Code of Ordinances of the City of Huntsville, Alabama (Supp. No. 30 (codified through Ord. No. 26-196, adopted March 12, 2026) with enacted ordinances through Ord. No. 26-837 (September 24, 2026) applied from official council minutes and ordinance copies) · Huntsville Code of Ordinances, App. A, art. 62, § 62.3
Corpus is an independent public-information project, not the official City of Huntsville website. Stable reference: corpuslaw.us/code/18d45f96-146e-48aa-a120-2a11dd197ed6
62.3. - Provisions for all areas in the flood hazard districts.
The provisions of this section shall apply to all areas in the flood hazard district. 62.3.1. All new construction and substantial improvements to existing structures shall be anchored to prevent flotation, collapse or lateral movement of the structure. 62.3.2. All new construction and substantial improvements to existing structures shall be constructed with materials and utility equipment resistant to flood damage. 62.3.3. All new construction and substantial improvements to existing structures shall be constructed by methods and practices that minimize flood damage. 62.3.4. All new and replacement water supply systems shall be constructed to minimize or eliminate infiltration of floodwaters into the system. 62.3.5. New and replacement sanitary sewer systems shall be constructed to minimize or eliminate infiltration of floodwaters into the systems and exfiltration from the systems into floodwaters. 62.3.6. On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. 62.3.7. Any alteration, repair, reconstruction, or improvement to a structure on which the start of construction was begun after the effective date of this article shall meet the requirements of new construction as contained in this article. 62.3.8. Electrical, heating, ventilation, plumbing, and air conditioning equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. 62.3.9. Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces. 62.3.10. Any alteration, repair, reconstruction or improvement to a structure that is not compliant with the provisions of this ordinance shall be undertaken only if the nonconformity is not furthered, extended or replaced.
(Ord. No. 98-189, § 1(62.3), 4-7-1998)
Ask a question about Huntsville law
Corpus searches the Huntsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.