§ 15.28.160 — Coastal high hazard area
Municipal Code of the City of Kotzebue, Alaska (Codified through Ordinance No. 23-25, passed July 27, 2023. (Supp. No. 14)) · Kotzebue Municipal Code § 15.28.160
Corpus is an independent public-information project, not the official City of Kotzebue website. Stable reference: corpuslaw.us/code/7ffd4e1e-633e-40b9-b711-d636fed9e44a
15.28.160 - Coastal high hazard area.
Located within areas of special flood hazard established in Section 15.28.050 are coastal high hazard areas, designated as Zones V1-V30, VE and/or V. These areas have special flood hazards associated with high velocity waters from tidal surges and, therefore, in addition to meeting all provisions in this chapter, the following provisions shall also apply: A. All new construction and substantial improvements in Zones V1-V30 and VE (V if base flood elevation data is available) shall be elevated on pilings and columns so that: 1. The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the base flood level, and 2. The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Wind and water loading values shall each have one percent chance of being equalled or exceeded in any given year (100-year mean recurrence interval), A registered professional engineer or architect shall develop or review the structural design, specifications and plans for the construction and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of subsection A(1) and (2) of this section; B. Obtain the elevation (in relation to mean sea level) of the bottom of the lowest structural member of the lowest floor (excluding pilings and columns) of all new and substantially improved structures in Zones VI-30 and VE, and whether or not such structures contain a basement. The local administrator shall maintain a record of all such information; C. All new construction shall be located landward of the reach of mean high tide; D. Provide that all new construction and substantial improvements have the space below the lowest floor either free of obstruction or constructed with nonsupporting breakaway walls, open wood lattice-work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purposes of this section, a breakaway wall shall have a design safe loading resistance of not less than ten and no more than twenty pounds per square foot. Use of breakaway walls which exceed a design safe loading resistance of twenty pounds per square foot (either by design or when so required by local or state codes) may be permitted only if a registered professional engineer or architect certifies that the design proposed meet the following conditions: 1. Breakaway wall collapse shall result from a water load less than that which would occur during the base flood, and 2. The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (structural and nonstructural). Maximum wind and water loading values to be used in this determination shall each have a one percent change of being equalled or exceeded in any given year (100-year mean recurrence interval); E. If breakaway walls are utilized, such enclosed space shall be usable solely for parking of vehicles, building access, or storage. Such space shall not be used for human habitation; F. Prohibit the use of fill for structural support of buildings; G. Prohibit manmade alteration of sand dunes which would increase potential flood damage.
(Ord. 87-2 § 13, 1987: Ord. 83-13 § 5.3, 1983).
Ask a question about Kotzebue law
Corpus searches the Kotzebue sections it holds and shows the ones that match, with their citations. Free, no sign-in.
