For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 168.10 — Provisions For Flood Hazard Reduction

Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 168.10

Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/998b0293-6d93-4d8c-8963-9fc2afe965f1

168.10 - Provisions For Flood Hazard Reduction

General Standards. The following standards apply to all developments in special flood hazard areas, regardless of the type of proposed development or the risk zone of the proposed site. (A) All new and substantial construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (B) All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; (C) All new construction or substantial improvements shall be constructed with materials resistant to flood damage; (D) All critical facilities constructed or substantially improved in special flood hazard areas (SFHA) must be constructed or modified to exceed five hundred (500) year flood protection standards or located outside the SFHA. (E) The placement or construction of all new structures must be in full compliance with the provisions of this Code. (F) For the purposes of this Code, all mixed-use structures are subject to the more stringent requirements of residential structures. (G) A substantial improvement or substantial damage to an existing structure triggers a requirement to bring the entire structure into full compliance with the provisions of this Code. The existing structure, as well as any reconstruction, rehabilitation, addition, or other improvement, must meet the standards of new construction in this Code. (H) Any improvement to an existing structure that is less than a substantial improvement requires the improvement, but not the existing structure, to be in full compliance with the provisions of this Code. (I) All manufactured homes to be placed within a special flood hazard area on a community's FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. Screw augers or expanding anchors will not satisfy the requirement of this provision. (J) The design or location of electrical, heating, ventilation, plumbing, and air conditioning equipment for new structures, or for any improvements to an existing structure, must prevent water from entering or accumulating within the components during base flood events by meeting the same freeboard or floodproofing requirements of the structure they serve. (K) The design of all new and replacement water supply systems must minimize or eliminate infiltration of floodwaters into the system during base flood events. (L) The design of all new and replacement sanitary sewage systems must minimize or eliminate infiltration of floodwaters into the system during flooding events and must prevent sewage discharge from the systems into floodwaters. (M) The placement of on-site waste disposal systems must avoid impairment to, or contamination from, the disposal system during base flood events. (N) Construction of basement foundations in any special flood hazard area is prohibited. (O) New construction and substantial improvements, with fully enclosed areas (such as garages and crawlspaces) below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are below the base flood elevation shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: (1) A minimum of two (2) openings on separate walls having a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding shall be provided. [image omitted; see the official code] (2) The bottom of all openings shall be no higher than 1 foot above grade. (3) Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (P) The placement of recreational vehicles (RV) in special flood hazard areas must either: (1) Be temporary, as demonstrated by the RV being fully licensed, being on wheels or a jacking system, attached to the site only by quick disconnect type utilities and security devices, having no permanently attached additions, and being immobile for no more than one hundred eighty (180) consecutive days; or else (2) Meet all provisions of this Code applicable to manufactured home structures. (Q) All proposals for the development of a residential subdivision, commercial business park or manufactured home park/subdivision must have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize or eliminate flood damage. (R) All proposals for the development of a residential subdivision, commercial business park or a manufactured home park/subdivision must include an adequate drainage plan to reduce exposure to flood hazards. (S) All proposals for the development of a commercial business park or a manufactured home park/subdivision must include an adequate evacuation plan for the escape of citizens from affected nonresidential structures during flooding events. (T) Standards for Subdivisions: Applications for preliminary, final, and/or concurrent plat approval shall: (1) Identify the special flood hazards areas, including delineation of floodways and the elevation of the base flood. (2) All final plats shall provide the elevation of proposed structure(s) and pad(s). If the site is filled above the base flood, the final pad elevation shall be verified by a registered professional engineer, or surveyor, and provided to the Floodplain Administrator. [image omitted; see the official code] (3) To the extent practicable, lot boundaries shall be made to coincide with natural and pre-existing man-made drainage ways within subdivisions to avoid the creation of lots that can be built upon in only by altering such drainage ways. (See illustration: Figure 3.) Any lot platted so that a portion of the lot lies in a special flood hazard area shall contain a minimum of 6,000 square feet of buildable area, including setbacks, outside the special flood hazard area, or if it contains less than 6,000 square feet of buildable area, it shall be platted to contain a minimum of 1 acre. Any lot platted so that the entire lot lies in a special flood hazard area shall contain a minimum of 1 acre. (See illustration: Figure 4.) [image omitted; see the official code] (4) For subdivisions partially located in special flood hazard areas, minimum lot area requirements may be waived by the director to allow the platting of lots to be clustered outside the special flood hazard area, the density permitted for the zoning district to be averaged over the entire parcel, provided a permanent conservation easement is granted to the city, a land trust, or the property owners association to ensure that the area of special flood hazard will remain undeveloped. (5) In all areas designated as a Zone A on the FIRM where a detailed study has not been completed to specify the floodway and base flood elevations, no development shall be located within the Zone A area. (a) Provided, the applicant may choose, if not required by other provisions of this chapter, to provide a detailed hydrologic and hydraulic study which delineates the floodway, one hundred (100) year floodplain boundary, and base flood elevations. At such time as a study is approved by FEMA, the applicant shall meet all requirements for areas designated with floodway, one hundred (100) year floodplain, and base flood elevations. (b) If, for some reason, the property owner believes the FIRM to be inaccurate, a letter of map amendment may be submitted to FEMA by the applicant. If the boundaries of the floodplain are approved and amended by FEMA, setbacks will be enforced pursuant to the amendment. (U) Any new construction, addition or other development may be approved in a special flood hazard area only if: (1) The applicant has provided a detailed hydrologic and hydraulic study performed by a professional engineer licensed in the state of Arkansas which delineates the floodway, 1% annual chance (100-year) floodplain boundary, and base flood elevations and demonstrates through a hydrologic and hydraulic analysis, that the development will not increase flood flows (0.0 cubic feet per second), flood heights (0.00 feet) or flood channel velocities (0.0 feet per second) on the subject property or any property upstream or downstream, and (2) The proposed development does not increase flood damage to off-site properties during the occurrence of the regulatory flood (1% annual chance/100-year) or any flood of more frequent occurrence, and (3) The proposed development provides compensatory storage for any measurable loss of flood storage capacity. (4) Provided that this shall not apply for a single accessory structure per lot placed on existing grade (no proposed fill material), without a foundation and no larger than 150 square feet, including storage sheds, playground equipment, gazebos, etc., that is not located within a regulatory floodway and constructed in compliance with the remainder of this Code. (V) Any structure, including but not limited to new structures, additions and substantial improvement, constructed on property fully or partially within the special flood hazard area (SFHA) shall meet the elevation or floodproofing requirements within §168.11 as applicable, even if the structure itself is located outside the SFHA.

(Ord. No. 5141, 5-6-08; Ord. No. 6446, §10(Exh. E), 6-15-21; Ord. No. 6539, §§ 9—11, 3-1-22)

Ask a question about Fayetteville law

Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.