§ 27-404 — Lot dimension standards
Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 27-404
Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/07f58097-770b-427b-bcad-d560898945c1
Sec. 27-404. - Lot dimension standards.
A. Standards. Table 27-404-A lists the lot dimension standards that apply within all zoning districts. These are base standards only; other provisions within the unified development ordinance may further limit development on a site. These standards apply to all uses unless expressly exempted. Table 27-404-A. Lot Dimension Standards District | Density/Min. Lot Size | Min. Lot Width at Bldg. Line | Min. Street Frontage | Max. Lot Coverage | Setbacks | Ht. Front | Side | Street Side | Rear | Side/ Rear Adjacent to: Residential Districts Residential estate three | 3 acres | 200 ft. | 50 ft. | 10% | 50 | 25 | 50 | 25 | 35 ft. Residential estate one | 1 acre | 100 ft. | 50 ft. | 20% | 40 | 15 | 40 | 20 | 35 ft. SF Low-density | 14,000 sq. ft. | 100 ft. | 50 ft. | 30% | 30 | 10 | 30 | 10 | 35 ft. SF Med. density | 10,500 sq. ft. | 75 ft. | 50 ft. | 50% | 30 | 7.5 | 30 | 10 | 35 ft. SF Med./high-density | 6,500 sq. ft. | 60 ft. | 20 ft. | 60% | 25 | 7.5 | 25 | 10 | 35 ft. SF High-density | 5,000 sq. ft. | 50 ft. | 20 ft. | 65% | 20 | 5 | 20 | 10 | 35 ft. SF Row house and zero lot line | See section 27-411.1 SF Duplex low/med.-density | 10,500 sq. ft. | 75 ft. | 50 ft. | 50% | 30 | 7.5 | 30 | 10 | 35 ft. SF Duplex med./high-density | 6,500 sq. ft. | 60 ft. | 20 ft. | 60% | 25 | 7.5 | 25 | 10 | 35 ft. SF Duplex high-density | 5,000 sq. ft. | 50 ft. | 20 ft. | 65% | 20 | 5 | 20 | 10 | 35 ft. MF Low-density | 10 du/acre 10,500 sq. ft. | 75 ft. | 20 ft. | 60% | 30 | 7.5 | 15 | 10 | SF 30 | 35 ft. MF Med. density | 20 du/acre 6,500 sq. ft. | 60 ft. | 20 ft. | 65% | 25 | 7.5 | 15 | 10 | SF 30 | 40 ft. MF High-density | 30 du/acre 5,000 sq. ft. | 50 ft. | 20 ft. | 70% | 20 | 5 | 15 | 5 | SF 40 | 40 ft. Mixed density | See section 27-415 Residential historic | 8.7 du/acre | 50 ft. | 20 ft. | 65% | 10 | 5 | 10 | 5 | 35 ft. Residential mixed use | Determined base on site plan approval Commercial Districts Transitional | 5,000 sq. ft. | 50 ft. | 50 ft. | 65% | 20 | 5 | 20 | 10 | 35 ft. Neighborhood compatible | 7,000 sq. ft. | 50 ft. | 20 ft. | 60% | 25 | 10 | 10 | 10 | 35 ft. Commercial light | 7,000 sq. ft. | 50 ft. | 20 ft. | 60% | 25 | 10 | 10 | 10 | 35 ft. Commercial moderate | 12,000 sq. ft. | 75 ft. | N/A | 60% | 25 | 20 | 15 | 20 | SF 30 | 35 ft. Commercial heavy | 14,000 sq. ft. | 100 ft. | N/A | 75% | 25 | 20 | 15 | 20 | SF 30 | 45 ft. Commercial/ employment mixed use | Determined base on site plan approval Commercial regional | 40,000 sq. ft. | 150 ft. | N/A | 80% | 25 | 20 | 20 | 20 | SF 100 | 45 ft. Commercial downtown | N/A | N/A | N/A | 100% | N/A | N/A | N/A | N/A | N/A | N/A Industrial Districts Industrial light | 20,000 sq. ft. | 100 ft. | N/A | 75% | 25 | 10 | 15 | 10 | SF 100 | 45 ft. Industrial moderate | 20,000 sq. ft. | 100 ft. | N/A | 60% | 50 | 25 | 25 | 20 | SF 100 | 45 ft. Industrial heavy | 20,000 sq. ft. | 100 ft. | N/A | 60% | 100 | 50 | 100 | 20 | Non-I 100 | 45 ft. (1) Some building heights may be adjusted based on setback (see districts). (2) Building separation shall be determined by the current city building and fire codes. (3) See section 27-602-4D3a for additional setback requirements on multifamily projects. B. Lot area. 1. Measurement. Lot area is measured as the amount of net land area contained within the property lines of a lot or parcel, not including right-of-way for streets. 2. Lots with less than minimum width. a. A single-family or two-family house may be built on a lot that is smaller than required by the zoning district in which the lot is located, provided that the lot: 1. Is located in a residential zone that permits the intended use; 2. Is at least 35 feet wide and 3,500 square feet in area; 3. Has boundaries and dimensions that were established by record on the effective date of the unified development ordinance by a recorded plat of a subdivision; 4. Shall comply with the residential parking regulations in section 14-52. b. On any nonconforming lot that is less than 60 feet wide at the building line or 6,500 square feet in area, new structures must conform to the bulk and area requirements of the residential zone which most nearly corresponds to the minimum lot dimensions of the substandard lot. 3. Utilities. Utilities using land or an unoccupied building covering less than 1,000 square feet of site area are exempt from the minimum lot area standards. C. Setbacks. 1. Measurement. Setbacks are measured as the unobstructed and unoccupied open area between the minimum setback and the property lines of the lot on which the structure is located, except as modified by the standards of this section. Setbacks must be unobstructed from the ground to the sky except as specified in this section. 2. Along a private street, setback measurement shall start at a point 25 feet from the street centerline. 3. The following structures may encroach no more than three feet into the required setbacks if: (1) they are approved by the city building official, and (2) provided that they do not cross property lines or utility easements: a. Reserved; b. Porches, decks landings, and stairs, provided they are for single-story buildings and are not covered; c. Play equipment; d. Clothesline poles if not located in the setbacks adjacent to street right-of-way; e. Portable yard furniture; f. Reserved; g. Overhangs, coves, and cornices as defined in the currently adopted building code may be allowed, provided they do not exceed three feet. The definition of overhang specifically excludes any exterior wall of any structure regardless of its elevation above ground level; h. Mechanical units; i. Area and security lighting fixtures and supports (poles). 4. Setback averaging. Regardless of the minimum front or rear setback required by the underlying zoning district, front or rear setbacks may be adjusted to the average of the existing setbacks of the lots that are on both sides of the subject lot according to the following: a. Only the setbacks on the lots that abut each side of the subject lot on the same side of the street as the subject lot may be used. b. When one abutting lot is vacant or a corner lot, then the average is of the setback of the non-vacant lot and the zoning district minimum setback. 5. All residential lots on a cul-de-sac street that have frontage on the radius of the cul-de-sac are permitted to have a front yard setback of 20 feet. 6. Except as otherwise provided in individual zone districts and/or overlay districts, signs are to be exempt from setbacks and minimum requirements provided they are erected in compliance with the provisions of the city's sign regulations. 7. Gasoline sales are permitted under the following conditions: a. Pump islands shall be located a minimum of 20 feet from any public right-of-way. b. Island canopy overhangs shall be located at least ten feet from any public right-of-way and must have a height of at least 12 feet. Supportive posts of canopies shall be located at least 20 feet from any public right-of-way. 8. The following structures are exempt from setback regulations as specified below: a. Patios, terraces, walks, and driveways provided they are at grade, and do not have enclosed walls or a roof; b. Ramps for the purpose of meeting accessibility requirements provided they do not have enclosed walls or a roof; 1. Fences. 2. Electric vehicle charging stations. 9. Residential property platted prior to the effective date (August 12, 2009) of the UDO is permitted to use the 15-foot exterior side yard setback. This exemption does not include multifamily developments. 10. When a multifamily, commercial or industrial development abuts a platted alley and an enhanced setback is required because it is next to property zoned or developed as single-family, the setback shall be measured from the centerline of the alley. 11. When a subdivision plat identifies a setback different from the zoning district's minimum setback, the most restrictive setback dimension shall apply. D. Height. 1. Measurement. Building height is the mean vertical distance from the average ground level at the minimum front setback to the highest permanent part of the building or structure. 2. A structure may not be more than the maximum allowable feet high at the minimum setback lines, but for each additional foot of horizontal setback in excess of the minimum from all setbacks, the height may be increased by one foot. The height of a gabled end of a building shall be measured at the midpoint of the gable instead of the peak of the gable. 3. The following structures may be exempted from the height requirements in the various districts if they are not detrimental to neighboring property and are approved by the city building official: a. Chimneys; b. Vents; c. Flagpoles; d. Antennas, including dish antennas, for reception only of radio and television signals (transmitting antennas, towers, and other structures on which receiving antennas are located are not exempt from height or other setback requirements); e. Rooftop HVACR units (heating and air equipment); f. Penthouse, as defined in the building code. 4. The construction, maintenance, or establishment of any building, tree, smokestack, chimney, flagpole, wire, tower, parapet or other structure or appurtenance thereto, which can constitute a hazard or obstruction to safe air navigation, landing, or take off of aircraft near an airport, is prohibited. Regulations adopted by the Federal Aviation Agency (FAA) shall be minimum standards. No request shall be approved if it violates FAA standards.
(Code 1992, § 27-404; Ord. No. 47-10, § 2, 10-5-2010; Ord. No. 16-12, § 2, 2-21-2012; Ord. No. 29-14, § 1(att.), 6-3-2014; Ord. No. 14-15, § 1(att.), 2-3-2015; Ord. No. 64-15, § 1(att.), 10-6-2015; Ord. No. 77-17, § 1, 12-19-2017; Ord. No. 105-22, § 1, 11-1-2022; Ord. No. 117-22, § 1, 12-1-2022; Ord. No. 101-23, 12-19-2023)
Ask a question about Fort Smith law
Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.
