§ 10-347 — Amendments
Code of Ordinances of the City of Fairbanks, Alaska (Codified through Ordinance No. 6332, effective December 21, 2025. (Supp. No. 36)) · Fairbanks Code of Ordinances § 10-347
Corpus is an independent public-information project, not the official City of Fairbanks website. Stable reference: corpuslaw.us/code/47fbc81f-37f9-4e8d-afb4-e87ac960f9ca
Sec. 10-347. - Amendments.
The State of Alaska Building Energy Efficiency Standard is amended as follows: Chapter 1. 1.2 Purpose. Delete this section in its entirety and replace with the following: The purpose of this standard is to regulate the design and construction of the exterior envelopes for the purpose of effective conservation of energy within a residential building as governed by the 1994 Uniform Building Code. A residential building shall be as defined by section 310.1 of the 1994 Uniform Building Code. 1.3 Policies. Delete in its entirety. 1.5 Compliance Methods. Amend this section by adding a new paragraph as follows: Fairbanks Prescriptive Method - Chapter 8. In order to obtain compliance with chapter 8, all local building code amendments, including local amendments to the State of Alaska Building Energy Efficiency Standard, shall be incorporated in the design and construction of a residential building. Compliance with chapter 8, Fairbanks Prescriptive Thermal Standards, shall be considered equivalent to the provisions set forth in the State of Alaska Building Energy Efficiency Standard. Compliance with the performance method (chapter 4) and the building budget method (chapter 5) shall be substantiated by calculations and a detailed plan review of thermal characteristics prepared by a licensed professional architect or engineer. 1.6 Alternate Materials and Construction Methods. Amend as follows: The provisions of this standard do not prevent the use of a material or method of construction not specifically prescribed by this standard provided the alternative has been approved and its use authorized as complying with this standard by the building official. For the purpose of this standard a complete and comprehensive design prepared by a licensed professional designer shall provide prima facie evidence of compliance with the intent of these provisions. The building official shall require that sufficient evidence or proof be submitted to substantiate any claims that may be made regarding alternatives. The details of any action granting approval of an alternate will be recorded and entered in the files of the building department. The following chapter is entirely new. Underlining and shading have been omitted for clarity. CHAPTER 8 FAIRBANKS PRESCRIPTIVE THERMAL STANDARD (This chapter represents a fifth method of compliance with these energy standards.) To comply with this method, the requirements of the Uniform Building Code and the Uniform Mechanical Code, as amended, must be considered in conjunction with the requirements to follow: (See amended UBC sections 1203.2, 1203.3, 2317.7, 1505.3 and UMC 301.0.) 8.1 Exterior Glazing. The total area of exterior glazed openings shall not exceed 12 percent of the floor area of the conditioned spaces. 8.2 Vapor Retarder. A. All exterior wall, ceiling, roof and floor assemblies which enclose heated spaces and which are exposed to outdoor ambient temperatures shall be protected against water vapor transmission. B. All such assemblies shall have installed, on the heated side of insulation or air spaces, an approved vapor retarder. The vapor retarder's shall be installed such that as a minimum 75 percent of the required R-value will be located on the cold side of the vapor retarder. C. An approved vapor retarder shall be a membrane with a minimum perm rating of 0.06 perm (equivalent to six mil. polyethylene sheeting). D. The vapor retarder shall be continuous and shall be installed to remain continuous for the lifetime of the structure. "Continuous" shall be defined as without penetrations, openings or holes, to the extent achievable using good workmanship. The vapor retarder shall be lapped a minimum of 24 inches or one framing member. 8.3 Domestic Water Heating. Compliance with this section can be achieved by any of the following options: A. DOMESTIC HOT WATER STORAGE TANKS. Domestic hot water storage tanks when installed in an unconditioned space shall be insulated to a minimum R-16 when the primary source of heating is electric. If the primary source of heating is nonelectric, a minimum R-10 insulation is required. Domestic hot water storage tanks when installed in a conditioned space shall be insulated to a minimum R-5 regardless of energy source. B. TANKLESS COILS. Tankless coils shall be installed in accordance with the manufacturer's instructions and recommendations to assure proper hot water flow restriction during normal usage. C. EXTERNAL TYPE SIDE-ARM WATER HEATERS. External type side-arm water heaters shall be insulated in accordance with option "A." 8.4 Thermal Envelope Requirements. The following minimum thermal envelope insulation requirements shall be provided to achieve compliance with the Fairbanks Prescriptive Thermal Standards described in this chapter: MINIMUM R-VALUE REQUIREMENTS Ceiling 1 | 38 Above Grade Wall | 21 Exposed Floor 2 | 38 Slab 3, 4 | 10 Windows | 3 Doors | 7 Rim Joist 5 | 19 Below Grade Wall 6 | 10 Footnotes: 1. Ceiling insulation may be reduced to R-30 over exterior wall top plates to accommodate differing roof design. 2. This shall not apply to floors over a conditioned or semi-conditioned space such as a crawl space. 3. Concrete slab-on-grade foundations with thickened perimeters shall not have insulation placed beneath the footing portion unless bearing upon entirely non-frost-susceptible soils. 4. Horizontally placed slab insulation shall be required only around the perimeter 24 inches. Slab insulation may be omitted if the foundation wall adjacent to such slab is fully insulated and a thermal break is provided between the foundation wall and the slab edge. 5. The rim joist area shall be insulated and sealed to prevent air infiltration. A continuous bead of flexible sealant is required between the floor sheathing and the top surface of the rim joist. A continuous bead of flexible sealant is also required between the sill plate and the bottom of the rim joist. Refer to typical standard foundation detail SFD-1. 6. The required insulation shall extend above grade such that insulation is provided for the entire vertical height of the foundation wall. The insulation shall be protected by an approved metal flashing. Refer to typical standard foundation detail SFD-1.
(Code 1960, § 9.1101.1)
Ask a question about Fairbanks law
Corpus searches the Fairbanks sections it holds and shows the ones that match, with their citations. Free, no sign-in.