§ 90-102 — Final plat specifications and requirements
Code of Ordinances of the City of Dothan, Alabama (Codified through Ordinance No. 2026-96, enacted April 21, 2026. (Supp. No. 67)) · Dothan Code of Ordinances § 90-102
Corpus is an independent public-information project, not the official City of Dothan website. Stable reference: corpuslaw.us/code/1acc332c-2220-4f84-94b3-41adbf00cf71
Sec. 90-102. - Final plat specifications and requirements.
(a) Digital format. The final plat shall also be submitted to the city in digital form utilizing the standard city layer name structure in AutoCAD or .DXF format on electronic media. (b) Conformance with the preliminary plat. The final plat shall conform to the conditions of the approved preliminary plat. (c) Original tracing specifications. The final plat shall be clearly and legibly drawn on any acceptable synthetic tracing material. The scale shall be a minimum of 100 feet to an inch on a sheet size of 24 inches by 36 inches. If the complete plat cannot be shown on one sheet of this size, it may be shown on more than one sheet with an index map at a reduced scale. (d) Bond required. A maintenance surety is required before the final plat will be signed. This surety is required for 25 percent of the total cost of all improvements in the development. The design engineer shall provide a cost schedule for these items. A two-year maintenance warranty on these items is also required. The developer must provide a letter agreeing to maintain these items for two years from the day the final plat is signed or when all punch list items are corrected and the city has inspected and accepted the work, whichever is later. (e) Design engineer's certification required. A design engineer's certification of completion must be submitted and the final inspection completed or a cash performance and two year maintenance bond must be provided before the final plat will be signed. (f) As-built engineering drawings required. Certified as-built engineering drawings for both residential and commercial developments (water, sanitary sewer and electrical for private commercial subdivisions) must be submitted. As-built plans shall be submitted in AutoCAD or .DXF format on electronic media. Once compaction test reports, water/sewer test reports, and paving density test reports have been received, the City of Dothan Public Works Department requires the submission of the following for update of the GIS system prior to having the final plat or replat signed: (1) Provide one digital drawing titled "(name of project) as constructed" in state plane coordinates with: a. A circle with the sanitary sewer lateral length and depth, plus a distance to the downstream sanitary sewer manhole for all sanitary sewer laterals. All of this information should be on one layer named "ss_lats". b. Symbols in the drawing for all sanitary sewer structures. All structures will have a description, northing and easting coordinates, elevation of top, depth and direction of inverts, line sizes and type of material used for the lines. All of the structures and text shall be on layers named "ss_structures" and "ss_text", respectively. c. Symbols in the drawing for all storm drainage structures. All structures will have a detailed (i.e.: Type II inlet, slope paved headwall, etc.) description, northing and easting coordinates, elevation of top, depth and direction of inverts, line sizes and type of material used for the lines. All of the structures and text shall be on layers named "d_structures" and "d_text", respectively. d. Symbols in the drawing for all water structures. All structures will have a description and northing and easting coordinates. All fire hydrants will be located with a point on the side of the fire hydrant closest to the roadway. Only water valves and water manholes need elevation listed. All of the structures and text shall be on layers named "w_structures" and "w_text", respectively. e. The edge of pavement and/or back of curb on a layer named "eop" or "curb", respectively. f. A complete topographic survey with volume calculations for all detention ponds in the subdivision including all outlet structure as-built information. g. All easements and descriptions on a layer named "easements". (2) After the information submitted on the as-constructed drawing is deemed correct by engineering services and the as-constructed drawing is approved, a digital drawing referenced to state plane coordinates of the final plat or replat will be required. This drawing will be named "(name of project) final plat". (g) HOA and Condominium Association Agreements required. A copy of the stamped recorded Home Owners Association and Condominium Association Agreements providing for maintenance of any common element and/or area shown on the final plat shall be provided to the planning and development department. (h) Additional specifications. The final plat shall contain the following information: (1) Name and address of owner of record and subdivider and name and registration number of surveyor or engineer. (2) North arrow, subdivision acreage, graphic scale and date. (3) Vicinity map showing location and north point of the subdivision. (4) Location of streams, lakes, and swamps and land subject to flooding. (5) Names and addresses of owners of record of all adjoining land. (6) Bearing and distance to permanent points on the nearest existing street or benchmark or other permanent monuments. The plat shall show the location of the subdivision in relation to the U.S. government land survey by distances and bearing to a line and corner of a one-quarter section or one-quarter of a one-quarter section. Local tie for horizontal and vertical control must be made to two or more monuments in the state horizontal and vertical control monumentation system which is based on NAD 83 and NAVD 88 datums. (7) Municipal and county lines shall be shown and accurately tied to the lines of the subdivision by distance and angles when such lines traverse or are reasonably close to the subdivision. (8) Designation of land to be dedicated for a neighborhood park or open space area and designation of any commonly owned property. (9) Location of designated landscape buffers. Generally, landscape buffers shall not be part of utility, drainage or any other easement. However, on a case by case basis, the Planning, Dothan Utilities and Public Works Director's may consider allowing a portion of any required buffer to be located within an easement. (10) Exact boundary lines of the tract, determined by a field survey, giving distances to the nearest 1/100 foot and angles to the nearest second, shall be balanced and closed with an apparent error of closure not to exceed one in 10,000 feet. (11) Name of subdivision, exact locations, width, and names of all streets and alleys within and immediately adjoining the new subdivision shall be shown on the plat. (12) Street rights-of-way shall show all curvature information including central angle, tangent length, radius length and chord length and bearing. Lot lines along street rights-of-way shall show a minimum of chord length and bearing and radius length for each curved section and the length and bearing for each straight section. Supply the length and bearing across each road right-of-way that crosses the boundary of the subdivision. Any road with varying right-of-way width shall have distances shown from the center line of the existing road to the right-of-way lines on both sides of the road at both ends of the development. (13) Lot lines shall be shown with dimensions to the nearest 1/100 foot and bearings to the nearest second. (14) Lots shall be numbered by numerical order and blocks lettered alphabetically (excluding the letters "I" and "O"). (15) Location, dimensions, and purposes of any easements and any areas to be reserved or dedicated for the public or private use shall be shown on the plat. (16) Accurate location, material and description of monuments and markers shall be described on the plat. (17) Minimum building front yard setback lines for the current zoning shall be shown for all street frontages. The remaining setback lines per current zoning shall be listed in a table or list. (18) Zoning designations with zoning boundaries clearly shown. Show zoning for all adjacent properties. (19) Title shall be in the center or left side of the plat and shall state "A Final Plat of_____". Name and location of the subdivision to the one-quarter of a one-quarter section, township and range, flood zone, acreage and month and year of review in the title. (i) Surveyor's certification. A signed certification by a registered land surveyor certifying to the accuracy of the survey and the plat shall be placed on the final plat as follows: "I certify that this plat is a correct representation of the land subdivided and has been prepared in conformity with the minimum standards and requirements of law and has been calculated for closure by latitudes and departures and is found to be accurate within one (1) foot in ten-thousand (10,000) feet." By ______________________________________________ Land Surveyor, Alabama Registration Number ______________________ (j) Owner's Certification. A signed certification of ownership shall be placed on the final plat and notarized as follows: "State of Alabama, County of _______. The undersigned certifies that he is the owner of the land shown on this plat and acknowledges this plat and allotment to be his free act and deed and dedicates forever to public or private use all areas shown or indicated on this plat as streets, alleys, easements or parks." Date Owner's Name Notary Certification State of Alabama Houston County I, ________________, a notary public in and for said county and state, do hereby certify that ________________, whose name(s) ________________ signed to the foregoing certificate and who ________________ known to me, acknowledge before me on this date, that, of being informed of the contents of said certification, ________________ executed the same voluntarily on the date same bears. Given under my hand this ________ day of _________, 20________. Date Notary Public (k) Health Department certification (only if served by septic tank). A signed certification of the county health department shall be placed on the final plat as follows: [INSERT NAME OF COUNTY WHERE SUBDIVISION IS LOCATED] County Health Department on LFD's that will utilize OSS. Date Health Officer (l) Certificate of approval by the public works director. A signed certification by the public works director shall be placed on the final plat as follows: "I certify to the best of my knowledge and belief that the owner, or his agent, has completed the construction and installation of the streets, drainage, utilities and other improvements in accordance with the laws and specifications of Dothan, Alabama, or has posted a cash performance bond in lieu thereof." Date Public Works Director (m) Certificate of final approval by the planning commission. Certificate of final approval by the planning commission shall be placed on the final plat only after every item in sections 90-101 and 90-102 has been complied with and shall state the following: "I certify that all the requirements for final approval of this plat have been fulfilled in accordance with the regulations of Dothan, Alabama, and the requirements of the Planning Commission." Date Dothan Planning Commission Chairman (n) Construction certification. A signed certification by a registered professional engineer certifying to the conformity with these regulations shall be placed on the final plat as follows: "I, ___________________________, a professional engineer registered in the State of Alabama, Registration Number ________________, do hereby certify that the streets, water system, sewer system, and drainage system for __________________________ subdivision have been constructed under my general supervision in accordance with the construction plans submitted to and reviewed by the Public Works Director. I further certify that the public improvements constructed herein have been installed in accordance with the typical sections, profiles and plan details and meet minimum requirements as set out in the most current edition of the City of Dothan Code of Ordinances and shall have no adverse impact on adjacent or downstream properties. I acknowledge that in the event that the certification given herein shall be determined by the Public Works Director to be grossly incorrect, the City may hereafter refuse to accept the certification of the undersigned." NAME: _________________________ TITLE: ________________________ P.E. #: __________________________ FIRM: ________________________ DATE: __________________________
(Res. of 7-19-17; Res. of 6-20-18)
Ask a question about Dothan law
Corpus searches the Dothan sections it holds and shows the ones that match, with their citations. Free, no sign-in.
