15.08.050 - Section 10.6.1 amended—Watersewer pipe separation.
Section 10.6.1 of the plumbing code, as adopted by Section 15.08.010 is amended to read as follows: (a) Except as permitted in paragraph 10.6.2, the underground water-service pipe and the building drain or building sewer shall be not less than five feet (5′) apart horizontally and shall be separated by undisturbed or compacted earth. (b) When the building drain or the building sewer is above the water-service pipe, the pipe line separation, in addition to the five foot (5′) minimum horizontal separation, shall include an additional horizontal separation equal to twice the vertical difference between lines up to a total horizontal separation of ten feet (10′).
(Prior code § 10.10.100 (part)).