§ 25-69 — Mixed residential university
Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 25-69
Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/4334267f-fb0c-470a-8b53-82a3367e5656
Sec. 25-69. - Mixed residential university.
a. Purpose. The purpose of the mixed residential university (MRU) district is to provide lands for primarily single-family detached, duplex, and triplex residential development around the University of Alabama campus. The district is intended to support a medium-density residential environment and incorporate limited context-sensitive neighborhood-oriented community and educational activities. b. Use standards. Allowed uses and use-specific standards for principal, accessory, and temporary uses are established in article V, use regulations. In addition, the following standards apply to U-dwellings, as defined in section 6-109 of this Code: i. U-dwellings shall be constructed in accordance with section 6-109 of this Code. ii. When all permitted work is completed on an eligible U-dwelling development, as defined in subsection iii. below, and the U-dwelling has passed all final site, building, and zoning inspections and has been issued a final certificate of occupancy by the chief building official, the property may be certified to allow up to five (5) unrelated persons to live in a single dwelling unit. iii. Eligible U-dwelling development in the MRU district which may be certified in accordance with subsection ii. above, shall include the following: (a) New construction of a permitted U-dwelling allowed in the base zoning district that complies with the requirements of this ordinance and all other applicable city, county, state, and federal regulations; or (b) Redevelopment or conversion of an existing building and site to a U-dwelling in order to fully comply with the requirements of this ordinance and all other applicable city, county, state, and federal regulations. c. Intensity and dimensional standards. All development in the MRU district shall comply with the standards in table IV-25: MRU intensity and dimensional standards. Table IV-25: MRU Intensity and Dimensional Standards Standard [1] | Single-family detached | All other uses Density (max) | 200 bedrooms per acre, not to exceed 200 bedrooms in any one development in common ownership | 200 bedrooms per acre, not to exceed 200 bedrooms in any one development in common ownership Lot area (min) | None | None Lot width (min) | None | None [3] A | Front setback (min) | 15 ft [2] | 15 ft [2] B | Side setback (min) | 5 ft; 14 ft combined both sides | 7 ft [3] C | Rear setback (min) | 10 ft | 10 ft D | Building height (max) | 37 ft | 37 ft Notes: [1] max = maximum; min = minimum; du = dwelling units; ft = feet; sf = square feet [2] For corner lots, the minimum front setback abutting the side street shall be five feet. The minimum front setback may be decreased to the average alignment of existing buildings within 100 feet on either side of subject building and within the same block if such alignment is less than 10 feet. For single-family detached and townhouse dwellings, a street-facing garage shall be set back at least 20 feet from the front lot line. [3] There is no minimum side setback for townhouses, except a minimum side setback of seven feet is required at each end of a row of townhouses. No townhouse unit shall be less than one-third as wide as it is deep. [image omitted; see the official code] d. Site design standards. 1. Neighborhood compatibility. Development, other than a detached single-family dwelling, that abuts the historic buffer (HB) overlay district, an historic district, or an existing single-family detached house used for residential purposes in a residential zone district, shall comply with the following standards: i. No building shall extend into a forty-five (45) degree angular plane projecting over the property, measured from a height of thirty-five (35) feet at the side interior or rear setback line. Where a building roof is stepped back to comply with this requirement, rooftop living space is prohibited. See figure IV-1: rooftop living space restrictions. Figure IV-1: Rooftop Living Space Restrictions [image omitted; see the official code] ii. A fence or wall having a minimum height of six (6) feet shall be constructed along the property line shared with the abutting property. The finished side of the fence shall face out (see subsection 6., fences and walls, below). 2. Parking. i. Minimum parking required. (a) A minimum of one parking space per bedroom is required. All parking spaces used to comply with this minimum parking standard shall be off-street parking spaces, except as otherwise provided in this section. (b) On property located south of University Boulevard, north of Paul W. Bryant Drive, east of Gene Stallings Avenue, and west of Hackberry Lane, on-street parking spaces that comply with the following standards may be used to comply with the minimum parking standard in subsection (a) above: (1) The on-street space is located on a public right-of-way immediately abutting the subject property; (2) The on-street space is located on an "Avenue," not a "Street;" (3) No more than fifty (50) per cent of the on-street parking located in the areas specified in subsections (1) and (2) above is counted towards the minimum parking requirements for a development; (4) The number of on-street parking spaces used does not exceed twenty (20) per cent of the total number of required parking spaces; and (5) Curb stops are installed so that sidewalks are not affected. (c) Along Convent Street, Oak Avenue, and 14th Avenue properties adjacent to the historic districts, the on-street parking spaces immediately abutting the subject property may be used to comply with the minimum parking standard in subsection (a) above. (d) On-street parking spaces may be used to comply with the minimum parking standard in subsection (a) above, for small redevelopments in accordance with subsection (f), small redevelopment standards below. ii. Location. Parking is prohibited between the front façade of the structure and the front property line. On corner lots, the parking may encroach past the front façade along the side street, but the parking must be screened from the public right-of-way by a wall that is at least forty-two (42) inches in height and constructed of the same materials as the principal building(s). iii. Large parking lots. Open, surface parking lots containing fifty (50) or more spaces shall be divided into smaller areas separated by: (1) Landscaped areas at least ten (10) feet wide that comply with subsection 4. below; or (2) A building or a group of buildings. At least ten (10) per cent of the total surface area of each such parking lot shall be used for landscaping that is distributed and designed in accordance with an overall landscaping plan. See figure IV-2: large parking lot landscaping in MRU district. Figure IV-2: Large Parking Lot Landscaping in MRU District [image omitted; see the official code] iv. Parking structures. (a) Parking structures, if provided, shall be architecturally integrated or designed with an architectural theme similar to that of the principal building(s). (b) Vehicles shall be screened from view with a metal or architectural panel such as galvanized welded wire steel/mesh panels, an aluminum louver system, or similar treatments. The following materials, as well as materials which the director of planning determines to be visually similar to the listed materials, are prohibited: (1) Chain link (including coated chain link); (2) Vinyl or other fabrics; and (3) Window screen material. v. Mechanical lifts. The use of mechanical lifts for parking is prohibited. vi. Bicycle parking. Bicycle parking shall be provided in accordance with section 25-126, bicycle parking standards, and the following standards: (a) In each new development or redevelopment, a minimum of one bicycle parking space per unit shall be provided for developments with four (4) and five (5) bedrooms per unit. In a new development or redevelopment featuring units containing one, two (2), or three (3) bedrooms per unit, a minimum one bicycle parking space per every five (5) bedrooms shall be provided, rounded to the next highest whole number. (b) Bicycle racks shall be installed on the exterior side or rear of a building and shall be high-quality, inverted "U"-type construction or be attached to the building. Alternative high-quality bicycle parking racks may be approved by the director of planning if they can be shown to support the bicycle at two (2) points of contact to the bicycle wheels and frame. (c) Bicycle parking spaces may be located in an internal bicycle storage room if the room is lockable and contains systems for locking to allow for at least two (2) points of contact to the bicycle wheels and frame. 3. Sidewalks. i. In order to establish safe and efficient pedestrian circulation, new development shall include sidewalks that directly connect the main entrances of buildings on the site with each other and with available access points including parking areas, streets, sidewalks, and transit stops. Where such sidewalks traverse parking areas, the sidewalk shall be clearly identifiable through changes in material or elevation. ii. New development shall install sidewalks along all street frontages as needed for pedestrian mobility or safety and as appropriate to the location. Installation of such sidewalks is not required where the director of planning determines a sidewalk is impractical or unfeasible. Each sidewalk shall have a minimum width of four (4) feet or the width of the widest existing abutting sidewalk, whichever is greater. iii. Except as otherwise provided by subsection ii. above, a landscaped strip at least five (5) feet wide shall be provided between the street and the sidewalk along all street frontages. The landscaped strip shall be grass, landscaping, or trees, and shall incorporate the provisions of the right-of-way landscape requirements in subsection 4. below. Additionally, bollards shall be provided between the street and the sidewalk at intervals of four (4) feet, except where the director of planning determines the bollards are impractical or unfeasible. Where on-street parking is provided adjacent to a development or where the director of planning determines the landscape strip to be impractical, the landscape strip can be waived or modified for a six (6) feet wide sidewalk with alternative landscaping as approved by the director of planning. 4. Landscaping. i. At least one canopy tree having a minimum three-inch base caliper shall be planted or preserved in the required rear yard. The tree may be an existing tree on the site that is preserved or it may be planted. Every parking space provided in accordance with subsection 2. above shall be within a sixty-foot radius of the trunk of at least one tree. All efforts should be made to retain existing healthy canopy trees. ii. Where development occurs adjacent to an existing street, one canopy tree having a minimum three-inch base caliper shall be planted or preserved in the right-of-way for every fifty (50) feet of lot width. All efforts should be made to retain existing healthy canopy trees. iii. Trees planted to comply the requirements of this section shall be installed with an irrigation bag or be watered by an irrigation system operated by the developer to ensure healthy growth. The director of planning may waive or modify this requirement if trees are determined impractical or unfeasible. The irrigation bag or system shall be maintained for a minimum of two (2) summer growing seasons. iv. Except as otherwise provided in this section, all trees required by this section shall be maintained in landscape islands. Each landscape island shall be sodded, seeded, mulched, or planted with shrubs and/or groundcover, and may incorporate low impact development best management practices, such as rain gardens and bioswales, to promote infiltration of stormwater. 5. Screening. i. All parking lots and parking spaces shall be screened in accordance with section 25-132(c), parking lot perimeter landscaping standards. ii. Solid waste containers shall be screened from view from the right-of-way and adjacent properties using similar building materials as the primary structure. iii. All mechanical equipment located on the roof of a structure shall be screened by parapet walls that exceed the height of the mechanical unit by at least one foot. All other mechanical equipment must be screened with a wall or fence. All such screens shall be constructed from the primary building material or opaque landscaping at least thirty (30) inches in height at installation and maintained at that minimum height in a healthy condition. 6. Fences and walls. i. Fences and walls shall be constructed of wood, brick, stucco, or metal. Wood fences must be of a decorative style, such as shadow box or picket. The finished side of a fence should face out. ii. Chain link, razor wire, barbed wire, and concertina wire are prohibited as fencing material. iii. In a front setback, no part of a fence shall be within ten (10) feet of the curb line. Fences are prohibited in the public right-of-way. 7. Exterior lighting. i. All light fixtures shall be designed and oriented so as to not direct glare or excessive illumination onto adjacent properties, streets, or sidewalks. ii. Flood lights, wall packs, and flood lamps must either: (i) Be aimed downward at least forty-five (45) degrees from vertical; or (ii) Use a shielded fixture so that no portion of the light bulb extends below the bottom edge of the shield. iii. The maximum height for freestanding light fixtures is twelve (12) feet. Service connections for all freestanding light fixtures must be installed underground. iv. All surface parking areas shall be illuminated using light fixtures so that lighting is consistent across the parking area. Freestanding light poles may be located within required landscaped areas in surface parking areas. v. All structured parking shall be illuminated using light fixtures so that lighting is consistent across all public areas in the structure and no areas are dark or dim. 8. Mechanical equipment and utilities. i. Mechanical equipment associated with residential uses, such as HVAC units and security lighting, may encroach into a required rear or side setback, provided that such extension is at least two (2) feet from the vertical plane of any lot line. ii. All existing and proposed utilities including communication, cable, electric, and the like, shall be installed underground except where such utilities are not visible from any right-of-way. The zoning officer may provide an exception for poles that support only high voltage wires, switches, and transformers. 9. Accessory structures. Accessory structures on any lot used primarily for residential purposes shall comply with the following standards: i. Accessory structures are prohibited in front yards. ii. Accessory structures may be located within a side yard provided they are not located between the principal building and a street, and set back at least five (5) feet from all lot lines. iii. Accessory structures may be located within rear yards, provided they are set back at least five (5) feet from all lot lines and that no more than thirty (30) per cent of any rear yard is covered by accessory structures. iv. Accessory structures shall not be occupied at any time as a dwelling. v. No single accessory structure shall exceed six hundred (600) square feet or forty (40) per cent of the principal building's building floor area, whichever is greater. e. Building design standards. 1. Entrances. Operable, street-facing entrances are required on each building façade that fronts a public street. 2. Ground floor elevation. The ground floor elevation of each building shall be at least twenty-four (24) inches and shall not exceed thirty (30) inches. For purposes of this requirement, ground floor elevation is measured from the top of the sidewalk or the mean level of the finished grade abutting the building to the top of the finished ground floor. 3. Variation among adjacent buildings. To avoid uniform styles and provide visual interest, adjacent buildings shall be constructed with variations in materials, roof form, window patterns, elements, and façade projections, as approved by the director of planning. 4. Façade projections. Each residential structure must include a front porch, stoop, or balcony that complies with the standards in this section on each building façade that fronts a public street. i. Front porch. (a) A front porch must be at least six (6) feet deep, not including any steps providing access to the porch. (b) A front porch must have an unbroken width of at least fifty (50) per cent of the width of the building façade from which it projects, not including any steps providing access to the porch. (1) If one set of access stairs is required, those stairs shall not be located along the front façade of the building. (2) If two sets of access stairs are required, one may be located on the front façade, as long as the usable porch space is not less than fifty (50) per cent of the building façade from which it projects. (c) A front porch must be roofed and may be screened, but shall not be fully enclosed. (d) A front porch may extend up to nine (9) feet, including the steps, into a required setback, provided that such extension is at least two (2) feet from the vertical plane of any lot line. ii. Stoop. (a) A stoop must be no more than six (6) feet deep and twenty-four (24) inches wide, not including any steps providing access to the stoop. (b) A stoop may be covered but shall not be fully enclosed. iii. Balcony. A balcony may be covered and/or screened, but shall not be fully enclosed. 5. Façade variation. Each ground-floor building façade facing a public street shall include at least one of the following every ten (10) feet of its width, between the ground level and a height of ten (10) feet: i. A substantial material change (paint color is not considered a substantial change); ii. A window or door; iii. A stoop or balcony; or iv. A column, pilaster, or other articulation greater than twelve (12) inches in depth. 6. Building materials allowed. i. Primary materials. Primary material changes shall occur only at inside corners. The following materials are required for not less than seventy-five (75) per cent of the building wall surface area on each façade: (a) Brick and tile masonry; (b) Natural stone (or synthetic equivalent), such as limestone, granite, and marble; (c) Wood-clapboard or shingles; (d) Glass curtain wall; (e) Cementitious siding; and (f) Stucco (cementitious finish). ii. Accent materials. The following materials may make up twenty-five (25) per cent of the building wall surface area on each façade: (a) Pre-cast masonry (for trim and cornice elements only); (b) External insulation finishing system—EIFS (for trim and cornice elements only); (c) Gypsum reinforced fiber concrete—GFRC (for trim elements only); (d) Metal (for beams, lintels, trim elements, and ornamentation); (e) Split-faced block (for piers, foundation walls and chimneys only); (f) Glass block; (g) Vinyl shakes or shingles; and (h) Vinyl clapboard (with a minimum thickness of 0.044 inches). iii. Alternative materials. Alternative building materials not listed in subsections i. or ii. above may be approved by the director of planning if it is determined the alternative building materials are equivalent or better than the listed materials. The use of regionally-available materials is preferred. iv. Parking structure screening materials. Where screening of parking areas within a structure is required, it shall use a metal or architectural panel, such as galvanized welded wire steel/mesh panels or an aluminum louver system. The following materials, and any material the director of planning determines closely mimics any of the following materials, shall not be used to screen parking areas: (a) Chain link (including coated chain link); (b) Vinyl or other fabrics; and (c) Window screen material. 7. Elevated structures. i. Elevated structures are prohibited in the MRU subdistrict except as otherwise provided in subsection f., small redevelopment standards, below. ii. All elevated structures with at-grade parking areas located beneath the building shall include exterior screening walls to conceal the parking lot from view from the public right-of-way, not including alleys. Screening walls shall be at least four (4) feet tall and shall be constructed of same materials as the principal building. A minimum landscaping strip that is at least three (3) feet wide shall be provided between the screening wall and all adjacent rights-of-way. The landscaping strip shall be planted with shrubbery having a minimum height of thirty (30) inches at installation and capable of forming a continuous evergreen hedge having a minimum height of thirty-six (36) inches. f. Small redevelopment standards. 1. The following standards apply to development on a lot of 0.25 acres or less that will result in density of one-third (⅓) or less of the density allowed by this section: i. Up to one on-street parking space immediately abutting the property may count toward the minimum parking required by section 25-69(d)(2)(i), minimum parking required. ii. Elevated structures are allowed and may include living space that overhangs the rear of the structure, as long as the overhang is less than fifty (50) per cent of the depth of the main footprint and requires no posts for support. 2. The following standards apply to development on a lot of more than 0.25 acres and less than 0.50 acres that will result in density of one-third (⅓) or less of the density allowed by this section: i. Up to two (2) on-street parking spaces immediately abutting the property may count toward the minimum parking required by section 25-69(d)(2)(i), minimum parking required. ii. Elevated structures are allowed and may include living space that overhangs the rear of the structure, as long as the overhang is less than fifty (50) per cent of the depth of the main footprint and requires no posts for support. 3. For development on a lot 0.50 acres in size or larger that will result in density of one hundred (100) or fewer bedrooms per acre, the minimum parking required by section 25-69(d)(2)(i), minimum parking required, may be reduced by ten (10) per cent, rounded down to the nearest whole number. g. References to other standards. Development in the MRU district shall comply with all applicable standards of this zoning ordinance and the subdivision regulations, except as otherwise provided in this section, including but not limited to the standards referenced in table IV-26: cross-references to other standards. Table IV-26: Cross-References to Other Standards Section | Standard Article VI, Division 1 | Mobility and Connectivity Standards Article VI, Division 2 | Off-Street Parking, Bicycle Parking, and Loading Standards Article VI, Division 3 | Landscape and Buffer Standards Article VI, Division 5 | Fence and Wall Standards Article VI, Division 6 | Exterior Lighting Standards Article VI, Division 8 | Form and Design Standards Article VI, Division 9 | Green Building Incentives Article VI, Division 10 | Signs and Billboards Subdivision Regulations
(Ord. No. 9572, § 2, 12-17-24; Ord. No. 9670, §§ 7, 8, 8-19-25)
Ask a question about Tuscaloosa law
Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
