§ 6-109 — Amendments to code
Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 6-109
Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/4ca6806d-5938-4393-97a9-c853552af4cc
Sec. 6-109. - Amendments to code.
(a) Appendices adopted. Appendices AE, AJ, AM, AQ and AU of the 2021 International Residential Code are adopted and appendices AA, AB, AC, AD, AF, AG, AH, AI, AK, AL, AN, AO, AP, AR, AS, AT, AV and AW are deleted. (b) Section (a)(1) General Requirements is amended to add the following. "Ranges, ovens, stove tops, dryers, water heaters and AC/Heating units will not be required to provide dual services (gas piping and electric circuit) for where placement of appliances unless manufacturer's instructions requires it." (c) Section R102.7.1 is amended to add the following subsection: "R102.7.1.1. Construction requirements for existing residential detached one and two-family dwellings and townhouses not more than three stories above grade plane in height with separate means of egress and their accessory structures shall comply with adopted International Residential Code. Exception to R102.7.1: Change of occupancy classification." (d) Section R302.5.1 is amended to read as the follows: "R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and the residence shall be equipped with solid wood doors not less than 1 3/8" inches in thickness, solid or honeycomb core steel doors not less than 1 3/8" in thick, or 20-minute fire-rated doors." (e) Section R302.13 is amended to read as the follows: "R302.13 Fire protection of floors. Floor assemblies that are not required elsewhere in this code to be fire-resistance rated, shall be provided with a ½-inch (12.7 mm) gypsum wall-board membrane, 5/8-inch (16 mm) wood structural panel membrane, or equivalent on the underside of the floor framing member. Penetrations or openings for ducts, vents, electrical outlets, lighting, devices, luminaires, wires, speakers, drainage, piping and similar openings or penetrations shall be permitted. For crawl spaces or basements, fire rated materials shall only be required to extend 30" beyond the fuel-fire equipment directly above the equipment and the building official shall have the discretion to determine if a greater requirement is needed. Exceptions: to R302.13. 1. Floor assemblies located directly over a space protected by an automatic sprinkler system in accordance with Section P2904, NFPA 13D, or other approved equivalent sprinkler system. 2. Floor assemblies located directly over a crawl space not intended for storage or fuel-fired appliances or where any fuel-fired appliances are located under a crawl space less than 66" inches from the top of crawl space to the grade. 3. Portions of floor assemblies shall be permitted to be unprotected where complying with the following: 3.1. The aggregate area of the unprotected portions does not exceed 80 square feet (7.4 m 2) per story 3.2. Fireblocking in accordance with Section R302.11.1 is installed along the perimeter of the unprotected portion to separate the unprotected portion from the remainder of the floor assembly. 4. Wood floor assemblies using dimension lumber or structural composite lumber equal to or greater than 2-inch by 10-inch (50.8 mm by 254 mm) nominal dimension, or other approved floor assemblies demonstrating equivalent fire performance." (f) Table R602.3(1) line #6 Fastening Schedule is amended to add the following to spacing and location: "Rafters and trusses attachment to the plate shall be fastened with a screw with an uplift capacity of 600 lbs. when tested accordance with ASTM-D1761 or other approved high wind connectors (ESR-2613)." (g) Section R905.2.8.5 Drip Edge is amended to add the following subsection: "R905.2.8.5 (1) Wood shingle strips shall be permitted. The underlayment (or ice barrier where used) and asphalt shingles shall extend over the shingle strip by one-quarter inch (1/4")." (h) Chapter 11 Energy Efficiency is hereby deleted. (i) Any sections referencing the 2021 International Energy Conservation Code for requirements, is amended to replace the reference to the International Energy Conservation Code with the State of Alabama Energy Code where it may apply for requirements. (j) Section R403.1 is amended to add the following: "Plain concrete footings supporting walls shall be provided with not less than two continuous longitudinal reinforcing bars or other approved methods. Reinforcing bars shall not be smaller than #4. Continuity of reinforcing bars shall be provided at corners and intersections." (k) Sections P2801.4, M1305.1.2 and G2406.1 are amended to add the following: "Equipment such as, but not limited to, water heaters and mechanical equipment, located in attic spaces or other similar places shall be provided with a fixed or pull down stairway for servicing." (l) Section P2903.10 is amended to add the following: "Shutoff valves shall not be required to be installed on the water supply pipe to each sill cock." (m) Section P2903.9.1 is amended to add the following: "The provision for drainage such as a bleed orifice or installation of a separate drain valve shall not be required." (n) Section P2905.3 Hot Water Supply to Fixtures is hereby deleted. (o) Section M1503.6 is amended to read as follows: "Section M1503.6 Where one or more gas, liquid or solid fuel-burning appliance that is neither direct-vent nor uses mechanical draft venting system is located within a dwelling unit's air barrier each exhaust system capable of exhausting more than 400 cubic feet per minute (0.19 m 3 /s) shall be mechanically or naturally provided with makeup air at a rate approximately equal to the exhaust air rate in excess of 400 cubic feet per minute. Such makeup air systems shall be equipped with not less than one damper. Each damper shall be a gravity damper or an electrically operated damper that automatically opens when the exhaust system operates. Dampers shall be accessible for inspection, service, repair and replacement without removing permanent construction or any other ducts not connected to the damper being inspected, serviced, repaired or replaced. Exceptions to M1503.6: Makeup air openings are not required for kitchen exhaust systems capable of exhausting not greater than 600 cubic feet per minute (0.28 m 3 /s) provided that one of the following conditions is met: 1. Where the floor area within the air barrier of a dwelling unit is at least 1500 square feet, and where natural draft or mechanical draft space- or water-heating appliances are not located within the air barrier. 2. Where the floor area within the air barrier of a dwelling unit is at least 3000 square feet, and where natural draft space- or water-heating appliances are not located within the air barrier. 3. Where all appliances in the house are sealed combustion, power-vent, unvented, or electric." (p) M1506.1.1 is added to read as follows: "M1506.1.1 Duct Construction: Add subsection M1506.1.1 For kitchen exhaust hoods, the damper will be installed in the duct before the mechanical final inspection. The Kitchen exhaust hood will not be required to be installed at the time of the final inspection." (q) Section E3901.4.2 is hereby amended to read as follows: "E3901.4.2 Island Countertop and Peninsular Countertop Spaces. At least one receptacle outlet shall be installed at each island countertop space with a long dimension of 24 inches (610 mm) or greater and a short dimension of 12 inches (305 mm) or greater. At least one receptacle outlet shall be installed at each peninsular countertop space with a long dimension of 24 inches (610 mm) or greater and a short dimension of 12 inches (305 mm) or greater. A peninsular countertop is measured from the connecting edge." (r) Section E3902.19 is hereby added as follows: "Section E3902.19—Exception. Effective enforcement date for 250-volt receptacles with ground-fault and arc-fault circuit-interrupter protection related to ranges, ovens, stove tops, dryers, water heaters and AC/Heating appliances required for dwellings shall be June 1 st , 2023." (s) Section E3606.5 Surge Protection is hereby deleted. (t) Electrical requirements for one- and two-family dwellings shall be constructed under the International Residential Code, 2021 Edition. When in conflict, the adopted National Electric Code (NEC), 2020 Edition, known as the "Tuscaloosa Electric Code" shall control. (u) Section E3902.6 is amended to add subsection E3902.6.1 as follows: "Subsection E3902.6.1 Receptacles for refrigerators and/or freezers or similar appliances will not be required to have a ground-fault or arc fault circuit-interrupter protection when branch circuit is dedicated and single receptacle is provided." (v) Section UA U-Dwellings is hereby added as follows: "Section UA, U-Dwellings. Section UA202 Definitions NFPA—National Fire Protection Association. U-Dwelling. Residential dwelling units permitted within certain residential zones with no more than (3) three stories, built for the sole purpose of renting, or any form of leasing (joint, multiple, single) in whole or bedroom(s)with shared common living spaces within the dwelling unit(s) such as; den, kitchen and dining area, providing complete independent living facilities with permanent provisions for living, sleeping, eating, cooking and sanitation, for one to five living together, related or un-related persons, such as; college students living off campus, non-transient construction workers, non-transient professionals, or non-transient temporary housing, but not inclusive. Dwelling units may utilize sleeping units with or without attached private bathrooms. U-Single Dwelling. A U-Dwelling structure constructed as a single dwelling unit. U-Row House. A U-dwelling structure constructed in a group of three to four U-Dwellings attached to each other by any adjoining walls. Each dwelling unit is separated vertically from the foundation to the roof with fire separation and each unit has at least two sides open. U-Row houses are constructed on one lot. U-Duplex. A U-dwelling structure constructed with two dwelling units with horizontal or vertical fire separation. U-Triplex. A U-dwelling structure constructed with three dwelling Units with horizontal and/or vertical fire separation. SECTION UA301 U-DWELLING GENERAL REQUIREMENTS. UA301.1 Code Applicability. U-Dwellings shall comply with the Tuscaloosa Residential Code and this section. Mixed use U-Dwellings shall comply with the Tuscaloosa Building Code. UA301.2 Submittal Documents. Construction documents shall be prepared by a registered design professional where required by state law, municipal ordinance or the Building Official. UA301.2.1 Required documents. The following design documents and/or plans shall be required to obtain a permit for U-Dwellings; Architectural including floor plan, plot plan and elevations; Structural; Mechanical; Electrical; Plumbing; Energy and Fire Protection systems. Exception: in lieu of Structural, Mechanical, Electrical, Plumbing, Fire Protection Systems and Energy design, installations of these systems can be installed accordance with the prescriptive code of the Tuscaloosa Residential Code with exception that all buildings be designed with the latest edition of the International Residential Code tables for wood values in ceiling, floor, rafter, joist, girder and wall construction. UA301.3 Sprinkler Systems: Sprinkler systems are required in U-Dwellings. A stand-alone sprinkler system shall be separate and independent from the water distribution system after the user side of the meter. A backflow preventer shall be required between the sprinkler system and domestic water system. No multipurpose fire sprinkler systems are allowed. The design and installation shall be in accordance with NFPA 13D or Section P2904 of the 2015 International Residential Code, which shall be considered equivalent to NFPA 13D. Design Shop drawing for sprinkler systems shall be submitted to the Fire Marshal's office for approval before the installation of the sprinkler system(s). Shop drawings shall include hydraulic calculations. UA301.4 Roof Projections, Eaves, Cornices & Soffits: Shall be fire block and protected (1) one-hour rated within (3) three feet perpendicular from assumed property line between dwelling units or a rated extended parapet wall from grade shall separate between dwelling units. UA301.5 Accessibility Requirements: Any U-Dwelling structure with four or more dwelling units shall comply with the accessibility requirements in the Tuscaloosa Building Code. UA301.6 Authority Provision: The Building Official and/or Fire Marshal shall have the authority to impose or require additional safety construction methods, materials, or solutions based upon the review of a U-Dwelling structure where there is a concern of life and fire safety. UA302. U-Single Dwelling Structure. UA302.1 Sleeping Rooms. A U-Single structure shall not exceed Five (5) sleeping areas (bedrooms). UA303. U-Duplex Dwelling Structure UA303.1 Sleeping Rooms. A U-Duplex structure shall not exceed Ten (10) sleeping areas (bedrooms). UA304. U-Triplex Dwelling Structure. (Two-Family Dwelling construction methods from the Tuscaloosa Residential Code will apply to U-Triplex Dwelling Units; Except as set out in this subsection). UA304.1 Egress. Shall require two remote means of egress equal to 1/3 the diagonal of the each unit. Egresses will be designed for all occupants. Egresses shall be from common areas accessible by all occupants. An exit egress shall not pass through a room that can be locked or to prevent egress, other sleeping areas, toilet rooms or bathrooms, storage rooms, garages, closets or spaces used for similar purposes. Means of egress shall provide a clear path back to a public way. Exception: If a 13R sprinkler system is installed; the above egress requirement may comply with the Tuscaloosa Building Code. UA304.2 Interior Stairways. Interior Stairways or shafts used for access to units to ground floor shall be rated (1) one hour separating the interior of the building. Any doors in stairway or shaft shall be rated not less than 20 minutes. UA304.3 Sleeping Rooms. A U-Triplex structure shall not exceed Twelve (12) sleeping areas (bedrooms). UA304.4 Manual Fire Alarm System. A manual Fire Alarm system shall be required. Audible alarm notification appliances shall be provided and emit a distinctive sound that is not to be used for any purpose other than that of a fire alarm. The Fire Alarm system shall be activated by a flow switch in the 13d sprinkler system and manual fire alarm boxes not more than 5 feet from each exit. A permanent sign shall be installed adjacent to each manual fire alarm box that reads: WHEN ALARMS SOUNDS-CALL FIRE DEPARTMENT. The fire alarm shall provide 75 db at pillow. UA304.5 Sprinkler System. Fire sprinkler system(s) for a U-Triplex dwelling structure shall be designed for the whole structure and based on one of the following water meter arrangements. Two method are approved for fire sprinkler protection; the "preferable" and the "acceptable" water meter arrangement. Both methods shall provide water to the domestic water system and fire sprinkler system. Water meter(s) used in conjunction with the fire sprinkler system shall be locked out by the city. UA304.5.1 Preferable Arrangement. The preferable arrangement shall be separate water meters for the fire sprinkler system and domestic water. The fire sprinkler system water meter will be locked out by the city. See diagram UA304.5.1.1. [image omitted; see the official code] UA304.5.2 Acceptable Arrangement. The acceptable arrangement shall allow one water meter for the fire sprinkler system and domestic water. Domestic water shall have separate shutoff valves and shall not stop flow to sprinkler system. The water meter will be locked out by the city. See diagram UA304.5.2.1. [image omitted; see the official code] UA305 U-Row House Dwelling Units. (Townhome construction methods from the Tuscaloosa Residential Code will apply to U-Row House Dwelling Units; Except as set out in this subsection). UA305.1 Egress. Shall require two remote means of egress equal to 1/3 the diagonal of the each unit. Egresses will be designed for all occupants. Egresses shall be from common areas accessible by all occupants. An exit egress shall not pass through a room that can be locked or to prevent egress, other sleeping areas, toilet rooms or bathrooms, storage rooms, garages, closets or spaces used for similar purposes. Means of egress shall provide a clear path back to a public way. UA305.2 Sleeping Rooms. U-Row House Dwellings shall not exceed Five (5) sleeping areas (bedrooms) in any unit." UA305.3 Assumed lot lines. Assumed lot lines between units for the purpose of determining fire rated walls and the two open side requirement, will be shown on the architectural floor plans."
(Ord. No. 6559, 12-18-03; Ord. No. 7541, 5-25-10; Ord. No. 7910, 1-22-13; Ord. No. 8164, 12-16-14; Ord. No. 8186, 2-17-15; Ord. No. 8330, 1-19-16; Ord. No. 9163, 1-11-22)
Ask a question about Tuscaloosa law
Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
