Sec. 15-34. - Gas distribution system.

(a) General. Gas equipment and installations within a mobile home park shall be designed and constructed in accordance with the provisions of this section, as well as the provisions of the gas code of the city. (b) Required gas supply. The minimum hourly volume of gas required at each mobile home lot outlet or any section of the mobile home park gas piping shall be calculated as follows: Natural | L.P.G. For the most remote mobile home lot outlet on any branch or main ..... | 125 CFH | 50 CFH For the second most remote outlet on any branch or main ..... | 100 CFH | 40 CFH For the third most remote outlet on any branch or main ..... | 75 CFH | 30 CFH After the third most remote outlet, subsequent branch or main line loadings may be computed using a value of fifty (50) cubic feet per hour for natural gas and twenty (20) cubic feet per hour for liquefied petroleum gas. (c) Installation. All gas piping installed below ground shall have a minimum earth cover of eighteen (18) inches. Gas piping shall not be installed under any mobile home. (d) System shutoff valve. A readily accessible and identified shutoff valve controlling the flow of gas to the entire gas piping system shall be installed near to point of connection to the service piping or supply connection of the liquefied petroleum gas tank. (e) Mobile home lot shutoff valve. Each mobile home lot shall have an approved gas shutoff valve installed upstream of the mobile home lot gas outlet and located on the outlet riser at a height of not less than four (4) inches above grade. Such valve shall not be located under any mobile home. Whenever the mobile home lot outlet is not in use, the outlet shall be equipped with an approved cap or plug to prevent accidental discharge of gas. (f) Mobile home connector. Each mobile home shall be connected to the mobile home lot outlet by an approved three-quarters (¾) inch mobile home connector not more than six (6) feet in length. Approved pipe and fittings may be used between the flexible connector and the mobile home lot gas outlet when the distance between the mobile home lot gas outlet and the mobile home gas service connection exceeds that required to make a safe installation with only a mobile home connector. (g) Mechanical protection. All gas outlet risers, regulators, meters, valves or other exposed equipment shall be protected from mechanical damage by vehicles or other causes. (h) Location. The mobile home gas connection shall be installed at the edge of the mobile home stand, approximately thirty (30) feet from the front of such stand; and located as not to terminate beneath the mobile home.

(Code 1962, § 21A-35)

Ask a question about Tuscaloosa law

Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.