§ 175.04 — Minimum Manufactured Home Park Design Standards
Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 175.04
Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/69272b1b-ad2d-45b4-a1e6-5878ef90a697
175.04 - Minimum Manufactured Home Park Design Standards
(A) Minimum Park Area Requirements. The minimum site for a manufactured home park development shall be 3 acres. (B) Park Site Location; Drainage. The manufactured home park shall be located on a well-drained site, and shall be located so that its drainage will not endanger any water supply. All such manufactured home parks shall be in areas free from marshes, swamps, or other potential breeding places for insects or rodents. (C) Minimum Manufactured Home Lot Requirements in a Park. The minimum manufactured home lot shall: (1) Minimum Lot Area. Contain a minimum of 4,200 square feet of area. (2) Parking. Provide for a hard surfaced off the street parking area for two (2) vehicles. The hard surface shall consist of at least a double asphaltic seal coat. (D) Manufactured Home Pad Requirements. The manufactured home pads in a manufactured home park shall be located on the manufactured home lot and designed in such a way that: (1) Separation. Manufactured homes, including any attachment thereto, shall be separated from each other at least 20 feet. (2) Exterior Boundaries. Manufactured homes shall be located at least 10 feet from any exterior boundaries of the manufactured home park adjacent to private property. (3) Public Street. Manufactured homes shall be located at least 25 feet from any public street. (E) Recreation Area. (1) Required. Recreation areas and facilities should be provided to the extent necessary to meet the anticipated needs of the tenants the park is designed to serve. In no event shall less than 8% of the gross park site area be devoted to recreational facilities. (2) Maintenance. Maintenance of recreation areas and facilities shall be the responsibility of the person to whom a manufactured home park operator's permit is issued under §175.01(A) through (E), provided, prior to the sale of any lot within a manufactured home park, the owner shall cause to be included as part of the transfer of title to said lot, a restrictive covenant in favor of the city and in favor of property owners within the park which shall require all owners to be collectively responsible, under the terms of this section, for the maintenance and upkeep of the recreation area required hereunder after 50% or more of the total area within the manufactured home park has been sold. (F) Tenant Storage Facilities. Tenant storage facilities shall be provided on each manufactured home lot, or in compounds located within a reasonable distance, generally not more than 100 feet from each manufactured home pad. Storage facilities should be designed in a manner to enhance the appearance of the development and shall be constructed of suitable weather resistant materials appropriate under the use and maintenance contemplated. A minimum of 90 cubic feet of tenant storage space shall be provided for each manufactured home pad. (G) Manufactured Home Supports and manner of Tiedown. (1) Adequate Support for Manufactured Home. The manufactured home support shall not heave, shift or settle unevenly under the weight of the manufactured home due to frost action, inadequate drainage, vibration, or other forces acting on the structure. (2) Anchors or Tiedowns. Anchors or tiedowns, such as cast-in place concrete dead men, eyelets imbedded in concrete screw augers, or arrowhead anchors shall be placed at least at each corner of the manufactured home and each device shall be able to sustain a minimum load of 4,800 pounds. Anchors or tie-down design shall be equal to or better than that recommended by the Manufactured homes Manufacturers Association. (H) Required Screening. Whenever the external boundaries of a manufactured home park abuts property in a R or R-O district or a city street or highway, there shall be provided in such park along the common boundary line a screening wall meeting the standards of Development, Chapter 166. (I) Manufactured Home Park Structure Regulations. (1) Exclusive Use. Structures placed in a manufactured home park shall be for the exclusive use of manufactured home park occupants. (2) Sanitary Facilities. Every park shall provide community sanitary facilities in a community building to be located in the park with the following emergency sanitary facilities: (a) Toilets/Sinks. For each one hundred (100) manufactured home lots, or fractional park thereof, there shall be one flush toilet and one lavatory for each sex. (b) Emergency Facilities. The building containing such emergency sanitary facilities shall be accessible to all manufactured homes. (3) Structures Prohibited in Manufactured Home Parks. Temporary or permanent tents or tent like structures shall not be permitted in a manufactured home park and the location of such a structure is prohibited in manufactured home parks. (J) Water Supply/Potable Water. An accessible, adequate, safe, and potable water supply shall be provided for each manufactured home park, capable of furnishing a minimum of 150 gallons per day for each manufactured home space. (1) Connection. Where a public supply of water is available, connection shall be made thereto and its supply shall be used exclusively. (2) Meter. Each manufactured home shall be provided with an individual water meter and each manufactured home shall be individually metered. (3) Piping. All water piping shall be constructed and maintained in accordance with state and local law; the water piping system shall not be connected with nonpotable or questionable water supplies and shall be protected against the hazards of backflow or back-siphonage. (4) Drinking Fountain. Where drinking fountains are provided for public use, they shall be of a type approved by the State Board of Health and in locations approved by the Enforcement Officer. (5) Construction. Individual water-service connections which are provided for direct use by manufactured homes shall be so constructed that they will not be damaged by the parking of such manufactured homes. (K) Electricity; Exterior Lighting. (1) Outlet Supply. An electrical outlet supplying at least 115 volts shall be provided for each manufactured home space. The installation shall comply with all applicable state and local electrical codes and ordinances. Such electrical outlets shall be grounded and weatherproof. No power supply line to the manufactured home space shall be permitted to lie on the ground or be suspended less than 10 feet above the ground. No power supply line in a manufactured home park shall be suspended less than 15 feet over any driveway. (2) Connection. The point of the electrical connection for the manufactured home should be within the area of the manufactured home pad and approximately 40 feet from the front of the stand. (3) Grounding. All exposed noncurrent-carrying metal parts of the manufactured homes and equipment shall be grounded by means of an approved grounding system. The neutral conductor shall not be used as an equipment ground for manufactured homes or other equipment. (4) Exterior Lighting. Adequate public lighting shall be provided for all streets, walkways, buildings and other facilities subject to night time use in all manufactured home parks. (L) Fuel. All piping from outside fuel storage tanks or cylinders to manufactured homes shall be rigid iron pipe or AGA or UL labeled flexible tubing, permanently installed, and securely fastened in place, in such a manner as to exclude the possibility of damage by physical contact. All fuel storage tanks or cylinders shall be securely fastened in place and shall not be located inside or beneath the manufactured home exit, and shall be located and secured in such a manner as to not be susceptible to damage by physical contact. (M) Fire Protection. (1) Fire Regulations. The manufactured home park area shall be subject to the rules and regulations of the fire prevention authority of the city. (2) Litter. Manufactured home park areas shall be kept free of litter, rubbish, and other flammable materials. (3) Fire Extinguishers. Portable fire extinguishers of a type approved by the fire prevention authority shall be kept in service buildings and shall be maintained in good operating condition. (N) Alterations and Additions. (1) Plumbing and Electrical Repairs. All plumbing and electrical alterations or repairs in the manufactured home park shall be made in accordance with applicable local regulations. (2) Permanent Additions. No permanent additions shall be built onto or become a part of any manufactured home unless they are in accordance with building permits issued by the enforcement officer and meet all setback requirements.
Ask a question about Fayetteville law
Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.