9.15.111 - 2021 International Fire Code—Adopted.

A. The International Fire Code, 2021 Edition (IFC) Chapters 13-19, 41-49, 52, and 68-79 are reserved. The International Fire Code 2021 Edition (IFC), Chapters 1 - 12, 20 - 40, 50 - 51, 53-67, and 80 and Appendices B - I, K, L, and N as approved and published by the International Code Council, and adding appendix KK, except as provided in subsection D of this section, are adopted by reference, and hereby designated and shall be known as the Seward Fire Code and shall constitute a portion of the laws of the City relating to building regulation except to the extent that the International Building Code as adopted by the City shall be in conflict with this code or any relevant ordinance later adopted, in which case the provisions of the International Fire Code as adopted by the City shall prevail. B. The City of Seward shall possess three copies of the City designated edition of the International Fire Code, for public use, inspection and examination, so long as the provisions thereof remain in force: one copy is kept in the Seward City Library (239 Sixth Ave) and two sets are kept at the Seward Fire Station (316 Fourth Ave, Seward, AK 99664). C. Copies of the NFPA Standards may be obtained from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471 or at www.nfpa.org. D. Copies of the International Fire Code 2021 Edition (IFC) may be obtained from the International Code Council Inc., 900 Montclair Rd, Birmingham, Alabama 35213; Telephone: (888) 422-7233 or at www.iccsafe.org. E. It shall be unlawful for any person to erect, construct, enlarge, alter, repair, move, remove, convert, demolish, or equip any building or structure in the city, or cause or permit the same to be done, contrary to any provision of the International Fire Code adopted and incorporated as the Seward Fire Code by this section. F. The International Fire Code (IFC), 2021 Edition, adopted in Subsection A of this section is adopted by reference to regulate all occupancies and buildings for the safeguarding of life and property from the hazards of fire and explosion arising from the storage, handling, and use of hazardous substances, materials, and devices, and from other conditions hazardous to life and property, except that the IFC is revised by deleting all the references to "ICC Electrical Code " or "NFPA 70" and replacing those references with "Electrical Code as adopted by 8 AAC 70.025, as amended as of April 16, 2022" and the IFC is revised by deleting all references to the "International Plumbing Code" and replacing them with "Plumbing Code as adopted by 8 AAC 63.010, as amended as of April 24, 2020" and the IFC is revised by deleting all the references to "International Fuel Gas Code", with the exception of Chapter 3 Section 304 and Chapters 6 and 7. Additionally, the IFC is changed with the following revisions: (1) Chapter 1, (Administration) of the IFC, Section 101.1 (Scope and general requirements) is revised to change: [NAME OF JURISDICTION] to City of Seward. (2) Chapter 1, (Administration) of the IFC, Section 103.1, Creation of Agency is revised to read: "The Seward Fire Chief and Building Inspector shall be known as the fire code official responsible for the implementation, administration and enforcement of the provisions of this code. (3) Chapter 1 of the IFC, Section 104.7 is deleted. (4) Chapter 1, (Administration) of the IFC, Section 105 (Permits) is revised by adding a new sentence to 105.4.1 to read: "In addition to two sets of printed construction documents, one electronic copy shall be submitted". (5) Chapter 1, (Administration) of the IFC, Section 105 (Permits) is revised by adding a new section 105.4.2.2 to read: "105.4.2.2 Fire system plans shall be designed by a State of Alaska Fire System Permit Holder Level IC, IIC or IIIC in accordance with AS 18.70.090 and 13 AAC 50.027 or a professional fire protection engineer, mechanical engineer or electrical engineer registered under AS 08.48. Plans shall include the following on each drawing: 1. Original signature and date on professional seal, or digital signature and date on professional seal. 2. State of Alaska Fire System Permit license number with permit level designation or Engineer license number; and date. (6) Chapter 1, (Administration) of the IFC, Section 105.5 (Required operational permits) is revised by deleting all operational permits except for: 105.5.16 Explosives, 105.5.17 Fire Hydrants and valves, 105.5.32 Mobile food preparation vehicles, 105.5.34 Open Burning, 105.5.36 Open flames and candles, 105.5.40 Plant extraction systems, 105.5.41 Private fire hydrants 105.5.42 Pyrotechnic special effects material, 105.5.49 Temporary membrane structures and tents. And adding to the last sentence to read: Any fees associated with an operational permit are set by Resolution by the City of Seward Council. (7) Chapter 1, (Administration) of the IFC, Section 105.6 (Required construction permits) is revised by deleting all construction permits except for: 105.6.1 Automatic fire extinguisher systems, 105.6.6 Fire alarm and detection systems and related equipment, 105.6.7 Fire pumps and related equipment, 105.6.11 Gates and barricades across fire apparatus access roads, 105.6.17 Plant extraction systems, 105.6.18 Private fire hydrants, 105.6.19 Smoke control or smoke exhaust systems, 105.6.21 Special event structure, 105.6.23 Standpipe systems, 105.6.24 Temporary membrane structures, tents and canopies. (8) Chapter 1, (Administration) of the IFC, Section 105.6.24 (Temporary membrane structures, tents and canopies) is revised by adding the following phrase after "in excess of 400 square feet (37 m⁁2).": "There is a mandatory ninety day period between the date an operational permit expires and the date a substantially similar operational permit (under section 105.5.49 of the IFC) or construction permit (under this section) can be issued. Temporary membrane structures, tents and canopies must be taken down during this period. Whether a permit is substantially similar is determined by the fire code official based on factors such as location, size and use. (9) Chapter 1, (Administration) of the IFC, Section 107 (Fees) is revised by adding a sentence at the end to read: "Plan review fees for construction, alteration, repair, or changing the occupancy of a building, a substantial land structure, or structure regulated by the authority having jurisdiction, to include that of Fire system plan review, will be included in the Building Permit fee covered in the International Building Code Section 109 and SCC. If work is being done contrary to the provisions of this section, the City may order the work stopped by notice in writing served on any persons engaged in or causing the work to be done. The persons doing the work shall immediately stop the work until authorized by the Fire Chief or building official to proceed." (10) Chapter 1, (Administration) of the IFC, Section 111 (Means of Appeals) is amended to delete the entire section and replace it with "Appeals of orders, decisions or determinations made by the Fire Chief or building official relative to the application and interpretation of this code shall be in accordance with Seward City Code Section 9.15.112". (11) Chapter 1, (Administration) of the IFC, Section 112.4 (Violation penalties) is revised by deleting: "shall be guilty of a [specify offense], punishable by a fine of not more than [amount] dollars or by imprisonment not exceeding [number of days], or both such fine and imprisonment"; and replace with: "shall be in violation of SCC 9.15 and AS 18.70.100 is guilty of a Class B misdemeanor and punishment shall be as set forth in AS 12.55." (12) Chapter 1, (Administration) of the IFC, Section 113.4 (Failure to comply) is revised by deleting "subject to fines established by the authority having jurisdiction" and replace with "shall be in violation of SCC 9.15 and AS 18.70.100 is guilty of a Class B misdemeanor and punishment shall be as set forth in AS 12.55." (13) Chapter 2, (Definitions) of the IFC, Section 202 (General definitions) the definition of "airport" is revised by deleting "with an overall length greater than 39 feet (11,887 mm) and an overall exterior fuselage width greater than 6.6 feet (2,012 mm)". (14) Chapter 2, (Definitions) of the IFC, Section 202 (General definitions) the definition for "occupancy classification", the introductory language of the sub-definition of "Educational Group E: Group E, day care facilities" is revised by adding a sentence at the end to read: "Family child care homes occupied as their primary residence (Group R-3) operating between the hours of 6:00 a.m. and 10:00 p.m. may accommodate a total of 12 children of any age without conforming to the requirements of a Group E occupancy except for (1) smoke alarms as described in Section 907.2.11.2; (2) carbon monoxide detectors and alarms as specified in Section 908 adhering to AS 18.70.095; (3) means of egress requirements of Section 1003, including emergency escape and rescue openings, as required by Section 1029, in napping or sleeping rooms; and (4) fire extinguisher requirements as described in the IFC." (15) Chapter 2, (Definitions) of the IFC, Section 202 (General definitions) Occupancy Class, [BG] Residential Group R-3, Lodging houses (transient) with five or fewer guestrooms and 10 or fewer occupants, is revised to add at the end of the sentence: "with no provisions for cooking or warming food in the guest rooms." (16) Chapter 3, (General requirements) of the IFC, Section 307.2 (Permit required) is revised to read: "Approval. The fire chief may allow a fire for recognized silvicultural or range or wildlife management practices, prevention, or control of disease or pests, or a bonfire. An application, as required by the fire chief, must be presented by the owner of the land upon which the fire is to be kindled before kindling that fire." (17) Chapter 3, (General requirements) of the IFC, Section 308.1.1 (Where prohibited) is revised by adding a new sentence at the end to read: "No person shall release or cause to be released any unmanned free-floating devices on land, in the air, or on water; containing an open flame or other heat source, including sky lanterns." (18) Chapter 3, (General requirements) of the IFC, Section 308.3 (Group A occupancies) is revised to read: "308.3 Group A occupancies. The use of open flame in connection with a public meeting or gathering for the purposes of deliberation, worship, entertainment, amusement, instruction, education, recreation, awaiting transportation, or similar purposes in assembly or educational occupancies must be done in consultation with the fire department." (19) Chapter 3, (General requirements) of the IFC, Section 311 (Vacant Premises) is revised by deleting Section 311.5 (Placards); (20) Chapter 4, (Emergency planning and preparedness) of the IFC, Section 401 (General) is revised by adding a new section to read: "401.3.4 False alarm charges. The owner of a building containing a fire alarm or fire protection systems shall pay a charge in accordance with SCC 9.15.150 for false alarms to which the fire department responds. As used in this Section, "false alarm" means an alarm signal generated by a fire alarm system reporting an alarm for which no fire or emergency actually exists, and includes system malfunctions, faulty operation of detectors, and false alarms not classified above. It does not include incidents where the detector or system operated as designed, such as but not limited to, a smoke detector sounding from someone smoking under the detector or a manual pull station being pulled". (21) Chapter 4, (Emergency planning and preparedness) of the IFC, Section 403.4 (Group E occupancies) is revised by adding a new section "403.4.4 False Alarms to read: 'False alarms may not be counted as a fire drill for the purpose of this section'." (22) Chapter 4, (Emergency planning and preparedness) of the IFC, Section 403.9.2.1 (College and university buildings) is revised by adding a new section "403.9.2.1.3 False Alarms to read: 'False alarms may not be counted as a fire drill for the purpose of this section'." (23) Chapter 4, (Emergency planning and preparedness) of the IFC, Section 405.3 (Frequency) is revised by adding a second sentence at the end of the section to read: "False alarms may not be counted as a fire drill for the purpose of this section." (24) Chapter 4, (Emergency planning and preparedness) of the IFC, Section 407.1 (General) is revised to read: "407.1 General. The provisions of Sections 407.2 through 407.7 shall be applicable, in the discretion of the fire chief." (25) Chapter 5, (Fire service features) of the IFC, Section 501.3 (Construction documents) of the IFC, is revised by adding a second paragraph to read: "The fire chief may require fire apparatus access roads, premises identification, key boxes, fire protection water supplies, fire protection and utility equipment identification and access, and emergency responder radio coverage in accordance with this chapter. Documentation shall be provided indicating that the fire chief has been involved in discussion regarding fire apparatus access roads, premises identification, key boxes, fire protection water supplies, fire protection and utility equipment identification and access, and emergency responder radio coverage.". (26) Chapter 5 (Fire service features) of the IFC, Section 507 (Fire protection water supplies) of the IFC, amend Section 507.1 by adding the following exceptions: "Exception: In areas of the City not served by a water utility the following structures do not require a water supply: 1. Detached one- and two-family dwellings regulated by the International Residential Code and protected throughout by an approved automatic fire sprinkler system; 2. Structures accessory to detached one- and two-family dwellings and regulated by the International Residential Code having 3,000 square feet or less gross floor area; 3. Structures classified as a Group U occupancy in accordance with the International Building Code having 3,000 square feet or less gross floor area; 4. Structures classified as a Group U occupancy in accordance with the International Building Code in excess of 3,000 square feet of gross floor area and protected throughout by an approved automatic fire sprinkler system; 5. Buildings protected throughout by an approved automatic fire sprinkler system and constructed of Type I-A or I-B construction in accordance with the International Building Code; 6. Buildings protected throughout by an approved automatic fire sprinkler system and constructed of Type II-A construction when Type II-B construction is allowed based on occupancy classification, allowable height and allowable area in accordance with the International Building Code; 7. Buildings protected throughout by an approved automatic fire sprinkler system and constructed of Type III-A construction when Type III-B construction is allowed based on occupancy classification, allowable height and allowable area in accordance with the International Building Code; and 8. Buildings protected throughout by an approved automatic fire sprinkler system and constructed of Type V-A construction when Type V-B construction is allowed based on occupancy classification, allowable height and allowable area in accordance with the International Building Code." (27) Chapter 5, (Fire service features) of the IFC, Section 507.5.1, (Where required) is revised to read: "507.5.1 Where required. Where a portion of the facility or building hereafter constructed or moved into or within the City is more than 250 feet (76.20 meters) from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the building official or fire chief." This section is further revised by deleting Exceptions 1 and 2. (28) Chapter 5, (Fire service features) of the IFC, Section 507.5.2 (Inspection, testing and maintenance) is revised to add to the last line; "in accordance with NFPA 291." (29) Chapter 6 (Building Services and Systems) of the IFC, Section 606.3.3.2 (Grease accumulation) is revised to read: "606.3.3.2 Grease accumulation. If during the inspection it is found that hoods. grease-removal devices, fans, ducts or other appurtenances have an accumulation of grease, those components shall be cleaned in accordance with NFPA 96 or ANSI/IKECA ClO for cleaning only. (30) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 901.2 (Construction documents) is revised by adding a new sentence at the end to read: "A copy of the completed fire system construction documents shall be kept safe and secured near the riser for the life of the system and available for inspection." (31) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 901.4 (Installation) is revised by adding an exception to read: "Exception: Buildings temporarily closed due to seasonal operations may have their fire systems deactivated under the following conditions: 1. The building is unoccupied; 2. The building is properly secured; 3. All utilities are disconnected and drained; 4. The fire systems are certified as operational before the building is reoccupied; 5. A 24-hour-a-day fire watch is provided during the interim between when utilities are reactivated, and the fire systems are certified as operational; 6. The fire chief or building official is notified in writing of the closure; and 7. A letter from the insurance carrier, or the owner if self-insured, indicating knowledge of the closure is provided to the fire chief or building official." (32) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 901.5 (Installation acceptance testing) is revised to read: "901.5 Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire standpipes systems, and other fire protection systems and appurtenances to those systems must meet the approval of the authority having jurisdiction as to installation and location, and are subject to the acceptance test required by the standard in IFC Table 901.6.1 for the system or appurtenance. Within 30 days after the completion of the installation, a copy of the acceptance test certificate must be forwarded by the firm conducting the test to the deferred authority having jurisdiction. Fire hydrant systems, fire pump systems, and private fire service mains installed as a requirement by the fire chief are subject to the acceptance tests as contained in the installation standards and as approved by the fire chief. The fire chief must be notified before any required testing, and all results of the tests must be conveyed to the fire chief within 30 days." (33) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 901.6 (Inspection, testing and maintenance) is revised by adding a second paragraph to read: "Superseding other code or standard requirements established by this section, fire protection systems and fire extinguishers must be inspected, tested, and serviced as follows: 1. Annually; Exception: Standpipe systems must be inspected, tested, and serviced every five years; 2. After any use or activation; 3. Any time damage is found; 4. After repair or alteration; 5. When required by the fire chief or building official; and 6. After a seasonal shutdown. Reports of inspections and tests must be maintained on the premises, and within 30 days after the inspection or test being completed, a copy of the test report must be forwarded by the person conducting the inspection or test to the fire chief or building official. The annual fire extinguisher testing may be performed by any person who has a valid permit in accordance with 13 AAC 50.030(d)." (34) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 901.7 (Systems out of service) of the IFC, the first sentence is revised to read: "Where a required fire protection system is out of service for more than eight hours in a 24-hour period, an impairment plan shall be submitted to the fire chief immediately. Where required by the fire chief, the building shall either be evacuated, or an approved fire watch shall be provided for all occupants left unprotected by the shutdown until the fire protection system has been returned to service. A daily fire watch log will be submitted to the fire chief for each 24-hour period." (35) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 903.2.3 (Group E) is revised to read: "903.2.3 Group E. An automatic sprinkler system must be provided throughout all buildings with Group E occupancies. The use of a fire wall or barrier does not establish a separate building or fire area for purposes of this section. As determined by the fire chief or building official an automatic fire-extinguishing system approved under Section 904 shall be installed in a Group E occupancy in accordance with Section 903.2.3, whenever alterations or additions are made to an existing structure containing a Group E occupancy Exception: Buildings with Group E occupancies having an occupant load of 50 or less. An automatic sprinkler system must also be provided for every portion of educational buildings below the level of exit discharge. Family childcare homes that are licensed to care for more than five persons between the hours of 10:00 p.m. and 6:00 a.m. must be equipped with an automatic sprinkler system designed and installed as described in Section 903.3.1.3 or an equivalent system approved by the fire chief or building official." (36) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 903.2.8 through 903.2.8.3 is revised to read: "903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout buildings containing Group R occupancies as provided in this section. 903.2.8.1 Group R-1. An automatic sprinkler system shall be provided throughout all buildings that contain an R-1 occupancy. 903.2.8.2 Group R-2. An automatic sprinkler system shall be provided throughout all buildings that contain an R-2 occupancy. Exceptions: 1. Buildings that are no more than two stories in height, including basements and contain four or fewer dwelling units. 2. Buildings that are no more than two stories in height, including basements and contain 16 or fewer sleeping rooms. For the purpose of this section, fire walls may be used to create up to three separate attached buildings. Any additional buildings must be physically separated in accordance with International Building Code (IBC) Table 602, as adopted by reference in 13 AAC 50.020. 903.2.8.3 Group R-4. A 13R automatic sprinkler system shall be provided throughout all buildings that contain an R-4 occupancy." (37) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 903.3.6 (Hose threads) is revised by deleting "the fire code official" and replacing it with "AS 18.70.084" (38) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 903.5 (Testing and maintenance) is revised by adding a new Section 903.5.1 to read: "903.5.1 Camp relocations. On each portable or relocatable camp move, a plumber certified under AS 18.62 may disconnect and reconnect the fire suppression system. The camp must be certified by an appropriate fire suppression permit holder under AS 18.70.090 and 13 AAC 50.035 to provide documentation that the system has been placed back in service and is ready for operation. Fire suppression system certification documentation is to be retained on site and available for review upon request. Annual requirements are still required by this code as adopted by reference in 13 AAC 50.025." (39) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 903 (Automatic Sprinkler Systems) is revised by adding a new Section 903.3.9 to read: "903.3.9 Seismic Design. Fire sprinkler systems shall have a minimum simplified seismic factor seismic design coefficient Cp of 0.72 or greater as by NFPA 13." (40) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 903.4 (Sprinkler system supervision and alarms) is revised by amending exception number 1 by adding the following to the end of the sentence: "not used as an assisted living or custodial care facility." (41) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 904.1 (General) is revised by adding a new sentence at the end of the paragraph to read: "Within 30 days after the completion of the installation, a copy of the acceptance test certificate must be forwarded by the firm conducting the test to the authority having jurisdiction. (42) Chapter 9, (Fire Protection and life safety systems) of the IFC, Section 904.13.5.2 (Extinguishing system service) is revised by replacing "not less frequently than every six months" with "annually". (43) Chapter 9, (Fire Protection and life safety systems) of the IFC, Section 906.1 (Where required) is revised by deleting the exception in item 1. (44) Chapter 9, (Fire Protection and life safety systems) of the IFC, Section 907.2.3 (Group E) Exception 1 is revised by replacing "50" with "49". (45) Chapter 9, (Fire Protection and life safety systems<yrrule> of the IFC, Section 907.2.11.2 (Groups E, R-2, R-3, R-4, and I-1} is revised by adding a reference in the section heading to Group E, as indicated, and adding a second paragraph to read: "Rooms used for sleeping or napping purposes within a daycare use of a Group E occupancy must be provided with smoke alarms that comply with this section. (46) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 907.2.11.5 (Interconnection) is revised by adding a new paragraph to read: "If more than 12 smoke alarms are interconnected the interconnecting means must be supervised in accordance with NFPA 72." (47) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 907.7.2 (Record of completion) is revised by adding a second paragraph to read: "Within 30 days after the completion of the installation, a copy of the acceptance test certificate verifying completion in accordance with NFPA 72 must be forwarded by the firm conducting the test to the authority having jurisdiction." (48) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 907.8 (Inspection, testing and maintenance) is revised by adding a new Section 907.8.6 to read: "907.8.6 Camp relocations. On each portable or relocatable camp move, an electrician certified under AS 18.62 may disconnect and reconnect the fire alarm system. The camp must be certified by an appropriate fire system permit holder under AS 18.70.090 and 13 AAC 50.035 to provide documentation that the system has been placed back in service and is ready for operation. System certification documentation is to be retained on site and available for review upon request. Annual requirements are still required under this code as adopted by reference in 13 AAC 50.025." (49) Chapter 9, (Fire protection and life safety systems) of the IFC, Section 909.18 (Acceptance testing) is revised by adding a new sentence at the end of the paragraph to read: "Within 30 days after the completion of the installation, a copy of the smoke control system acceptance testing certificate must be forwarded by the firm conducting the test to the authority having jurisdiction.". (50) Chapter 10, (Means of egress) of the IFC, Section 1001.1 (General) last sentence of the paragraph is revised by adding at the end "as governed by the provisions of AS 18.70.080" (51) Chapter 10, (Means of egress) of the IFC, Section 1009.2 (Continuity and components) is revised by adding a new Section 1009.2.2, Minimizing Snow and Ice Accumulation, to read: In all occupancies, surfaces and landings which are part of the exterior egress to include stairs, ramps, or balconies shall be designed to minimize the accumulation of snow or ice." (52) Chapter 10, (Means of egress) of the IFC, Table 1020.2 (Corridor fire-resistance rating) is revised by inserting a superscript "e" footnote reference after "R" in the "occupancy" column and is revised by adding footnote "e" to read: "R occupancies with an occupant load greater than 10 shall have one-hour rated corridors when the R occupancies are allowed to not have a sprinkler system and 1. serve four or fewer dwelling units or 16 or fewer sleeping rooms; and 2. are less than three stories in height."; (53) Chapter 10, Section 1031.2 (Where required) of the IFC, is revised by replacing the first sentence to read: "In addition to the means of egress required by this chapter provisions shall be made for emergency escape and rescue openings in Group R and I-1 occupancies." (54) Chapter 10, (Means of egress) of the IFC, Section 1031.2 (Where required) is revised by deleting Exceptions 1 & 3. (55) Chapter 11, (Construction requirements for existing building) of the IFC, Section 1103 (Fire safety requirements for existing building) is revised to add Section 11.03.11 to read: "11.03.11 Monitoring. Monitoring shall be provided for all existing occupancies with fire sprinkler or fire alarm systems. Fire sprinkler system monitoring shall comply with Sections 903.4 and 903.4.1. Fire alarm monitoring shall comply with Section 907.6.6." (56) Chapter 20, (Aviation Facilities) of the IFC, Section 2006.3 (Construction of aircraft-fueling vehicles and accessories) of the IFC, is revised by adding an exception to read: "Exception: A vehicle or trailer tank with a capacity of 250 gallons or less may be used for non-commercial refueling of private non-commercial aircraft if the following requirements are met: 1. The tank is placarded with no smoking signs, the type of fuel contained in the tank, and the tank capacity; 2. The tank and all appurtenances used in the fueling operation are listed and approved for the specific purpose; and 3. Electrical bonding is provided as required under Section 2006.3.7." (57) Chapter 23, (Motor fuel-dispensing facilities and repair garages) of the IFC, Section 2311.2.3 (Drainage and disposal of liquids and oil-soaked waste) is revised by adding a sentence at the end of the paragraph to read: "Where oil separators or traps are provided, neither the oil nor water phase may drain to septic systems, dry wells, or other means of underground discharge." (58) Chapter 50, (Hazardous materials-general provisions) of the IFC, Section 5001.6 (Facility closure) is revised by adding new sentences at the end of the paragraph to read: "The fire chief may require the documentation of the closure plans for the termination of the storage, use, or handling of hazardous materials at least 30 days before the termination. The fire chief is authorized to require that the documentation include an approved facility closure plan in accordance with Section 5001.6.3. The fire chief may require the submission of the Hazardous Materials Management Plan and Hazardous Materials Inventory Statement indicated in Sections 5001.5.1 and 5001.5.2." (59) Chapter 56, (Explosives) of the IFC, Section 5601.1 (Scope) is revised to insert "and AS 18.72" after "The provisions of this chapter". (60) Chapter 56, (Explosives) of the IFC, Section 5601.1.1, (Explosive material standard) is revised to read: "In addition to the requirements of this chapter, Seward City Code Chapter 9.15, Article 3 and NFPA 495 shall govern the manufacture, transportation, storage, sale, handling and use of explosive materials." (61) Chapter 56, (Explosives) of the IFC, Section 5608 (Fireworks Display) 5608.2 (Permit application) is revised to add: "Fireworks Display Permit application must be submitted to the City of Seward to include a site and safety plan, production schedule, copy of the operator's State of Alaska Permit, and certificate of insurance prior to approval by the fire code official." (62) Chapter 56, (Explosives) of the IFC, Section 5608.6 (Installation of mortars) is revised by adding a new Section 5608.6.1 to read: "5608.6.1 Mortar construction. Mortars must be constructed of paper, high density plastic pipe, or metal other than cast iron." (63) Chapter 57, (Flammable and noncombustible liquids) of the IFC, Section 5704.3.5 (Storage in control areas) is revised by deleting Section 5704.3.5.1 (Basement storage). (64) Chapter 57, (Flammable and noncombustible liquids) of the IFC, Section 5706.3 (Well drilling and operating) is revised by adding a second sentence to read: "This section does not apply to offshore oil platforms." (65) Chapter 58, (Flammable gases and flammable cryogenic fluids) of the IFC, Section 5801 (General) is revised by adding a new Section 5801.3 to read: "5801.3 Plan review. Where a single container is over 500-gallon (1,892.7 L) water capacity or the aggregate capacity of containers is over 500-gallon (1,892.7 L) water capacity, the installer shall submit plans for review before installation in accordance with 13 AAC 50.027." (66) Chapter 80 (Referenced Standards) of the IFC, is revised to amend the Reference Standards as follows: "Add NFPA 291-19 Recommended Practice for Fire Flow Testing…Ref. 507.5.2." (67) Appendix B, (Fire-Flow requirements for buildings) of the IFC, Section B105.1 (One-and two-family dwellings Group R-3 and R-4 buildings and townhouses) is revised by adding the following exception: "Exception: Buildings protected throughout with an approved automatic fire sprinkler system" (68) Appendices, the appendices of the IFC are amended by adding Appendix KK to read: "APPENDIX KK FIRE STATUS REPORTING KK101 Scope. All fire alarm and protection service companies providing services in the City of Seward shall provide a legible copy of all fire system service reports to the City as adopted and amended in the IFC 2021 Edition as listed in this appendix. Exception: Industrial occupancies with a fire system preventive maintenance program approved by the division of fire and life safety. This appendix contains contact information. KK102 Status 1. Systems out of service or major deficiencies. The fire service company shall immediately contact the Fire Chief if the system cannot be returned to service. On a weekend or after hours, contact, Seward Dispatch at: 907-224-3338 and request the on-call fire officer be contacted. Written notification shall be sent by facsimile transmission or email to the Fire Chief within 24 hours from the time the system first could not be returned to service. KK102.1 Corrective action time. Status 1 systems shall be repaired immediately, and a Fire Watch implemented prior to any occupation of the building. KK102.1.1 For example but not limited to KK102.1.1.1 Fire sprinkler or water-based systems: 1. Non-working flow/pressure switches. 2. Damage to fire department connections. 3. No water to system. 4. Frozen or otherwise damaged system. KK102.1.1.2 Fire pumps: 1. Non-working fire pumps. 2. Fire pump controls not working or malfunctioning. KK102.1.1.3 Fire alarm systems (detection and alarm): 1. Non-working fire alarm panel. 2. Malfunctioning fire alarm panel. 3. Audio and visual devices not working entire loop. 4. Detection not working entire detection loop. 5. Loss of programming. KK102.1.1.4 Kitchen hood fire systems: 1. System cylinder is not charged or leaking. 2. Appliance not properly covered due to rearrangement of appliances. 3. Plugged discharge nozzles. 4. Automatic detection not functional. 5. Gas or electric not shutting down. KK102.1.1.5 Clean agent or special hazard system: 1. System cylinder is not charged or leaking. 2. Releasing panel not functional. KK103 Status 2. Critical deficiencies. If systems have critical deficiency reports, the critical deficiency reports shall be provided to the Fire Chief within 14 days from the date of initial receipt of the critical deficiency report. KK103.1 Corrective action time. Status 2 systems shall be repaired within 14 days. KK103.1.1 For example but not limited to KK103.1.1.1 Fire sprinkler or water-based system: 1. Five or more painted sprinkler heads in a concentrated area or more than 10 in a facility. 2. Change of use that will affect the performance of the sprinkler system. 3. Low water pressure. 4. No monitoring on required systems. 5. Any other major problem that will affect the performance. KK103.1.1.2 Fire pumps: 1. Low fuel 2. Pump packing leaking beyond specifications. 3. Fire pump room below 40 degrees. 4. Fire pump not meeting its rated discharge pressure or GPM flow over a 10 percent difference. 5. Any other major problem that will affect the performance. KK103.1.1.3 Fire alarm systems (detection and alarm): 1. Batteries overdue for replacement. 2. No monitoring on required system. 3. Audio and visual devices not working - up to three devices, over three devices Status 1. 4. Detection not working - up to three devices, over three devices Status 1. 5. Any other major problem that will affect the performance. KK103.1.1.4 Kitchen hood fire systems: 1. Hood and ducts with heavy grease buildup. 2. Any other major problems that will affect the performance. KK104 Status 3. Minor deficiencies. Minor deficiency reports shall be provided to the authority having jurisdiction or closest state division of fire and life safety office within 30 days. These deficiencies will not affect the performance of the system. KK104.1 Corrective action time. Status 3 systems shall be repaired within 30 days. KK105 Status 4. No deficiencies. Systems with no deficiencies shall be reported to the authority having jurisdiction or closest state division of fire and life safety office within 30 days. KK106 Information to be provided. System service reports shall have the following information as follows: 1. The inspection company name shall be printed on all reports with the company's address and telephone number. 2. The inspector's first and last name shall be printed with the permit number of the inspector's fire systems permit required under AS 18.70.090 and 13 AAC 50.035. 3. The inspector's office telephone number shall be printed, and the inspector's cellular telephone number, if available, shall also be printed. 4. Deficiencies shall be typed or written and shall be printed text. No cursive or longhand handwriting is acceptable. Typed reports shall use at least 10-point font and handwritten reports shall use at least 3/8 inch spacing between lines. 5. All reports shall have the building name, occupancy inspected, and address clearly identified on the first page, and all subsequent pages shall have the building name and date of inspection on the top of the page. 6. All reports shall have the building contact person's name with telephone number on the front page. 7. Only white and yellow copies will be accepted by the City of Seward for reports submitted. 8. Deficiency write ups must include the code provision being violated and a description of the problem. 9. All reports must include the Status Number on the first page of the report. 10. All Corrective Actions Reports shall be sent within 30 days of work completion. All system service reports shall be sent to: Seward Fire Department Po Box 167, Seward, AK 99664; Phone 907-224-3445, Fax 907-224-8633, Email: [email protected] Systems out of service and those with major deficiencies shall have a report faxed or emailed to the Seward Fire Department and mailed immediately within one day to the address listed in this appendix.

(Ord. No. 2023-010, § 1, 5-8-2023)

Ask a question about Seward law

Corpus searches the Seward sections it holds and shows the ones that match, with their citations. Free, no sign-in.