§ 27-603 — Access management
Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 27-603
Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/0c4a5a14-8254-4efd-a580-9b0cb365fee5
Sec. 27-603. - Access management.
27-603-1 Generally. A. The city engineering department shall administer the access management standards and regulations. B. The preliminary subdivision plat or development plan must identify the location of proposed driveways in conformance with these regulations. No additional driveways may be identified as part of the final plat process. Compliance with these provisions for infill or redevelopment will be determined on a case-by-case basis. 27-603-2 Driveway separation standards. A. Driveway access must conform to the specifications outlined in table 27-603-1A (minimum separation between driveways and street intersections) and table 27-603-1B (minimum separation between adjacent driveways). For purposes of measuring driveway separation, the separation standards apply to driveways on lots adjacent to the subject lot as well as to those on the subject lot itself. B. Offset driveways must be spaced at a sufficient distance from other driveways to allow for safe and efficient traffic flow. C. The preliminary subdivision plat and development plans must include information regarding existing driveways for adjacent and opposite sides of street properties. D. Where necessary for the safe and efficient movement of traffic, driveway access points must be limited to restricted turning movements (e.g., right turns only). E. A minimum separation between driveways and street intersections must be measured as indicated in figure 27-603-1, dimension A for driveway separation and as noted in table 27-603-1A (minimum separation between driveways and street intersections) or table 27-603-1B (minimum separation between adjacent driveways). [image omitted; see the official code] F. Driveways must be located as far as possible from intersections. G. Shared driveways are permitted and encouraged. H. Existing driveway access points must be redesigned where needed to safely control traffic flow, unless the redesign would deny the landowner reasonable access. I. Common driveways may be constructed for the joint use of adjoining properties. Documentation of the existence of common rights to driveway access (cross access agreements) is required and must be submitted either with the plat or the rezoning request. J. Directional driveways that restrict the movement of traffic to right-turn-only or left-turn-only are required where needed to provide traffic safety. K. No driveways will be permitted in areas designated as "Limits of No Access" by either the state highway and transportation department or by plat. L. Access separation between a driveway and an intersection shall be measured from the nearest edge of the driveway to the intersecting street centerline, except for freeways. M. Spacing from freeways is measured from the centerline of the nearest freeway ramp or frontage road right-of-way line (see minimum separation dimension 'A' standards) in table 27-603-1A, minimum separation between driveways and intersections). N. Separation between driveways is from the inside edge to inside edge of the driveway (see table 27-603-1B, minimum separation between adjacent driveways). Table 27-603-1A. Minimum Separation Between Driveways and Street Intersection (Dimension A in Feet) Street On Which Driveway Is To Be Located (See Dimension A) Intersecting Street | Freeway Frontage Road | Boulevard | Major Arterial | Minor Arterial | Industrial | Major Collector | Residential Collector Freeway Frontage Road* | N/A | 200 | 200 | 200 | 200 | 200 | 230 Boulevard | 250 | 250 | 170 | 170 | 170 | 150 | 150 Major Arterial | 250 | 250 | 170 | 170 | 170 | 150 | 150 Minor Arterial | 250 | 250 | 170 | 170 | 170 | 140 | 140 Industrial | 235 | 235 | 155 | 135 | 135 | 115 | 135 Major Collector | 235 | 185 | 135 | 125 | 125 | 95 | 95 Residential Collector | 230 | 185 | 130 | 120 | 120 | 95 | 95 Measured from the frontage road right-of-way. Table 27-603-1B. Minimum Separation Between Adjacent Driveways (In Feet) Residential Street | Freeway Frontage Road | Boulevard | Major Arterial | Minor Arterial | Industrial | Major Collector | Residential Collector 100 ** | 200 | 300 | 200 | 150 | 100 | 125 | 100 ** Excludes permitted uses in residential zoning districts. Adjacent driveway separation is measured from driveway inside edge to inside edge. 27-603-3 Intersection design. A. Generally. All driveways and access facilities shall be designed to meet the grade, alignment, pavement, and channelization standards and other specifications prescribed by adopted city standards. B. Two-way driveways. 1. The intersection of a two-way driveway shall intersect any arterial in a 90-degree angle. 2. The corner radius of a 90-degree driveway shall be at least ten feet. However, residential driveways on residential or collector streets shall have a minimum radius of five feet. 3. A minimum sight distance for vehicles egressing a driveway to an arterial shall be based on the 85th percentile speed of the roadway and the distance shown in table 27-603-3-A. The sight distance shall be measured as follows: a. From a point on the driveway at least 15 feet from the edge of the arterial street pavement; and b. From a height of eye of 3½ feet on the driveway to a height of object of 4½ feet on the arterial street. Table 27-603-3-A. Speed | Intersection Sight Distance Distance Desirable (feet) | Distance Minimum (feet) 15 | 145 | 80 20 | 195 | 115 25 | 240 | 155 30 | 290 | 200 35 | 335 | 250 40 | 385 | 305 45 | 430 | 360 55 | 530 | 495 60 | 575 | 570 65 | 625 | 645 C. One-way driveways. 1. One-way egress driveways shall conform to the sight distance requirements in subsection B.3 of this section, above. 2. One-way egress driveways of less than 90 degree egress may be required by the city engineer where it is determined that is in the interest of the health, safety, and general welfare of the public. 27-603-4 Access for mixed use districts. A. Residential access. 1. Access to residential lots in a mixed use district may be made from rear-access private driveways as provided below. If access is from a private driveway, the driveway shall not exceed 16 feet in width at any point between the sidewalk line and the rear of the principal building. A walkway with a minimum width of three feet shall extend from the sidewalk to the front entry. 2. Rear-access private driveways shall be paved and maintained by a homeowners' association. 3. Where rear-access private drives are used for residential access, the applicant may request an adjustment to the front yard setback of up to 20 percent decrease in size. B. Nonresidential access. Access to nonresidential lots in a mixed use district may be from a rear-access private drive or common parking areas.
(Ord. No. 70-11, § 2, 9-6-2011) (Code 1992, § 27-603)
Ask a question about Fort Smith law
Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.
