§ 12-12.5-16 — Compliance with article
Code of Ordinances of the City of Birmingham, Alabama (Supp. No. 3: codified through Ordinance No. 20-107, enacted June 29, 2020) · Birmingham Code of Ordinances § 12-12.5-16
Corpus is an independent public-information project, not the official City of Birmingham website. Stable reference: corpuslaw.us/code/81065122-4bf1-426b-848e-365a5ad612b9
Sec. 12-12.5-16. - Compliance with article.
It shall be unlawful for any person to operate a mobile home park or occupy any unit in any such park within the city, except in compliance with this article. (1) A permit shall be obtained from the Jefferson County Health Department. (2) Roads within a mobile home park shall be not less than 24 feet wide and shall be well drained. Such roads shall be clearly marked and adequately lighted at night, and easily accessible to all units. Unit sites shall be indicated with corner markers, and each unit site shall be identified by a clearly visible number. (3) Every unit site shall be furnished with a water service and backflow protected outlet capable of supplying all units with potable water at not less than 14 gallons per minute and not less than eight pounds per square inch pressure at the highest water outlet in each unit supplied when the park water system is under maximum demand. (4) Every unit site shall be furnished with a properly connected house trap (four-inch running trap) with a cleanout on the inlet side and vented on the outlet side as provided in the plumbing code for fixture traps. Such trap shall be properly connected to an approved site sanitary sewer which is constructed in accordance with applicable provisions of the plumbing code of the city [see section 7-1-5]. Every independent unit shall be connected to the house trap with materials which meet requirements of the plumbing code for drainage waste and vents. (5) All waste or sewage from showers, water closets, laundries, lavatories or other plumbing fixtures shall be wasted into a sewer connected with the city sanitary sewer system as required for building sewers in the plumbing code of the city. (6) All sanitary facilities in any unit which are not connected with the city sewer system by means of rigid pipe connections shall be sealed, and their use is hereby declared unlawful. (7) No wastewater shall be thrown or discharged upon the surface of the ground or disposed of by means other than as herein provided. (8) All units connected to the park drainage or water supply system shall be in accordance with the applicable ordinances of the city, and all units connected to the park drainage (sewage) or water supply system shall bear certification of compliance with A.N.S.I. Standard A119.1/NFPA 501D. (9) No unit shall be connected to any sewer or water supply system other than in accordance with the requirements of this article or other applicable ordinances of the city. (10) Every park accommodating dependent units shall have erected thereon at a distance not greater than 200 feet from any dependent unit a suitable building for housing toilet facilities required by this article. Such building shall be known as the "service building." (11) Each service building shall be equipped with and provide the following: a. Separate toilet rooms for each sex with elongated water closets provided with an adequate water supply in separate compartments having a minimum width of two feet, six inches, and shall be provided for each sex in the ratio of one water closet for each sex per each eight units or fraction thereof. Every male toilet room shall have on urinal for each two or less required water closets, but in no case shall any male toilet be without one urinal. Toilet rooms shall contain lavatories with hot and cold water in the ratio of one lavatory to every two or less water closets. b. Separate bathing facilities for each sex shall be provided with one shower enclosed in a compartment having a floor area of not less than nine square feet and with the least dimension being not less than 36 inches, for each eight units or fraction thereof. Each shower compartment shall be supplemented by an individual dressing compartment of at least 12 square feet. c. Laundry facilities shall be provided in the ratio of one properly connected double laundry tub or one clothes washing machine and one clothes dryer for each ten units. d. The above accommodations shall be based on the total camp capacity according to accepted plans. e. Floors of toilet rooms, shower rooms and the laundry room shall be of concrete, tile or similar material impervious to water and easily cleaned and pitched to a floor drain. f. For use of registered guests, each service building shall have not less than one backflow protected wall-mounted hydrant on each side of the building which faces an access drive or paved walkway.
(Code 1980, § 12-12.5-16; Ord. No. 81-210, art. I, § I, 12-8-1981)
Ask a question about Birmingham law
Corpus searches the Birmingham sections it holds and shows the ones that match, with their citations. Free, no sign-in.
