10.36.03 - Definitions.

The following terms and phrases, as used in this ordinance, shall have the meanings designated: Air Gap (AG): A physical separation between two (2) piping systems. ASPC: The Arkansas State Plumbing Code. AWWA: The American Water Works Association. Backflow: A hydraulic condition, caused by a difference in pressures, in which non-potable water or other fluids flow into a potable water system. Backflow Prevention Assembly (BFPA): A testable assembly installed in a water service line to prevent backflow into the potable water system. City: The City of Conway. Commercial Establishment. Is any building intended for conducting any form of business (profit or non-profit), any multifamily building, any construction site or any facility that Conway Corporation bills in its electric rate schedule as institutional or municipal. Conway Corporation: The municipal utility authorized by the City of Conway to operate the Electric, Water, Wastewater, and CATV systems serving the City of Conway. Cross-Connection Prevention Program (Program): The program developed by the Conway Corporation to prevent cross-connections to the City's Water System from non-potable water sources. Detector Double-Check Valve Assembly (DDC VA): A Double-Check Valve Assembly with a meter in parallel to detect system leaks or unauthorized use. Double-Check Valve Assembly (DCVA): A complete assembly meeting AWWA Standard C-5 10 and the requirements of the ASPC consisting of two (2) internally loaded, independently operating check valves between two (2) tightly closing resilient-seated shutoff valves, with four (4) properly placed resilient seated test cocks. Reduced-Pressure Zone Assembly (RPZA): A complete assembly meeting AWWA Standard C-51 1 and the requirements of the ASPC consisting of a hydraulically operating, mechanically independent differential relief valve located between two (2) independently operating, internally loaded check valves that are located between two (2) tightly closing resilient seated shutoff valves with four (4) properly placed resilient-seated test cocks. Water System: The City of Conway's water system serving the City of Conway, including the Water Treatment Plant (Plant) and the Water Distribution System.

(Ord. No. O-06-92, Sec. 3)

Ask a question about Conway law

Corpus searches the Conway sections it holds and shows the ones that match, with their citations. Free, no sign-in.