§ 10.28.06 — Use of the public sewers
Code of Ordinances of the City of Conway, Arkansas (Codified through Ordinance No. O-25-35, enacted April 22, 2025. (Supp. No. 10)) · Conway Code of Ordinances § 10.28.06
Corpus is an independent public-information project, not the official City of Conway website. Stable reference: corpuslaw.us/code/04e9b16a-b129-4699-a7de-91f163cf8efe
10.28.06 - Use of the public sewers.
No person shall discharge or cause to be discharged any storm water, surface water, groundwater, roof runoff, subsurface drainage, uncontaminated cooling water, or unpolluted industrial process waters to any sanitary sewer. Storm water and all other unpolluted drainage shall be discharged to such sewers as are specifically designated as storm sewers or to a natural outlet approved by the superintendent. Industrial cooling water or unpolluted process waters may be discharged, on written approval of the City, to a storm sewer, or natural outlet. No person shall discharge or cause to be discharged any of the items as described in the City of Conway Pretreatment Ordinance to any public sewers. If any waters or wastes are discharged, which waters contain the substances or possesses the characteristics enumerated herein, and in the City of Conway Pretreatment Ordinance, and which in the judgment of the Manager of Water Systems, may have a deleterious effect upon the wastewater works, processes, equipment, or receiving waters, or which otherwise create a hazard to life or property or constitute a public nuisance, the Manager of Water Systems may: (a) Reject the wastes; (b) Require pretreatment to an acceptable condition for discharge to the public sewers; (c) Require control over the quantities and rates of discharge; and/or (d) Require payment to cover the added cost of handling and treating the wastes not covered by existing taxes or sewer charges under the provisions herein. If the Manager of Water Systems permits the pretreatment or equalization of waste flows, the design and installation of the plants and equipment shall be subject to the review and approval of the Manager of Water Systems, and subject to the requirements of all applicable codes, ordinances and laws. Where preliminary treatment or flow-equalizing facilities are provided for any waters or wastes, they shall be maintained continuously in satisfactory and effective operation as determined by the Manager of Water Systems by the owner at his expense. When required by the Manager of Water Systems, the owner of any property serviced by a building sewer carrying industrial wastes shall install a suitable control manhole together with such necessary meters and other appurtenances in the building sewer to facilitate observation, sampling, and measurement of the wastes. Such manhole, when required, shall be lockable, accessible and safely located, and shall be constructed in accordance with plans approved by the Manager of Water Systems. The manhole shall be accessible to the Water Systems Department at all times. All measurements, tests, and analyses of the characteristics of waters and wastes to which reference is made in this ordinance shall be determined in accordance with the latest edition of "Standard Methods for the Examination of Water and Wastewater," published by the American Public Health Association, shall be determined at the control manhole provided, or upon suitable samples taken at said control manholes. In the event that no special manhole has been required, the control manhole shall be considered to be the nearest downstream manhole in the public sewer to the point at which the building sewer is connected. Sampling shall be carried out by industry accepted methods to reflect the effect of constituents upon the wastewater works and to determine the existence of hazards to life, limb and property.
(Ord. No. O-10-117)
Ask a question about Conway law
Corpus searches the Conway sections it holds and shows the ones that match, with their citations. Free, no sign-in.