For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 25-133 — Buffers

Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 25-133

Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/15d3d3c0-e7db-4c20-aaae-3cdcad5fccba

Sec. 25-133. - Buffers.

a. Purpose. Buffers on the perimeters of properties are provided to protect land uses from the traffic, noise, glare, trash, activity, vibration, odor, visual disorder, and other harmful or noxious effects likely to be emitted by or associated with an adjacent more intense land use. b. Applicability. 1. General. Unless exempted in accordance with subsection 2. below, the standards in this subsection shall apply to: i. All new development and re-development; and ii. All expansion or enlargement of gross floor area of a building that existed on January 1, 2025 by more than fifty (50) per cent. 2. Exemptions. Development in the mixed residential university (MRU), multifamily residential university (MFRU), institutional university (IU), downtown (D), downtown perimeter (DP), downtown historic edge (DHE), riverfront (R), and university commercial (UC) districts is exempted from the requirements of this subsection. c. Buffer options. Table VI-11: buffer options, defines three (3) types of buffers based on their function, width, and minimum screening requirements. Each buffer type includes two (2) options for plantings and other screening. The width of the buffer under one of the options, indicated in the top row of each buffer type in table VI-11, may be reduced by a wall or berm, provided that the director of planning determines that the buffer is adequate to screen the incompatible uses in locations where the buffer width is reduced. If the director of planning determines that the presence of utility or access easement or lines within the buffer will make it impractical for the buffer to accomplish its purpose, the director of planning may reduce the buffer width and require additional tree planting or the addition of an opaque wall in accordance with subsection e.6. below. Table VI-11: Buffer Options Buffer type/image | Description | Option 1 | Option 2 Type I: Industrial | 50 ft [image omitted; see the official code] | This buffer functions as an opaque screen from the ground to a height of at least 35 feet upon full maturity of the trees. This type of buffer prevents visual contact between uses and creates a strong separation. | 4 canopy trees and 4 understory trees, and 90 shrubs per 100 linear feet Type A: Opaque | 40 ft | 20 ft [image omitted; see the official code] | This buffer functions as an opaque screen from the ground to a height of at least 35 feet upon full maturity of the trees. This type of buffer prevents visual contact between uses and creates a strong separation. | 4 canopy trees and 4 understory trees, and 90 shrubs per 100 linear feet | 5 canopy trees and 5 understory trees, and 100 shrubs per 100 linear feet, and a wall (see subsection e.6. below) Type B: Semi-Opaque | 35 ft | 20 ft [image omitted; see the official code] | This buffer functions as semi-opaque screen from the ground to at least a height of 30 feet, upon maturity of the trees. | 4 canopy trees and 4 understory trees, and 60 shrubs per 100 linear feet | 3 canopy trees and 6 understory trees, and 80 shrubs per 100 linear feet, and a wall (see subsection e.6. below) Type C: Aesthetic | 20 ft | 10 ft [image omitted; see the official code] | This buffer functions as an intermittent visual obstruction from the ground to 20 feet upon maturity of the trees, and creates the impression of spatial separation without eliminating visual contact between uses. | 2 canopy trees and 6 understory trees and 60 shrubs per 100 linear feet | 2 canopy trees and 8 understory trees, 80 shrubs per 100 linear feet, and a wall (see subsection e.6. below) d. Buffer types. 1. The width of a buffer and the required quantity and type of plantings varies based on the nature of the potentially adjacent uses. Table VI-12: buffer types, establishes the type of perimeter buffer required between two adjacent land uses. The buffer types are described above in table VI-11: buffer options. 2. Where parking lot landscaping requirements overlap with these buffer requirements, they shall be counted toward the buffer requirements if the minimum of both standards are met. 3. A buffer is not required if properties are separated by an improved right-of-way that is twenty (20) feet or greater in width. Table VI-12: Buffer Types Existing use type or, if vacant, zoning district of adjoining land | Proposed use [1] [2] All household living uses (except triplexes, quadplexes, multifamily dwellings; multifamily student dwellings; or mobile homes) | Triplexes, quadplexes, multifamily dwellings; multifamily student dwellings; mobile homes; all group living uses; all institutional uses (except correctional facilities, hospitals, rail or bus passenger stations, railroad terminals, and truck terminals) | All commercial uses; hospitals; rail or bus passenger stations | All industrial uses; correctional facilities; railroad terminals; truck terminals; major utilities All household living uses (except triplexes, quadplexes, multifamily dwellings; multifamily student dwellings; or mobile homes) Vacant land districts: OS, CN, SFR-E, LR, SFR-1, SFR-2, SFR-3, SFR-4 R | None | C [3] | A | I Triplexes, quadplexes, multifamily dwellings; multifamily student dwellings; mobile homes; all group living uses; all institutional uses (except correctional facilities, hospitals, rail or bus passenger stations, railroad terminals and truck terminals) Vacant land districts: LMF, SFR-4 R, MR-1, MR-2, MFR, MHR, IP, ISP, NC | None | None | B | I All commercial uses; hospitals; rail or bus passenger stations Vacant land districts: LC, GC, HC, IL | None | None | None | C All industrial uses; correctional facilities; railroad terminals; truck terminals; major utilities Vacant land districts: IG, IH | None | None | C | None Notes: [1] The letters in the cell reference the type of buffer required between the uses; see table VI-11: buffer options. [2] Athletic fields (softball, baseball, football and soccer fields; basketball, tennis, and pickleball courts; and comparable uses) shall provide a type C buffer in all districts. [3] No buffer is required between a townhouse dwelling and a single-family detached dwelling. e. Buffer installation. 1. Adjacent to vacant parcel. Where a developing parcel is adjacent to a vacant parcel, the developing parcel shall provide fifty (50) per cent of the buffer required adjacent to the vacant parcel. 2. Adjacent to existing land use. Where a developing parcel is adjacent to an existing use, the developing parcel shall provide the full buffer required adjacent to the existing use in accordance with this section, unless a portion or all of a buffer that complies with the standards of this section already exists on the adjacent lot. Where all or part of a buffer exists but the buffer does not fully comply with the standards of this section, the developing parcel shall be responsible for providing all the additional planting material necessary to comply with this section. 3. Location of buffers. Buffers required by this section shall be located along the outer perimeter of the lot or site and shall extend to the lot boundary line or right-of-way line; however, the buffer may be located along shared access or utility easements between parcels in nonresidential development. 4. Trees. Required canopy and understory trees shall be spaced to achieve the screening goals and meet the standards in this subsection. 5. Shrubs. All required shrub plantings shall form a visual screen and be a minimum of four (4) feet in height within two (2) years after planting. 6. Wall or fence. A wall or fence used within the buffer to accomplish a reduced buffer width option shall be six (6) feet in height and shall consist of one or a combination of the following materials: brick, textured concrete masonry units, stucco block, cementitious board, or other similar material approved by the director of planning. (A retaining wall shall be considered a wall for the purposes of this subsection). 7. Existing vegetation. Existing vegetation which meets or exceeds the quantity, spacing, and height standards of this section may be used to satisfy the requirements of this subsection. Supplemental native shrubs may be required, however, if it can be reasonably determined that after two (2) years, the existing vegetation will not provide the visual screen required by this section. f. Development within required buffers. 1. General. The required buffer shall not contain any development, impervious surfaces, or site features that do not function to meet the standards of this subsection or that require removal of existing vegetation, unless otherwise allowed under this ordinance. 2. Sidewalks and trails. Sidewalks and trails may be placed in buffers provided damage to existing vegetation is minimized to the maximum extent practicable. 3. Overhead and underground utilities. Overhead and underground utility lines, if allowed by the city, are permitted in buffers, but shall minimize the impact to vegetation, to the maximum extent practicable. In cases where required landscaping material is damaged or removed due to utility activity within a required buffer, the landowner shall be responsible for replanting all damaged or removed vegetation necessary to ensure the buffer meets the standards in this subsection. 4. Damage to plantings. In the event that buffer plantings are damaged in a way that results in the loss of the buffer's intended purpose, the damage shall be repaired by the landowner.

(Ord. No. 9572, § 2, 12-17-24; Ord. No. 9751, § 38, 3-10-26)

Ask a question about Tuscaloosa law

Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.