Sec. 102-375. - Grease control equipment sizing.

(a) Minimum acceptable size of grease control equipment for each FSE classification (see food service establishment section 102-368 for class details) will be as follows: (1) Class 1: 20-gpm/40 pound grease trap (hydro-mechanical grease interceptor or HGI) (2) Class 2: 1,000-gallon gravity grease interceptor (GGI) (3) Class 3: 1,500-gallon gravity grease interceptor (GGI) (4) Class 4: 2,000-gallon gravity grease interceptor (GGI) (5) Class 5: 2,000-gallon gravity grease interceptor (GGI) (b) To calculate the appropriate size GCE, the FSEs engineer, architect, licensed plumber, or contractor should use a formula that considers all kitchen plumbing fixture units, the discharge plumbing pipe diameter for each fixture unit, storage capacity, type of facility, and an adequate retention time. The grease control equipment minimum acceptable size for the above listed FSE classifications (Class 1 through 5) shall be met. (c) The city will review information received from the completed "food service establishment fats, oils, and grease inquiry form." The city will make a decision to approve, or require additional grease interceptor volume, based on the type of FSE, the number of fixture units, additional calculations and considerations. Each gravity grease interceptor tank capacity shall not exceed 2,000 gallons. In the event that the gravity grease interceptor calculated capacity needs to exceed 2,000 gallons, the FSE shall install any additional interceptor(s) of the appropriate size in series. (d) Gravity grease interceptors that are installed in series shall be installed in such a manner to ensure positive flow between the tanks at all times. Therefore, tanks shall be installed so that the inlet invert of each successive tank shall be a minimum of two inches below the outlet invert of the preceding tank or a one percent downstream slope, whichever is greater. (e) Grease control equipment must remove fats, oils, and grease at or below the City of Dothan surcharge concentration level of 150 mg/L established in chapter 102, article IV, section 102-233. Failure to comply will require enforcement action.

(Ord. No. 2015-366, § 1, 12-15-15)

Ask a question about Dothan law

Corpus searches the Dothan sections it holds and shows the ones that match, with their citations. Free, no sign-in.