§ 64-10-9 — Sign permits
Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code § 64-10-9
Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/8bbfe348-db8d-4ec1-bc35-abb0816752bf
Sec. 64-10-9. - Sign permits.
A. Application. An application for a sign permit shall include the following information: 1. Sign location (address and parcel number); 2. Name and contact information for sign fabrication contractor and sign installation contractor; 3. Name and contact information of sign owner and all property owners; 4. Type of business; 5. The type of sign, based on the sign classifications described in this chapter (articles 4, 13 and appendix A), and as defined in article 8; 6. Sign dimensions, including: (a) Height from ground level to top of sign; (b) Height from ground level to bottom of sign; (c) Width and height of sign face; and (d) Sign area (total and for each sign face). 7. Drawings. (a) Location sketch; (b) Submission of documentation certifying that the new or enlarged sign structure complies with the currently adopted International Building Code (IBC), which may require the submission of plans signed and sealed by a properly licensed professional engineer. (c) A scaled drawing showing the entire sign and support structure, with dimensions and renderings. (d) For freestanding signs, a site plan showing: (1) The sign location; (2) Setbacks from the public right-of-way and front property line; (3) Sign orientation; (4) Distance from all streets, rights-of-way and other structures on the site; and (5) Location of any existing or proposed trees within fifteen (15) feet. (e) For wall signs, a sketch and square footage of building wall. 8. Total cost of the sign including materials, labor and installation. 9. If the contract(s) valuation is over fifty thousand dollars ($50,000.00), a State of Alabama General Contractor's Specialty License must be provided. 10. If an electrical permit is required by the currently adopted National Electrical Code, the required electrical permit must be obtained prior to the issuance of a sign permit. This includes the submission of Underwriters Laboratory (UL) file number of fabricator, UL file number of sign, nits (if electronic) and electrical permit number. 11. The sign permit shall become null and void unless construction of the sign has been substantially completed within six (6) months from the date on which the permit was issued. In the event a permit becomes null and void after the expiration of six (6) months, the permittee shall be required to reapply for a permit for that site and pay another permit application fee. B. Illuminated signs/electronic message centers. 1. In addition to the requirements of subsection A above, the following information is required: (a) Site plan depicting the straight line distance between the proposed sign and residentially zoned property. (b) Submission of documentation that the sign is equipped with an ambient light monitor. (c) Written certification from the sign manufacturer certifying that the light intensity of the sign is compliant with article 4. C. Off-premise signs. This includes electronic or digital off-premise signs, and the conversion of any existing off-premise sign to electronic or digital technology. 1. In addition to the requirements of subsections A and B above, the following information is required: (a) Copy of a deed, lease or other agreement by which the applicant has the right to erect, use or maintain the proposed sign at the stated location. (b) The distance from the proposed sign to closest off-premise sign on the same side of the street and on the opposite side of the street. (c) Distance from proposed sign to closest residentially zoned (R-1, R-2 or R-3) property. (d) If the proposed sign is an electronic sign, the location of all other electronic off-premise signs within a radius of one mile of the proposed location, must be provided. (e) If the proposed sign is an electronic sign, written certification from the sign manufacturer certifying that the light intensity of the sign has been preset not to exceed the illumination levels established by this section, and that the preset intensity level is protected from end user manipulation by password protected software or other approved method is required. (f) Identification of the signs that will be removed within six (6) months of the issuance of the sign permit as required by this section. (g) A permit application fee of two hundred fifty dollars ($250.00) per structure shall be paid by each person or corporation seeking a sign permit under this section. This fee shall be in addition to, and not in lieu of, any other fees or licenses required. D. Springhill Overlay, Downtown Development District, and Historic Districts. 1. In addition to the requirements of subsection A above, the following information is required: (a) How the sign will be mounted. (b) Sign materials. (c) Type of sign lighting. (d) Linear front footage of principle building. (e) Scaled colored renderings of the requested sign. (f) Photographs with dimensions and photographs of the building. (g) Certificate of appropriateness is required for all signs in Historic Districts. (h) Approval of consolidated review committee for signs in the Downtown Development District.
(Ord. No. 64-017-2022, 7-12-22)
Ask a question about Mobile law
Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.
