§ 57-261 — Small cell facilities in the rights-of-way; collocation, design, concealment, and aesthetic requirements

Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code § 57-261

Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/da5a84e3-96d7-4270-8572-c80db2140acf

Sec. 57-261. - Small cell facilities in the rights-of-way; collocation, design, concealment, and aesthetic requirements

(a) Collocation requirements. Small cell facilities and any new, modified, or replaced pole for the collocation of small cell facilities in the rights-of-way shall meet the following collocation requirements: (1) Collocation first. Small cell facilities may be installed on new poles only if the applicant demonstrates that (i) no reasonable collocation opportunities exist in the area where the small cell facility is proposed to be placed; or (ii) attachment to a new structure will achieve a more visually appealing design, demonstrably, more effective service coverage, or some of the public benefit not achieved by collocation. The applicant must support its claim through written evidence including, but not limited to, affidavits, correspondence, engineering report, or other written information that demonstrates that the applicant has taken all commercially reasonable actions to achieve collocation in the requested location that the applicant has pursued but has received no response or has been denied reasonable access to all potential collocation sites in the subject area (and the reasons any such denial(s)), and otherwise show that the applicant is unable to co-locate on an existing support structure. Only entities granted a certificate of convenience and necessity by the state public service commission pursuant to Code of Ala., § 37-4-28 or licensed by the Federal Communications Commission may erect new poles in the city's right-of-way. (2) New poles; collocation compatible design. New poles approved for the primary purpose of small cell facilities shall be designed to accommodate the collocation of multiple wireless providers' antennas and related equipment to the maximum extent feasible, but no less than one (1) similarly sized small cell facility. (3) Secondary use. Where small cell facilities are collocated on existing poles, use of a pole for small cell facilities shall be considered secondary to the primary function of the pole. If the primary function of a pole serving as the host site for a small cell facility becomes unnecessary, obsolete, and/or no longer in use, the pole shall not be retained for the sole purpose of accommodating the small cell facility and the small cell facility, all associated equipment, and the pole shall be removed promptly unless a SCF permit is obtained approving a hew pole for the primary purpose of small cell facilities. (4) Collocation on city street light poles or city traffic signal poles; additional requirements. a. Small cell facilities are not permitted on traffic signal poles unless the applicant can demonstrate that denial of the SCF permit will effectively prohibit the provision of telecommunications service or personal wireless service in violation of any applicable law. b. Before collocating on existing street light poles, the applicant must show structural evidence that the current pole and foundation design can meet current AASHTO design standards for wind loads with the addition of the small cell equipment. c. If poles cannot meet AASHTO requirements for wind loads with the addition of the small cell equipment, the applicant has the option of replacing the current pole with a new pole capable of supporting the existing and proposed additions. Luminaires on new poles must maintain the same height as that replaced and/or adjacent luminaires and be of the same design as the existing luminaires. d. The antenna shall be attached to the top of pole only. No mountings are allowed on the luminaire mast arms. e. Accessory equipment shall not be mounted on the pole. Accessory equipment shall be located either within or as an extension of the pole, within an underground vault, or within an enclosure/cabinet adjacent to the pole camouflaged to appear as a public amenity as shown on the concealment element plan. f. The pole design must be capable of accommodating a street light arm even if one is not installed initially. g. The application must provide analysis that the proposed small cell facility will not cause any interference with the city traffic signal systems, emergency signal control devices, other smart city applications, other signal communication components, or any other unforeseen interferences. h. Small cell facilities shall have their own power supply with disconnect and city workers and contractors shall have the ability to easily shut off radio signals and power while working on city street lights, signal system elements, poles or other facilities, if necessary. i. Any fiber or power cables supporting the small cell facility shall be labeled and housed in its own conduit(s) separating them from city fiber or power cables. (b) Pole construction, placement, height, and diameter requirements. Small cell facilities and any new, modified, or replaced pole for the collocation of small cell facilities in the rights-of-way shall meet the following requirements: (1) Pole spacing. New poles shall be no less than three hundred (300) feet from any other pole on the same side of the roadway containing small cell facilities. (2) New poles. Any new pole shall be a metal pole. (3) Pole setback. Poles shall be placed as far back from the roadway as technically feasible without any encroachment of the pole and antenna facilities onto private property unless alignment with other street poles, trees, features is more aesthetically desirable as determined by the city. (4) Pole placement. Any new poles, replacement poles and/or antenna facilities shall be placed where they: a. Do not obstruct the line of sight for transportation, vehicular, or pedestrian traffic; b. Do not obstruct the clear zone or have a breakaway design; c. Comply with the Americans with Disabilities Act (ADA), similar federal or state standards, city construction and sidewalk clearance standards and applicable laws, in order to provide a clear and safe passage within the rights-of-way. Further, the location of any replacement or new pole must: be physically possible, comply with applicable traffic uniform warrants, not interfere with utility or safety fixtures (e.g., fire hydrants, traffic control devices), and not adversely affect the public health, safety, or welfare; and d. Any replacement pole shall be placed as close to the original pole as possible, and no more than five feet from the existing pole location. (5) Pole heights. The height of poles above the ground including the antennas shall: a. Be fifty (50) feet or less in non-residentially zoned areas; b. Be forty (40) feet or less in residentially zoned areas with above ground power; and c. Be thirty-five (35) feet or less in residentially zoned areas with underground power. (6) Metal pole construction requirements. a. Structural/foundation design. The pole and pole foundation shall be designed in accordance with the most current version of American Association of State Highway Transportation Officials (AASHTO) Standard Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals; b. Material. The pole material shall be aluminum, hot dipped galvanized steel, or other corrosion resistant metal; c. Diameter. The pole diameter shall be twelve (12) inches maximum at existing grade unless otherwise approved by the city not including the base of the pole; and d. Pole coloring. The pole shall be black in color unless another color scheme is determined to be more aesthetically desirable by the city. (7) Wooden pole construction requirements for collocation. a. The existing wooden pole diameter shall be sixteen (16) inches maximum at existing grade unless otherwise approved by the city; and b. The grantee must show structural evidence that the existing wooden pole and foundation design can meet the current wind load requirements based on NESC extreme wind category with the addition of the small cell facilities. (8) Decorative poles; additional requirements. a. Decorative poles shall be metal poles only; b. Antennae shall be mounted on top of the pole only; c. Accessory equipment shall be located either within or as an extension of the pole, within an underground vault, or within an enclosure/cabinet adjacent to the pole camouflaged to appear as a public amenity as shown on the concealment element plan; and d. Aesthetics. Pole shall match the design of decorative poles in the area. (c) Antenna and accessory equipment size, location, and dimensional restrictions. (1) General. The applicant shall minimize to the extent possible the antenna and accessory equipment space and shall use the smallest amount of enclosure possible to fit the necessary equipment. (2) Vertical clearance. All antennae and accessory equipment shall be a minimum of ten (10) feet above the existing adjacent grade and shall not be not be installed in such a manner as to obstruct the line of sight or pedestrian paths. (3) Mounting/projection off pole. Unless the applicant can demonstrate that more space is needed to be technically feasible, all antennae and accessory equipment including the enclosure shall be as close to the pole as possible and shall be mounted no greater than four (4) inches off the pole and the furthest point of all antennae and accessory equipment including the enclosure shall not project more than twenty-eight (28) inches from the face of the pole. (4) Antenna size and dimensional restrictions. Unless the applicant can demonstrate that more space is needed to be technically feasible, the size of each antenna shall: a. Be no greater than three (3) cubic feet; b. In the case of top mounted canister antennas, be no greater than six (6) feet in height and share a reasonably similar diameter as the top of the pole not to exceed sixteen (16) inches; c. In the case of omnidirectional antennas, be no greater than four (4) feet in height; and d. In the case of microwave dishes, be no greater than two (2) feet in diameter and no more than three (3) microwave dishes per pole. (5) Accessory equipment size and dimensional restrictions. Unless the applicant can demonstrate that more space is needed to be technically feasible, the size of accessory equipment shall: a. Be no greater than twenty-eight (28) cubic feet total considering accessory equipment for all small cell facilities attached to the pole collectively not including the electrical equipment; b. Be designed to be long and narrow along the pole with a reasonably greater vertical dimension than horizontal; and c. Be no greater than twenty-four (24) inches in width. (6) All antenna equipment, excluding the antenna, is to be housed inside the pole, ground vault, an approved ground mounted cabinet, or properly camouflaged. (7) Antennas, equipment enclosures, and ancillary equipment, conduit and cable shall not dominate the structure or pole upon which they are attached. (d) Concealment and objective aesthetic requirements. Small cell facilities and any new, modified, or replaced pole for the collocation of small cell facilities in the rights-of-way shall meet the following concealment and aesthetic requirements: (1) Collocated replacement poles. Match neighboring pole design. Any pole replaced for the purposes of collocation shall substantially conform to the design of the pole it is replacing or the neighboring pole design standards utilized within the contiguous right-of-way. (2) Special districts. In Historic Districts, any new or replacement poles shall be metal Poles. If the neighboring poles are decorative poles, then any new or replacement pole shall be decorative poles of matching dimensions and design. (3) Pole material reservation. The City reserves the right to require or allow certain pole material types. (4) Concealment within poles. With the exception of wooden poles, all conduit, cables, wires and fiber must be routed within the pole. (5) Concealment outside of poles. The full concealment of antennae, accessory equipment, and all conduit, cables, wires and fiber is required and shall meet the following requirements: a. Accessory equipment shall be covered with an enclosure; b. Canister antennae shall be placed to look as if it is an extension of the pole. All cables shall be concealed either within the canister antenna or within a sleeve between the antenna and the pole; c. Spools and/or coils of excess fiber optic or coaxial cables or any other wires shall not be stored on the pole except completely within the approved enclosures or cabinets; and d. All cables, wires, and fiber associated with the small cell facility shall be flush-mounted to the support structure where internal installation is not feasible and shall be shrouded or encased in a cover or conduit. (6) Antenna and accessory equipment coloring. The antenna, accessory equipment, and all visible attachments, equipment, and hardware shall be colored to match the pole unless another color scheme is determined to be more aesthetically desirable by the City. (7) The preferred location of a small cell facility on a pole is the location with the least visible impact. (8) Ground-mounted equipment in the rights-of-way is prohibited, unless such facilities are placed underground or the applicant can demonstrate that pole-mounted or undergrounded equipment is technically infeasible. If ground-mounted equipment is necessary, then the applicant shall submit a concealment element plan. Generators located in the rights-of-way are prohibited. (9) The City may consider the cumulative visual effects of small cell facilities mounted on poles within the rights-of-way when assessing proposed siting locations so as to not adversely affect the visual character of the City. This provision shall not be applied to limit the number of permits issued when no alternative sites are reasonably available nor to impose a technological requirement on the applicant. (10) These design standards are intended to be used solely for the purpose of concealment and siting. Nothing herein shall be interpreted or applied in a manner which dictates the use of a particular technology. When strict application of these requirements would unreasonably impair the function of the technology chosen by the applicant, alternative forms of concealment or deployment may be permitted which provide similar or greater protections from negative visual impacts to the streetscape. (e) Electrical service and equipment requirements. (1) All electronic service equipment shall be installed in accordance with the applicable provisions of the National Electrical Safety Code of the National Bureau of Standards and National Electrical Code of the National Board of Fire Underwriters. (2) An electric meter, if required, will be support structure-mounted where feasible to the extent authorized by the support structure owner and electric utility. (3) A separate electrical permit is required by the city for the electrical service. (4) No equipment shall be operated so as to produce noise in violation of the City Code. (f) Cable strung small cell facilities. Small cell facilities mounted on cables strung between existing utility poles shall conform to the following standards: (1) Each strand-mounted facility shall not exceed three cubic feet in volume; (2) Only one (1) strand-mounted facility is permitted between any two (2) existing poles; (3) The strand-mounted devices shall be placed as close as possible to the nearest utility pole, in no event more than five (5) feet from the pole unless a greater distance is technically necessary or is required by the pole owner for safety clearance; (4) No strand-mounted device shall be located in or above the portion of the roadway open to vehicular traffic; (5) Ground-mounted equipment to accommodate a shared mounted facility is not permitted except when placed in preexisting equipment cabinets; (6) Pole-mounted equipment shall comply with the all other requirements this section; (7) Such strand-mounted devices must be installed to cause the least visual impact and without excess exterior cabling or wires (other than the original strand); and (8) Strand-mounted facilities are only permitted on poles that have existing overhead wirelines. (g) Signage requirements. (1) A plate no larger than four (4) inches by six (6) inches with the location of the pole and the pole owner's name, contact information, and emergency telephone number shall be permanently affixed to the pole or shroud. (2) No signage, message or identification other than the manufacturer's identification or such other identification required by applicable law is allowed to be displayed on any antenna or equipment enclosure. Any permitted signage shall be located on the equipment enclosures and be of the minimum amount possible to achieve the intended purpose (no larger than four (4) by six (6) inches); provided, that banners may be permitted as concealment element techniques where appropriate.

(Ord. No. 57-009-2021, art. 2, 3-2-21)

Ask a question about Mobile law

Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.