§ 25-166 — Multifamily development
Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 25-166
Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/2b68dc62-1f68-43be-bf1b-d981ae33e191
Sec. 25-166. - Multifamily development.
a. Purpose and intent. The purpose and intent of these multifamily form and design standards are to: 1. Establish a minimum level of development quality for townhouse, triplex, quadplex, and multifamily residential development; 2. Promote greater compatibility between townhouse, triplex, quadplex, and multifamily residential development and other allowable uses; and 3. Provide landowners, developers, architects, builders, business owners, and others with a clear and equitable set of parameters for developing land. b. Applicability. 1. Except as otherwise provided in subsection 2. below, the multifamily form and design standards in this division shall apply to: i. All new townhouse, U-rowhouse, triplex, U-triplex, quadplex, multifamily, and multifamily student development; and ii. Any expansion of an existing townhouse, U-rowhouse, triplex, U-triplex, quadplex, multifamily, or multifamily student building, unless expressly stated otherwise in the specific multifamily form and design standards below, if the expansion increases the building's gross floor area by fifty (50) per cent or more. 2. The following are exempt from the multifamily form and design standards in this division: i. Development in the institutional university (IU) district; and ii. Dwellings located in the same building as and above a nonresidential principal use. c. Timing of review. Review for compliance with the standards of this division shall occur during review of a development application for a planned development (section 25-37), a conditional use permit (section 25-38), a special exception use permit (section 25-39), a land development permit (section 21-218), or building permit (chapter 6, article II), as appropriate. d. Site access. Development with fifty (50) or more dwelling units shall not have direct vehicular access along a local street serving existing single-family detached dwellings, unless no other point of access is available. e. Off-street parking. 1. No more than fifty (50) per cent of off-street surface parking may be located between a building and the street it faces unless the parking bays are screened from view from the street by another building. 2. Freestanding garages or carports visible from public streets outside the development shall be located to the side or rear of the principal dwelling and shall either (i) be oriented perpendicular to the street; or (ii) include wall offset and design features on the street-facing façade in accordance with the standards that apply to the principal dwelling (see figure VI-10: detached garage location and orientation). The exterior materials, design features, and roof form of a detached garage or carport shall be the same as those of the principal dwelling. Figure VI-10: Detached Garage Location and Orientation [image omitted; see the official code] f. Building orientation and configuration. 1. The primary entrance and architectural front of individual buildings within a multi-building development shall be oriented towards the following (listed in priority order) and not toward off-street parking lots, garages, or carports: i. Perimeter streets; ii. Primary internal streets; iii. Open space areas; or iv. Secondary internal streets. 2. Buildings shall be oriented so that architectural fronts of buildings across the street from each other face each other, so as to avoid the front façade of one building facing a side or rear façade of another building. g. Maximum length of structures. No single row of townhouse units shall exceed three hundred (300) feet in length. h. Building façades. 1. Materials and fenestration. i. Exterior building walls shall be wood clapboard, cementitious fiber board, wood shingle, wood drop siding, primed board, wood board and batten, brick, stone, stucco, vinyl, or similar material. ii. A minimum of twenty (20) per cent of the street facing façade area shall consist of windows or doorways. 2. Offsets. Building façades greater than fifty (50) feet in width that face a street shall incorporate wall offsets, in the form of projections or recesses in the façade plane at least two (2) feet in depth, spaced no more than fifty (50) feet apart (see figure VI-11: façade offsets and design features). Figure VI-11: Façade Offsets and Design Features [image omitted; see the official code] 3. Design features. Front façades shall provide a minimum of three (3) of the following design features for each residential unit fronting onto a public street (see figure VI-11: façade offsets and design features): i. One or more dormer windows or cupolas; ii. A recessed entrance; iii. A covered porch; iv. Pillars, posts, or columns next to the doorway; v. One or more bay windows projecting at least twelve (12) inches from the façade plane; vi. Eaves projecting at least six (6) inches from the façade plane; vii. Raised corniced parapets over the entrance door; viii. Multiple windows with a minimum four-inch-wide trim; ix. Integrated planters that incorporate landscaped areas or places for sitting; or x. Roof form and line changes consistent with the façade offsets. i. Roofs. 1. Sloped roofs on buildings over one hundred (100) feet in length shall include two (2) or more different sloping roof planes, each with a minimum pitch between 4:12 and 12:12. 2. Flat roofs shall be concealed by parapet walls that extend at least three (3) feet above the roof level and have three-dimensional cornice treatments that project at least eight (8) inches outward from the parapet façade plane. 3. Alternative roof forms or pitches may be allowed for small roof sections over porches, entryways, or similar features. 4. All roof-based mechanical equipment, as well as vents, pipes, antennas, satellite dishes, and other roof penetrations (except chimneys), shall be located on the rear elevations or otherwise be configured and screened (if necessary) to have a minimal visual impact as seen from the street. j. Utilities and service areas. 1. Utilities shall be underground, except where significant practical difficulties dictate otherwise. Any incremental cost of installing utilities underground shall be borne as agreed between the customer and the utility. 2. All ground-level mechanical equipment, meters, vault boxes, electrical boxes, and other similar equipment shall be located outside of the front yard and screened so as not to be visible from all rights-of-way and open space set asides. 3. All service areas, including areas for trash collection and recycling collection, shall be screened from view from all rights-of-way and open space.
(Ord. No. 9572, § 2, 12-17-24)
Ask a question about Tuscaloosa law
Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.