryway. 2. Individual storm shelters are permitted provided they meet the requirements of the city building code and the consent of the community manager has been obtained. Such shelters may not be included in lot coverage requirements of the zoning ordinances or be counted as an accessory building to the mobile home lot. 3. A detached garage may be allowed providing the following requirements are met: a) Garages must be located at least seven and one-half feet from the dividing line between mobile home lots. They shall be at least 15 feet from the mobile home or any attachment thereto on a neighboring lot. b) A minimum of six feet must be maintained between a garage and a mobile home or attachment thereto on the same lot. c) A 20-foot setback must be maintained between the front of the garage and any public or private street. d) The above setback and sideyard clearances apply unless a greater clearance is required by the zoning ordinances if the mobile home, attachment, or accessory buildings is located adjacent to a public right-of-way. These clearances must be to the walls of the structure involved; a roof overhang may extend a maximum of two feet into the setback or sideyard. e. Accessory buildings on a mobile home lot are limited to one attached entryway not to exceed 120 square feet, one detached storage or utility building not to exceed 120 square feet, and one detached garage as specified in this section. f. Carports may not project beyond the front or rear edge of the mobile home. Carports must be set back a minimum of 20 feet from the walkway, a minimum of seven and one-half feet from the lot line, and must be located at least 15 feet from any other mobile home and its attachments. g. Accessory structures must be attached to proper foundations. Exceptions to foundations may be granted by the building official provided the methods used shall render them rodent proof and resistant to wind damage. h. Accessory buildings may not be constructed without building permits. h. Accessory storage or utility structures shall comply with setback and sideyard requirements of the zoning ordinances.
Source: 4952 (2014).
Ask a question about Fargo law
Corpus searches the Fargo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
