For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-242 — Amendments

Code of Ordinances of the City of Fairbanks, Alaska (Codified through Ordinance No. 6332, effective December 21, 2025. (Supp. No. 36)) · Fairbanks Code of Ordinances § 10-242

Corpus is an independent public-information project, not the official City of Fairbanks website. Stable reference: corpuslaw.us/code/289e1e89-3b9c-4f2c-9708-a7167425dd0e

Sec. 10-242. - Amendments.

The ADA Accessibility Guidelines is hereby amended as follows: LOCAL AMENDMENTS TO THE ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES INCLUDING APPENDICES THERETO Americans With Disabilities Act of 1990 (ADA) 36 CFR 1191, published July 26, 1991 9.701.1 Amendments. 3.5 | Definitions 4.1.1 | Application (Minimum Requirements) 4.1.1.2 | Accessibility to Temporary or Permanent Buildings 4.1.2 | Accessible Sites and Exterior Facilities: New Construction 4.1.3 | Accessible Buildings - New Buildings 4.1.6 | Accessible Buildings - Alterations 4.3.10 | Egress 4.3.11 | Areas of Rescue Assistance 4.7 | Curb Ramps 4.11.2 | Other Requirements (Platform Lifts) 4.13.11 | Door Opening Force 4.14.1 | Minimum Number (Entrances) 4.16.4 | Grab Bars (Water Closets) 4.19.3 | Clear Floor Space (Lavatories) 4.20.4 | Grab Bars (Bathtubs) 4.21.2 | Size and Clearances (Shower Stalls) 4.21.4 | Grab Bars (Showers) 4.23.4 | Water Closets (Bath Rooms) 4.24.3 | Knee Clearance (Sinks) 4.24.5 | Clear Floor Space (Sinks) 4.27.2 | Clear Floor Space (Controls and Operating Mechanisms) 4.33.8 | Assistive Listening Systems Where Required 5.4 | Dining and Drinking Establishments 3.5 Definitions. Amend 3.5 as follows: Add the following definition: Adaptable: The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of either disabled or nondisabled persons, or to accommodate the needs of persons with different types or degrees of disability. 4.1.1 Application (Minimum Requirements). Amend section 4.1.1(1) and substitute as follows: (1) General. Buildings or portions of buildings shall be accessible to persons with disabilities, unless otherwise provided in this section or as modified in a special application section. Occupancy groups classified according to use or the character of occupancy shall be as defined in the Uniform Building Code. (a) Group A assembly occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. (b) Group B business occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35, and as follows: (c) Group E educational occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. (d) Group F factory and industrial occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. (e) Group H hazardous occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. (f) Group I institutional occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. Group I, divisions 1.1 and 1.2 occupancies shall also comply with these guidelines, 6.1 through 6.4. Group I, division 2 occupancies shall also comply with these guidelines, 6.1 through 6.4. Group I, division 3 mental health occupancies shall also comply with these guidelines, 6.1 through 6.4. Group I, division 3 jail, prison and similar occupancies shall also have at least five percent of rooms and cells, including associated toilet rooms and bathrooms, to comply with these guidelines, 6.3 through 6.4. (g) Group M mercantile occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. (h) Group R residential occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. Group R, division 1 hotels, motels, inns, boardinghouses, dormitories, resorts and other similar places of transient (less than 30 days) lodging shall also be accessible to comply with these guidelines, 9.1 through 9.5. Group R, division 1 apartment houses (multifamily housing of primarily permanent residence) with more than three dwelling units shall be accessible to comply with these guidelines, 4.1 through 4.35. EXCEPTIONS: 1. Dwelling units within apartment houses required to be accessible may be adaptable dwelling units. 2. Dwelling units within apartment houses located on floors other than the primary entry level when no elevator is provided within the building. 3. Individual dwelling units of two or more stories within apartment houses. Group R, division 3, dwellings containing not more than three dwelling units and lodginghouses containing not more than five guest rooms need not be accessible. Group R, division 1, congregate residences shall be accessible to comply with these guidelines, 4.1 through 4.35 and shall have at least two percent, but not less than one of the sleeping rooms and associated toilet rooms and bathrooms accessible to comply with these guidelines, 9.1 through 9.5. (i) Group S storage occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. (j) Group U utility occupancies shall be accessible to comply with these guidelines, 4.1 through 4.35. 4.1.1.2. Add a new subsection 4.1.1.2: Accessibility to Temporary or Permanent Buildings. Accessibility to temporary or permanent buildings or portions thereof shall be provided for all occupancy classifications except as modified by 4.1.1. Exceptions: 1. Floors or portions of floors not customarily occupied, including but not limited to, elevator penthouses; nonoccupiable spaces accessed only by ladders, catwalks, crawl spaces or freight elevators; piping and equipment catwalks; and machinery, mechanical and electrical equipment rooms. 2. Subject to the approval of the building official, areas where work cannot reasonably be performed by persons having a severe impairment (mobility, sight or hearing) need not have specific features which provide accessibility to such persons. 3. Temporary structures, sites and equipment directly associated with the construction process such as construction-site trailers, scaffolding, bridging or material hoists are not required to be accessible. This exception does not include walkways or pedestrian protection. 4.1.2 Accessible Sites and Exterior Facilities: New Construction. Amend 4.1.2 as follows: Delete entire subsection (5)(e). 4.1.3 Accessible Buildings: New Buildings. Amend 4.1.3 as follows: Amend subparagraph (8) as follows: Delete entirely subparagraph (a)(ii); substitute as follows: (a) (ii) Accessible entrances must be provided in a number at least equivalent to the number of exits required by chapter 10 of the Uniform Building Code. Delete entirely subparagraph (9); substitute as follows: (9) In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required by chapter 10 of the Uniform Building Code. Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in a number equal to that of inaccessible required exits). Areas of rescue assistance shall comply with 4.3.11. A horizontal exit meeting the requirements of section 1008 of the Uniform Building Code shall satisfy the requirements of an area of rescue assistance. EXCEPTION: Areas of rescue assistance are not required in buildings or facilities having a supervised automatic sprinkler system. (16) Add a new subsection to section 4.1.3(16)(c): (c) Building directories are required for the following occupancies as defined by the building code: groups A, B, E, I, and M greater than 6,000 square feet or more than one story. Regardless of building size, directories shall be provided for governmental office buildings, medical care facilities, shopping malls, public transportation facilities, senior citizen housing and hotels. Directories shall be provided within or immediately adjacent to the main entrances as approved by the building official. Directory signage shall comply with 4.30.2 and 4.30.5. Letters or characters shall be at least five-eighths inch high. (17) Add two (2) new sentences to 4.1.3 public telephones (17)(a): (a) Regardless public telephones are required in medical care facilities, governmental office buildings, shopping malls, public and private schools, hotels, convention centers, and shall be located on an accessible route. (For the purpose of this section schools which meet the group E, division 1 occupancy classification as defined in chapter 3 of the Building Code shall comply.) (17) Section 4.1.3 Public Telephones (17)(c)(ii). Delete (17)(c)(ii) in its entirety; Replace with the following: (c) (ii) A text telephone is required in governmental office buildings including police and fire stations, medical care facilities, senior housing facilities, hotels, conventions centers, libraries, public and private schools and shopping malls. (For the purpose of this section schools which meet the group E, division 1 occupancy classification as defined in chapter 3 of the Building Code shall comply.) (17) Section 4.1.3 17 Public Telephones (c)(iii). Delete in its entirety. Replace with the following: (c) (iii) A public text telephone is required in or adjacent to a hospital emergency room or hospital waiting room, and shall be located on an accessible route. 4.1.6 Accessible Buildings: Alterations. Amend 4.1.6 as follows: Delete entirely subparagraph (2); substitute as follows: (2) Alteration to an Area Containing a Primary Function. In addition to the requirements of 4.1.6(1), an alteration that affects or could affect the usability of or access to an area containing a primary function shall be made so as to ensure that, to the maximum extent feasible, the path of travel to the altered area and the restrooms, telephones, and drinking fountains serving the altered area, are readily accessible to and usable by individuals with disabilities, unless such alterations are disproportionate to the overall operations in terms of cost and scope. For the purposes of this section, disproportionate cost and scope include but are not limited to: (a) Situations where alterations to provide the minimum requirements for accessibility are not feasible due to spatial limitations including but not limited to those caused by existing, load-bearing elements. (b) Situations where the cost of providing the requirements for accessibility, outside of the area to be altered in the building or structure, would exceed 25 percent of the cost of the alterations within the area to be altered in the building or structure. (c) Situations where the cost of the alterations within the area to be altered in the building or structure is less than $20,000.00. Amend subparagraph (3) as follows: section 4.1.6 Toilet Rooms (3)(e)(ii) delete in its entirety; replace with the following: (e) (ii) Where it is technically infeasible to install a required standard stall (fig. 30(a)), or where other codes prohibit reduction of the fixture count (i.e. removal of a water closet in order to create a double-wide stall), only the alternate stall which provides a 48-inch minimum width may be provided in lieu of the standard stall. Section 4.1.6(3)(g). Delete entirely subparagraph (g); replace with the following: (g) Platform Lifts (Wheelchair lifts). In alteration, platform lifts, (wheelchair lifts) complying with 4.11 and applicable state or local codes may be used as part of an accessible route. The use of lifts is not limited to the four conditions in exception 4 of 4.1.3(5). Platform lifts used in lieu of an elevator shall be capable of independent operation. 4.3.10 Egress. Delete entirely section 4.3.10; replace with the following: Accessible routes serving any accessible space or element shall also serve as a means of egress for emergencies or connect to an accessible area of rescue assistance. Means of egress including exterior exits shall be continuously maintained free of all obstructions or impediments to full instant use in case of fire or other emergency. 4.3.11 Areas of Rescue Assistance. Amend 4.3.11 as follows: Delete entirely paragraph 4.3.11.1; substitute as follows: 4.3.11.1 Location and Construction. An area of rescue assistance shall be one of the following: (1) A portion of a stairway landing within a smoke proof enclosure, complying with chapter 10 of the Uniform Building Code. (2) A portion of an exterior balcony located immediately adjacent to an exit stairway when the exterior balcony complies with chapter 10 of the Uniform Building Code. Openings to the interior of the building located within 20 feet (6 m) of the area of rescue assistance shall be protected with fire assemblies having a three-fourths-hour fire-protection rating. (3) A portion of a one-hour fire-resistive corridor complying with chapter 10 of the Uniform Building Code located immediately adjacent to an exit enclosure. (4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required by chapter 10 of the Uniform Building Code. (5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building by not less than one-hour fire-resistive door assemblies. (6) When approved by the building official, an area or room which is separated from other portions of the building by a smoke barrier. Smoke barriers shall have a fire-resistive rating of not less than one hour and shall completely enclose the area or room. Doors in the smoke barrier shall be tightfitting smoke- and draft-control assemblies having a fire protection rating of not less than 20 minutes and shall be self-closing or automatic closing. The area or room shall be provided with an exit directly to an exit enclosure. When the room or area exits into an exit enclosure which is required to be of more than one-hour fire-resistive construction, the room or area shall have the same fire-resistive construction, including the same opening protection, as required for the adjacent exit enclosure. (7) An elevator lobby complying with chapter 4 of the Uniform Building Code. Delete entirely paragraph 4.3.11.2; substitute as follows: 4.3.11.2 Size. Each area of rescue assistance shall provide at least two wheelchair (spaces that are) areas each being not less than 30 inches by 48 inches. Wheelchair spaces shall not be part of, nor encroach upon, any required exit/corridor/landing dimension. The area of rescue assistance shall not encroach on any required exit width. The total number of such 30-inch by 48-inch (760 mm by 1220 mm) wheelchair spaces, areas per story shall not be less than one for every 200 persons calculated occupant load served by the area of refuge based on a determination in accordance with chapter 10 of the Uniform Building Code. Delete entirely paragraph 4.3.11.2; substitute as follows: 4.3.11.4 Two-Way Communication. Two-way communication system, with both audible and visual signals, shall be provided between an area of rescue assistance and the principal entrance and a 24-hour manned central emergency control point. The department of public safety may approve a location other than the principal entrance. Where telephone handsets are provided as one means of communication, they shall comply with 4.31. 4.7 Curb Ramps. Amend figure 12(a) in section 4.7 by deleting the footnote and substituting as follows: If X (the distance from the upper edge of the ramp to any obstruction on the opposite edge of the sidewalk) is less than 48 inches, then the slope of the flared side shall not exceed 1:12. Amend figure 12(b) in section 4.7 by deleting the reference to "X." 4.11.2 Other Requirements (Wheelchair Lifts). Section 4.11.2 Platform Lifts. Delete 4.11.2 entirely; substitute in its place: If platform lifts (wheelchair lifts) are used, they shall comply with 4.2.4, 4.5, 4.27, section 509 UBC and the elevator code as adopted by the State of Alaska. Platforms shall be enclosed on all sides including gates. The enclosure shall be 42 inches high and shall be solid without openings. 4.13.11 Door Opening Force. Amend 4.13.11 as follows: Delete entirely 4.13.11 (2)(a); substitute as follows: (a) Exterior hinged doors: 8.5 lbf (37.8N). 4.14.1 Minimum Number (Entrances). Delete entirely 4.14.1; substitute as follows: 4.14.1 Minimum Number. Entrances required to be accessible by 4.1 shall be part of an accessible route and shall comply with 4.3. Such entrances shall be connected by an accessible route to accessible parking and passenger loading zones and to public streets or sidewalks if available (see 4.3.2(1)). They shall be connected by an accessible route to all accessible spaces or elements within the building or facility. 4.16.4 Grab Bars (Water Closets). Amend 4.16.4 as follows: Add a second paragraph to read as follows: EXCEPTION: Adaptable dwelling units shall have structural reinforcement or other provisions to allow installation of grab bars. 4.19.3 Clear Floor Space (Lavatories). Amend 4.19.3 as follows: Add a second paragraph to read as follows: EXCEPTION: If a cabinet is provided under the lavatory in an adaptable dwelling unit, then it shall be removable to provide the clearances specified in 4.19.2. 4.20.4 Grab Bars (Bathtubs). Amend 4.20.4 as follows: Add a second paragraph to read as follows: EXCEPTION: Adaptable dwelling units shall have structural reinforcement or other provisions to allow installation of grab bars. 4.21.2 Size and Clearances (Shower Stalls). Delete entirely 4.21.2; amend as follows: Size and Clearances. Shower stall size and clear floor space in group L institutional occupancies where required by 4.1.1(1)(f), in group R, division 1 apartment houses and congregate residences where required by 4.1.1(1)(h), shall comply with figure 35(a) or (b). Shower stall in figure 35(a) shall be 36 inches by 36 inches (915 mm by 915 mm). The shower stall in figure 35(b) will fit into the space required for a bathtub. Shower stall size and clear floor space in group R, division 1 hotels, where required by 4.1.1(1)(h), and 9.1.2 shall comply with figure 57(a) or 57(b). 4.21.4 Grab Bars (Showers). Amend 4.21.4 as follows: Add a second paragraph to read as follows: EXCEPTION: Adaptable dwelling units shall have structural reinforcement or other provisions to allow installation of grab bars. 4.23.4 Water Closets (Bathrooms). Amend 4.23.4 as follows: Add a second paragraph to read as follows: EXCEPTION: Adaptable dwelling units shall have structural reinforcement or other provisions to allow installation of grab bars. 4.24.3 Knee Clearance (Sinks). Amend 4.24.3 as follows: Add a second paragraph to read as follows: EXCEPTION: If a cabinet is provided under a kitchen sink in an adaptable dwelling unit, then it shall be removable to provide the knee clearance specified. 4.24.5 Clear Floor Space (Sinks). Amend 4.24.5 as follows: Add second and third paragraphs to read as follows: EXCEPTIONS: 1. In the kitchen of an adaptable dwelling unit, clear floor space shall be provided in front of a sink to allow parallel or forward approach. 2. If a cabinet is provided under a kitchen sink in an adaptable dwelling unit, then it shall be removable to provide the knee clearance specified in 4.24.3. 4.27.2 Clear Floor Space (Controls and Operating Mechanisms). Amend 4.27.2 as follows: Add a second paragraph to read as follows: EXCEPTION: In the kitchen of an adaptable dwelling unit, clear floor space shall be provided in front of an oven, dishwasher, refrigerator/freezer or trash compactor to allow parallel or forward approach. 4.29 Detectable Warnings. Delete this section in its entirety. 4.33.8 Add a new section: Assistive Listening Systems. Assistive listening systems where required. Assistive listening systems shall be installed in stadiums, theaters, auditoriums, lecture halls and similar areas where audible communications are integral to the use of the space as follows: 1. Areas with an occupant load of 50 or more. 2. Areas where an audio-amplification system is installed. Receivers for assistive listening systems shall be provided at a rate of four percent of the total occupant load, but in no case less than two receivers. Stadiums, theaters, auditoriums, lecture halls and similar areas not equipped with an audio-amplification system or having an occupant load of less than 50 shall have a permanently installed assistive listening system, or shall have electrical outlets or other supplementary wiring necessary to support a portable assistive listening system. Signage shall be installed to notify patrons of the availability of the listening system. Group B occupancies—Assembly spaces in group B occupancies shall comply with section 4.33.8. Group E occupancies—Assembly spaces in group E occupancies shall comply with section 4.33.8. Group M occupancies—Assembly spaces in group M occupancies shall comply with section 4. 5.4. Delete section in its entirety. Replace with the following: Dining and Drinking Establishments. In the assembly area of dining and drinking establishments which are located within nonelevator buildings, when the area of the mezzanine seating is not more than 33 percent of the total accessible floor area, an accessible means of vertical access to the mezzanine is not required, provided the same services are provided in an accessible space. (For the purpose of this section, mezzanine shall be as defined by UBC section 214 and section 507.) Raised, recessed floors or platforms shall be accessible.

(Code 1960, § 9.701.1)

Ask a question about Fairbanks law

Corpus searches the Fairbanks sections it holds and shows the ones that match, with their citations. Free, no sign-in.