Sec. 4-5-158. - Height of wires.

(a) All wires above any street, avenue or alley must be maintained at a minimum height of 18 feet above the ground, and in crossing any such street, avenue or alley, must be run horizontally if practicable. (b) If a communication service drop or a guy which is effectively insulated against the highest voltage to which it is exposed crosses a street or alley, the clearance may be reduced to 16 feet at the side of the public way; provided that this provision for reduction of clearance shall not apply to any drop or guy exposed to a voltage in excess of 8,700 volts. (c) Where communication wires or cables cross over or run along alleys, this clearance may be reduced to 15 feet.

(Code 1964, § 48-84; Code 1980, § 4-5-158)