§ 7-22 — Amendments to the 2021 International Fire Code; limits
Code of Ordinances of the City of Hoover, Alabama (Supplement 23, published 2025-05-19 (Municode online 2026-03-30).) · Hoover Municipal Code § 7-22
Corpus is an independent public-information project, not the official City of Hoover website. Stable reference: corpuslaw.us/code/34b25d2b-0259-4ad9-bb5b-b78e6b342b14
Sec. 7-22. - Amendments to the 2021 International Fire Code; limits.
(a) The following sections of the 2021 International Fire Code are hereby amended as follows. Where a conflict exists between the provisions of the International Fire Code and the following amendments, the amendments shall prevail. Section 101.1 Delete section in its entirety and replace with the following: Section 101.1 Title. These regulations shall be known as the Fire Code of the City of Hoover, hereinafter referred to as "this code." Section 111 Delete section 111 in its entirety (including sections 111.1 through 111.4 thereunder) and replace with the following: SECTION 111 APPEALS 111.1 General. Appeals of orders, decisions, and determinations made by the fire official related to the application and interpretation of this code shall be heard by the Hoover Code Appeals Board pursuant to Chapter 6, Article I, Section 6-7 of the Municipal Code of the City of Hoover and according to the appeal procedures set forth therein. Appeals shall be filed with the Hoover Code Appeals Board within twenty (20) days following the date of the decision of the code official for which appeal is sought. 111.2 Limitations on Authority. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply or an equally good or better form of construction is proposed. 111.3 Administration. The code official shall take immediate action in accordance with the decision of the Hoover Code Appeals Board. Section 112.4 Delete section in its entirety (subsection 112.4.1 shall not be affected by this deletion and shall remain a part of the Fire Code adopted by the City of Hoover) and replace with the following: Section 112.4 Violation penalties. Persons who shall violate a provision of the Fire Code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the Fire Code official, or of a permit or certificate used under provisions of the Fire Code, shall be guilty of a violation shall be guilty of an offense against the City of Hoover punishable as provided in Section 1-5 of the Municipal Code of the City of Hoover. Each day that a violation continues after due notice has been served shall be deemed a separate offense. Section 113.4 Delete section 113.4 in its entirety and replace with the following: 113.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be punished by fine as set forth Section 1-5 of the Municipal Code of the City of Hoover, Alabama. Section 308.1.4 Delete exceptions number 2 and number 3 in their entirety. Section 903.2.8 Insert the following note to the end of Section 903.2.8 (the first portion of Section 903.2.8, including subsections 903.2.8.1 through 903.2.8.4, shall not be affected by this insertion): NOTE: One (1) and two (2) family dwellings are not included within this requirement as they are excluded from the definition of "Group R, Residential" found on page 2-26 of the IFC and as such dwellings are regulated by the International Residential Code (see Section 101.2 of the International Building Code). Section B105 in Appendix B Delete Table B105.2 in its entirety and replace with the following table: TABLE B105.2 REQUIRED FIRE-FLOW FOR BUILDINGS OTHER THAN ONE- AND TWO- FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES AUTOMATIC SPRINKLER SYSTEM (Design Standard) | MINIMUM FIRE-FLOW (gallons per minute) | FLOW DURATION (hours) No automatic sprinkler system | Value in Table B105.1(2) | Duration in Table B105.1(2) Section 903.3.1.1 of the International Fire Code | 50% of the value in Table B105.1(2) a | Duration in Table B105.1(2) at the reduced flow rate Section 903.3.1.2 of the International Fire Code | 50% of the value in Table B105.1(2) a | Duration in Table B105.1(2) at the reduced flow rate For SI: one (1) gallon per minute = 3.785 L/m. a. The reduced fire-flow shall be not less than one thousand five hundred (1,500) gallons per minute. Section 903.4.2 Delete in its entirety and replace with the following: 903.4.2 Alarms. An approved audible device, located on the exterior of the building, and a minimum of one (1) interior device located in each individual tenant space, in an approved location, shall be connected to each automatic sprinkler system. Such sprinkler water flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. Section 912.2.3 Insert the following: Section 912.2.3 Hydrant Distance. An approved fire hydrant shall be located within one hundred (100) feet of the fire department connection as the fire hose lays along an unobstructed path. Section NFPA 72-2019. National Fire Alarm Code as referenced and adopted through Chapter 80 Referenced Standards of the International Fire Code NFPA 72-19. Delete Section 10.12.2 of NFPA 72-19 in its entirety and replace with the following: 10.12.2 When an occupant notification alarm signal deactivation means is actuated only audible notification appliances shall be deactivated. Visible notification appliances shall remain active until system is reset. (b) The geographic limits referred to in certain sections of the 2021 International Fire Code are hereby established as follows: 5704.2.9 .6.1 Limits in which the storage of class I and class II flammable liquids in above ground tanks outside of buildings is prohibited is as specified in the Fire Code and its referenced documents and is not limited to certain districts if all related requirements of the Fire Code and its referenced documents are met and meet approval of the fire marshal. 5706.2.4.4 Limits in which the storage of class I and class II flammable liquids in above ground tanks is prohibited is as specified in the Fire Code and its referenced documents and is not limited to certain districts if all related requirements of the Fire Code and its referenced documents are met and meet approval of the fire marshals. 5806.2 Limits in which the storage of flammable cryogenic fluids in stationary containers is prohibited is as specified in the Fire Code and its referenced documents and is not limited to certain districts if all related requirements of the Fire Code and its referenced documents are met and meet the approval of the fire marshal. 6104.2 Limits in which the storage of liquefied petroleum gas is restricted for the protection of heavily populated or congested areas is as specified in the Fire Code and its referenced documents.
(Ord. No. 22-2556, § 7.B, 3-21-22)
Ask a question about Hoover law
Corpus searches the Hoover sections it holds and shows the ones that match, with their citations. Free, no sign-in.