Sec. 25-127. - Off-street loading standards.

a. Minimum number of off-street loading berths. 1. Except as provided in subsection 2. below, all new development involving the routine vehicular delivery or shipping of goods, supplies, or equipment to or from the development shall provide a sufficient number of off-street loading berths to accommodate the delivery and shipping operations of the development's uses in a safe and convenient manner. Table VI-8: minimum number of off-street loading berths, sets forth the minimum number of loading berths for the different principal uses. For proposed uses not listed in table VI-8: minimum number of off-street loading berths, the director of planning shall establish a minimum number of loading berths based on the use most similar to the proposed use. Table VI-8: Minimum Number of Off-Street Loading Berths Principal use | Size | Minimum number of loading berths Multifamily dwelling | Between 100 and 300 dwelling units | 1 Each additional 200 dwelling units or major fraction thereof | add 1 Multifamily student dwelling | Between 200 and 400 bedrooms | 1 Each additional 400 bedrooms or major fraction thereof | add 1 Hospital, medical or dental clinic, nursing home, business services use, food and beverage services use, hotel use, and theater or auditorium | At least 10,000 and up to 100,000 sf | 1 Each additional 100,000 sf | add 1 Retail sales and services, or a mix of retail sales and services with business services use, food and beverage services use, hotel use, and theater or auditorium | At least 5,000 but less than 20,000 sf | 1 At least 20,000 but less than 120,000 sf | 2 Each additional 80,000 sf | add 1 Warehousing, freight movement, and wholesale sale uses | Less than 15,000 sf | 1 At least 15,000 but less than 50,000 sf | 2 At least 50,000 sf | 3 Each additional 50,000 sf | add 1 All other industrial uses | Less than 50,000 sf | 2 At least 50,000 but less than 150,000 sf | 4 At least 150,000 but less than 250,000 sf | 5 At least 250,000 but less than 500,000 sf | 6 Each additional 100,000 sf | add 1 2. The director of planning may approve a reduction in the minimum number of off-street loading berths required by table VI-8: minimum number of off-street loading berths if the applicant submits a study prepared by a registered professional engineer or landscape engineer that uses professionally accepted methods of transportation engineering which demonstrates an appropriate number of loading facilities for the development that is different from what is required by this ordinance. b. Dimensional standards for loading areas and berths. 1. Each loading berth shall be of sufficient size to accommodate the types of vehicles likely to use the loading area. The minimum loading berth size that presumptively satisfies loading berth needs is least twelve (12) feet wide and forty-five (45) feet long in general industrial, distribution, or warehousing uses (see figure VI-3: loading area configuration). For all other uses, a berth as short as thirty-three (33) feet may be allowed. The director of planning may require a larger loading berth or allow a smaller loading berth on determining that the characteristics of the particular development warrant such increase or reduction and the general standard is met. 2. Each loading berth shall have at least fifteen (15) feet of overhead clearance. c. Location and arrangement of loading areas. 1. Except in the D, DP, DHE, R, UC, and NC districts, to the maximum extent practicable, loading areas should be located to the rear of the building housing the use they serve (see figure VI-3: loading area configuration). In the D, DP, DHE, R, UC, and NC districts, loading areas shall be located to the rear or side of the building housing the use they serve. 2. Each loading berth should be located adjacent to the building's loading doors, in an area that promotes its practical use, and be accessible from the interior of the building it serves. 3. Each loading berth shall be directly accessible from a street or alley without crossing or entering any other required off-street loading space. 4. Each loading berth shall be arranged so that all vehicle maneuvers for loading and unloading occur entirely within the property lines of the site and do not obstruct or interfere with use of any parking space, parking lot aisle, or public right-of-way. 5. Each loading berth shall be screened from view from the right-of-way with, at a minimum, screening equivalent to the requirement for the perimeter of parking lots in section 25-132(c), parking lot perimeter landscaping standards. Figure VI-3: Loading Area Configuration [image omitted; see the official code]

(Ord. No. 9572, § 2, 12-17-24)

Ask a question about Tuscaloosa law

Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.