§ 5-652 — Specific technical standards
Code of Ordinances of the City of Montgomery, Alabama (Supp. No. 27: codified through Ordinance No. 4-2026, enacted March 5, 2026) · Montgomery City Code § 5-652
Corpus is an independent public-information project, not the official City of Montgomery website. Stable reference: corpuslaw.us/code/cc9b0e9b-7d04-4d3e-9baf-35ab4d4e0e54
Sec. 5-652. - Specific technical standards.
In all special flood hazard areas designated as A, AE, AH (with engineered or estimated BFE), the following provisions are required: (1) Residential and non-residential structures. Where BFE data is available, new construction and substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than two feet above the base flood elevation (also referred to as the design flood elevation). Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of division 4, subsection 5-652(4). Manufactured homes must also meet the two feet freeboard requirement. (2) Non-residential structures. New construction and substantial improvement of any non-residential structure located in AE or AH zones, may be floodproofed (dry) in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to at least two feet above the base flood elevation (herein after referred to as the design flood elevation), with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. a. A professional engineer, who is licensed to practice in the State of Alabama, or licensed architect, who is registered to practice in the State of Alabama, shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with the standards in ASCE-24 (for dry floodproofing) or other compatible standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and in division 3, subsection 5-638(8). b. A record of such certificates, which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained with the official permitting records for the structure and kept in-perpetuity. c. Any non-residential functionally dependent structure (as defined in section 5-605) that cannot meet the standards stated in division 4, subsection 5-652(2)(a) shall require a variance to be issued in accordance with division 5, subsections 5-673(3) and 5-674(1). (3) Critical facilities. Construction of new and substantially improved critical facilities shall be located outside the limits of the SFHA (one percent annual chance floodplain). Construction of new critical facilities shall be permissible within the SFHA only if no feasible alternative site is available and access to the facilities remains available during a 0.2 percent chance flood. a. Critical facilities constructed within the SFHA shall have the lowest flood elevated four feet above the base flood elevation at the site (or to the 0.2 percent chance flood elevation, whichever is greater). b. Floodproofing and sealing measures must be implemented to ensure that any and all on-site toxic substances will not be displaced by or released into floodwaters. c. Multiple access routes, elevated to or above the 0.2 percent flood elevation, shall be provided to all critical facilities to the maximum extent possible. d. Critical facilities must be protected to or above the 0.2 percent chance flood and must remain operable during such an event. 1. The community's flood response plan must list facilities considered critical in a flood 2. Other facilities in low-risk flood zones that may also be needed to support flood response efforts must be included on the critical facility list. (4) Enclosures for elevated buildings. All new construction and substantial improvements of existing structures (residential and non-residential) that include any fully enclosed area below the BFE, located below the lowest floor formed by the foundation and other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of flood waters. a. Designs for complying with this requirement must either be certified by a professional engineer, who is licensed to practice in the State of Alabama, or a licensed architect, registered to practice in the State of Alabama, or meet the following minimum criteria: 1. Provide a minimum of two openings for each enclosed area having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding (if a structure has more than one enclosed area below the BFE, each shall have openings on exterior walls); 2. Openings shall be in at least two walls of each enclosed area (includes areas separated by interior walls); 3. The bottom of all openings shall be no higher than one foot above grade; 4. Openings may be equipped with screens, louvers, valves and other coverings or devices provided that they permit the automatic entry and exit of floodwaters in both directions without impeding or blocking flow and shall be accounted for in determination of the net open area; and 5. Openings meeting the requirements of subsections (4)(a)(i)—(iv) that are installed in doors are permitted. b. So as not to violate the "lowest floor" criteria of this article, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage, or access to the elevated area. c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. d. All interior walls, ceilings and floors below the BFE shall be unfinished and/or constructed of flood damage-resistant materials. This practice is also referred to as "wet floodproofing." The definitions for "flood damage-resistant materials" and "wet floodproofing" are included in section 5-605. e. Mechanical, electrical, or plumbing devices shall be installed not less than two feet above the BFE. The interior portion of such enclosed area(s) shall be void of utilities except for essential lighting and power, as required, that are watertight or have otherwise been floodproofed. (5) Standards for manufactured homes and recreational vehicles where base flood elevation data is available. a. Require that all manufactured homes placed or substantially improved: 1. Outside of a manufactured home park or subdivision, 2. In a new or substantially improved manufactured home park or subdivision, 3. In an expansion to an existing manufactured home park or subdivision, or 4. In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated two feet or more above the BFE and be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. b. Require that all manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision that are not subject to the provisions of subsection (4)(a) be elevated so that either: 1. The lowest floor of the manufactured home is two feet or more above the BFE; or 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above the highest adjacent grade and be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. 3. Concrete block piers (and other foundation systems) are to be designed in accordance with the Code of Federal Regulations Title 24, Part 3285 and with the specifications in FEMA P-85: Protecting Manufactured Homes from Floods and Other Hazards - A Multi-Hazard Foundation and Installation Guide. The § 3285.306 Design procedures for concrete block piers and FEMA P-85 (Table SP-1.1), specify that the maximum allowable pier height (measured from top of grade) for concrete piers to be five feet. 4. The chassis and its supporting equipment are to be above the pier or other foundation. The areas below the chassis must be constructed with flood-resistant materials. All utilities and mechanical equipment must be elevated to a minimum of three feet above the highest adjacent grade. Any utility and mechanical components that must be below the BFE must be made watertight to that same elevation to meet the standards in division 4, subsection 5-651(5). c. Require that all recreational vehicles placed on sites must either: 1. Be on the site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use on its wheels or jacking system; 3. Be attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached structures or additions; or 4. Must meet all the requirements for "new construction," including the anchoring and elevation requirements of division 4, section 5-652, provisions (4)(a) and (4)(b). (6) Standards for manufactured homes where no base flood elevation exists. a. Require that all manufactured homes to be placed within a zone A area on the FIRM shall be installed using methods and practices which minimize flood damage. b. Manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. c. The manufactured home chassis must be supported by reinforced piers or other foundation elements of at least equivalent strength such that the bottom of the chassis and its supporting equipment be no less than 36 inches and up to a maximum 60 inches (five feet) above the highest adjacent grade and be securely anchored to an adequately anchored foundation system. d. The areas below the chassis must be constructed with flood-resistant materials. All utilities and mechanical equipment must be elevated to a minimum of three feet above the highest adjacent grade. Any utility and mechanical components that must be below the BFE must be made watertight to that same elevation to meet the standards in division 4, subsection 5-651(5). (7) Require, until a regulatory floodway is designated, that no new construction, substantial improvements, or other development (including fill) shall be permitted within zones A and AE on the City of Montgomery's FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, would not result in any increase in BFEs during the occurrence of the base flood discharge. A registered professional engineer must provide supporting technical data and certification (no-rise certificate) to FEMA for the proposed floodway encroachment. The no-rise certificate must be submitted to the floodplain administrator with the development permit (including a site plan showing the current and proposed floodway alignment) for approval. (8) Accessory and agricultural structures. When an accessory structure meets the requirements outlined below, these structures may be wet-floodproofed and do not have to be elevated to two feet above the BFE as required in section 5-605. A permit shall be required prior to construction or installation of any accessory structures and any agricultural structures built below the BFE and the following provisions apply: a. Must be adequately anchored to prevent flotation, collapse, or lateral movement; b. Must be designed with an unfinished interior and constructed with flood damage resistant materials below the BFE as described in division 4, subsection 5-652(4); c. Must have adequate flood openings as described in division 4, subsection 5-652(4); d. Must be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters; e. Must comply with the requirements for development in floodways in accordance with division 4, section 5-653; f. Must elevate any mechanical and other utility equipment in or servicing the structure to or above the BFE or must be floodproofed in accordance with division 4, section 5-651; g. Prohibit storage of any hazardous or toxic materials below the BFE. h. Permits for small accessory structures may be issued to provide wet floodproofing measures in accordance with the standards described in subsections (i) through (iv) below without requiring a variance. Before issuing permits for small accessory structures, the floodplain administrator must verify: 1. Use is limited to parking of vehicles or storage; 2. Size is less than or equal 600 square feet for all A zones; 3. Structures are a minimal investment and have a low damage potential with respect to the structure and contents; 4. Structures will not be used for human habitation; 5. Structures comply with the wet floodproofing requirements in division 4, subsection 5-652(4). i. Permits for accessory structures larger than the size allowed for in subsection (8)(h) above, shall require a variance to be granted on a case-by-case basis in accordance with division 5. Variances shall not be granted for entire subdivisions for accessory structures. j. Permits for new construction of all agricultural structures shall require a variance to be granted on a case-by-case basis in accordance with division 5. (9) Underground and aboveground storage (liquid and gas) tanks. Tanks and tank inlets, fill openings, outlets, and vents that are located below the BFE shall be designed, constructed, installed, and anchored to resist all flood-related and other loads, including the effects of buoyancy, during flooding up to and including the base flood, and without release of contents into floodwaters or infiltration of floodwaters into the tanks. a. A permit that includes floodplain development shall be required prior to construction or installation of any underground or aboveground tanks (including their foundation and support systems) located within a SFHA or other high risk flood hazard area. b. Loads on underground tanks and aboveground tanks exposed to flooding shall be determined assuming at least 1.5 times the potential buoyant and other flood forces acting on the empty tank. c. Where required, tanks and associated piping shall be designed and installed to resist local scour and erosion during the base flood. In other high risk flood hazard areas, the determination of flood-related loads shall take into consideration the eroded ground elevation. d. Aboveground tanks located in zone A/AE flood hazard areas shall be either: 1. Two feet above the BFE on platforms or structural fill; 2. Elevated two feet above the BFE where attached to structures, and the foundation system supporting the structures shall be designed to accommodate any increased loads resulting from the attached tanks; 3. Permitted below the BFE where the tank and its foundation are designed to resist all flood-related loads, including floating debris; or 4. Permitted below the BFE where the tank and its foundation are designed to resist flood loads and are located inside a barrier designed to protect the tank from floating debris. e. Aboveground tanks shall be two feet above the BFE on platforms that conform to the foundation requirements, in accordance with ASCE 24-24, Section 9.7.1. Aboveground tanks shall not be permitted beneath elevated structures or attached to structures at elevations less than two feet above the BFE. f. Underground tanks located within special flood hazard areas (SFHAs) shall be designed, constructed, and anchored to prevent flotation, collapse, or lateral movement resulting from flood forces, including hydrostatic and hydrodynamic loads and the effects of buoyancy. Where required by ASCE 24-24, the determination of flood-related loads shall take into consideration the eroded ground elevation. g. Tank inlets, fill openings, outlets, and vents shall be: 1. Located two feet above the BFE, or fitted with watertight covers designed to prevent the inflow of floodwater or the outflow of tank contents during the base flood (one-percent-annual-chance) event; and 2. All such components shall be anchored and designed to resist flood forces, including hydrostatic and hydrodynamic loads and buoyancy, in accordance with ASCE 24-24, as applicable. (10) Structures and sites for the storage or production of hazardous substances. Require that all outdoor storage sites, new construction and substantial improvements to be used for the production or storage of hazard substances (as defined in section 5-605) which are located in the special flood hazard area shall be built in accordance with all applicable standards in this article in addition to the following requirements: a. No structures containing hazardous substances shall be permitted for construction in a floodway; b. Residential structures shall have the area in which the hazard substances are to be stored elevated or dry floodproofed a minimum of two feet above the BFE; c. Non-residential structures shall be permitted to be built below the BFE in accordance with division 4, subsection 5-652(2) such that the area where the hazard substance production or storage is located will be: 1. Elevated or designed and constructed to remain elevated to the 500-year flood, or completely dry to at least two feet above the BFE, whichever is greater; and 2. Designed to prevent pollution from the storage containers, structure, or activity during the course of the base flood. d. Any solid, liquid, or gas storage containers of hazardous substances and any associated mechanical, electrical, and conveyance equipment shall be watertight and shall be properly anchored and protected from the hydrostatic and hydrodynamic forces of flood waters and debris carried by the base flood. (11) Construction of fences. New and replacement fences may be allowed in flood hazard areas if they do not act as a flow boundary and redirect the direction of flow, collect flood debris and cause blockages, cause localized increases in flood levels, or if damaged, become debris that may cause damage to other structures.
(Ord. No. 4-2026, 3-5-2026)
Ask a question about Montgomery law
Corpus searches the Montgomery sections it holds and shows the ones that match, with their citations. Free, no sign-in.
