§ 7-56 — Adopted; amendments
City Code of the City of Decatur, Alabama (Codified through Ordinance No. 24-4600, adopted December 16, 2024. (Supp. No. 37)) · Decatur City Code § 7-56
Corpus is an independent public-information project, not the official City of Decatur website. Stable reference: corpuslaw.us/code/17f1bf38-0736-475f-8ea6-1e56fbbd5837
Sec. 7-56. - Adopted; amendments.
Pursuant to the authority granted cities and towns by section 11-45-8 Code of Alabama, 1975, there is hereby adopted that certain code printed in book or pamphlet form known as follows: "International Residential Code for One and Two Family Dwellings TM " 2009 Edition, promulgated and published by the International Code Council together with the reference codes and standards, and appendices and indices forming a part thereof, save and except the following portions thereof as shall be deleted, modified, amended or extended as follows: (1) Any reference in the code to the "building official" shall read to mean the building director or any other head of the building department. (2) Any reference in the code to the "department of building safety" shall read to mean the building department as enumerated in article IV of chapter 2, section 2-76 of the Code of Decatur, Alabama. (3) Section R112 Board of Appeals is hereby amended to read as follows: "Section R112 Board of Appeals. The board of examinations and appeals for the construction industries, established under Article II of chapter 7 of the Code of Decatur, Alabama, shall serve as the board of adjustments and appeals under this code, and all references to the board of adjustments and appeals shall refer to the board of examinations and appeals for the construction industries which board shall have the power and authority therein granted the board of adjustments and appeals." (4) And all requirements as adopted by the State of Alabama relating to the 2009 Edition of the Alabama Energy and Residential Codes except as outlined below: A) Appendix F - Radon Control Methods; Appendix G- Swimming Pools, Spas, and Hot Tubs; Appendix H-Patio Covers; and Appendix O- Gray Water Recycling Systems are all hereby adopted as part of the Code. B) Appendix A - Sizing and Capacities of Gas Piping; Appendix B-Sizing of Venting Systems serving Appliances equipped with Draft Hood, Category 1 Appliances, and Appliances listed for use with Type B Vent; and Appendix C - Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems are all adopted as informative and as guidelines in the interpretation of the Code, and not adopted as part of the Code. C) Appendix D - Recommended Procedure for Safety Inspection of an Existing Appliance Installation; Appendix E- Manufactured Housing used as Dwellings; Appendix I- Private Sewage Disposal; Appendix J- Existing Buildings and Structures; Appendix K- Sound Transmission; Appendix L- Permit Fees; Appendix M- Home Day Care- R-3 Occupancy; and Appendix P- Sizing of Water Piping System are all not adopted as part of the Code and deleted in their entirety. D) Under IRC Chapter 6 Wall Construction make the following changes: (a) R602.10 Wall bracing. Replace entire section with section R602.10 Wall bracing from the 2012 version of the International Residential Code. (b) R602.11 Wall anchorage. Replace entire section with section R602.11 Wall anchorage from the 2012 version of the International Residential Code. (c) R602.12 Wall bracing and stone masonry veneer. Replace entire section with section 602.12 Simplified wall bracing from the 2012 version of the International Residential Code. (5) Table 301.2(1) is hereby amended to read as follows: Ground Snow Load | Wind Design | Seismic Design Category f | Subject to Damage From | Winter Design Temp. e | Ice Barrier Under- layment Required h | Flood Hazards g | Air Freezing Index l | Mean Annual Temp. i Speed d (mph) | Topographic Effects | Weather- ing a | Frost Line Depth b | Termite c 10 lb./ft 2 | 90 | No | B | Moderate | 12" | Very Heavy | 16° | No | 9/5/1979 12/15/2005 | 200 | 59° (6) Section R315.2 Carbon Monoxide Alarms; Where required in existing buildings is hereby amended to read as follows: "R315.2 Where required in existing dwellings. The individual dwelling unit shall be equipped with carbon monoxide alarms located as required for new dwellings when any one of the following is present: 1. When alterations, repairs or additions requiring multiple permits occur. 2. When adding or creating a bedroom in an existing dwelling that has attached garages or in which fuel-fired appliances exist. 3. Adding or creating an attached garage. 4. Installing a fuel burning appliance. 5. Re-establishment of gas service. Work involving only the exterior surfaces of dwellings, such as the replacement of roofing or siding, the addition or replacement of windows or doors, the addition of a porch or deck, are exempt from the requirements of this section." (7) Section E3902.11 Arc-Fault Circuit-Interrupter Protection is hereby amended to read as follows: "E3902.11 Arc-fault circuit-interrupter protection. All branch circuits that supply 120-volt, single phase, 15- and 20-ampere outlets installed in bedrooms shall be protected by a combination type arc-fault circuit interrupter installed to provide protection of the branch circuit. Exception: 1. Where a combination AFCI is installed at the first outlet to provide protection for the remaining portion of the branch circuit, the portion of the branch circuit between the branch-circuit over-current device and such outlet shall be wired with metal outlet and junction boxes and RMC, IMC, EMT or steel armored cable, Type AC meeting the requirements of Section E3908.8. 2. AFCI protection is not required for a branch circuit supplying only a fire alarm system.
Code 1956, § 9-1; Ord. No. 2153, § 2, 9-18-78; Ord. No. 2240, § 1, 8-4-80; Ord. No. 83-2326, § 2, 2-21-83; Ord. No. 83-2347, § 1, 7-11-83; Ord. No. 89-2831, § 10, 4-17-89; Ord. No. 89-2878, § 1, 11-20-89; Ord. No. 91-3017, § 1, 12-2-91; Ord. No. 95-3259, § 1, 5-1-95; Ord. No. 98-3424, § 1, 2-2-98; Ord. No. 02-3700, § 1, 9-9-02; Ord. No. 03-3779, § 1, 12-15-03; Ord. No. 12-4121, § 1, 9-4-12; Ord. No. 13-4157, § 1, 8-19-13)
Ask a question about Decatur law
Corpus searches the Decatur sections it holds and shows the ones that match, with their citations. Free, no sign-in.
