§ 25-160 — Specific site features

Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 25-160

Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/bac7b3eb-23de-4863-af51-3dc87721fb78

Sec. 25-160. - Specific site features.

a. Off-street parking areas. Maintained average horizontal illuminance values in parking lots shall not exceed 4.0 foot candles. b. Sports or performance venues. Lighting fixtures for outdoor sports areas, athletic fields, and performance areas shall be equipped with a glare control package (e.g. louvers, shields, or similar devices) and aimed so that their beams are directed and fall within the primary playing or performance area. c. Pedestrian area lighting. 1. Except for pedestrian bollard lamps, light fixtures outside of parking lots for sidewalks, walkways, trails, and bicycle paths shall comply with the following standards: i. Provide at least 1.0 footcandles of illumination, but not exceed 2.0 footcandles; ii. Have a maximum height of fifteen (15) feet; and iii. Be placed a maximum of one hundred (100) feet apart. 2. Pedestrian bollard lamps shall be mounted no higher than four (4) feet above grade and shall not exceed nine hundred (900) lumens for any single lamp. d. Flood lights, wall packs, and flood lamps. Except for single-family dwellings, flood lights, wall packs, and flood lamps on the exterior of a building shall be fully shielded (e.g. true cut-off type bulb or light source not visible from off-site) to direct the light vertically downward and shall not exceed one thousand six hundred (1,600) lumens for any single fixture. e. Canopy. Areas under a canopy shall be designed so as not to create glare off-site. Acceptable methods to address this include one or both of the following: 1. A recessed fixture incorporating a lens cover that is either recessed or flush with the bottom surface (ceiling) of the canopy that provides a full cutoff or fully-shielded light distribution; or 2. A surface mounted fixture incorporating a flat glass that provides a full cutoff or fully-shielded light distribution. f. Decorative and landscape lighting. Outdoor light fixtures used for decorative effects shall comply with the following standards: 1. Decorative lighting intended to enhance the appearance of a building and/or landscaping shall cast all light downward (rather than upward) against the building surface or onto a landscape feature. 2. Decorative lighting fixtures shall not exceed one thousand six hundred (1,600) lumens for any single fixture. g. Rope lighting. The following standards apply to rope lighting: 1. Rope lighting shall not be used around architectural building features such as windows. 2. Each light along the rope shall not emit more than fifty (50) lumens per bulb.

(Ord. No. 9572, § 2, 12-17-24)

Ask a question about Tuscaloosa law

Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.