Sec. 105-54. - Local exceptions to National Electrical Code.

(a) The following rules shall govern local conditions and shall be exceptions to the National Electrical Code: (1) All commercial buildings, except those listed in the following subsection, shall be wired in conduit with conduit being defined as: a. A properly certified manufactured home being converted for use as a commercial office shall be exempt from the requirements to be wired in metal conduit when said structure shall be occupied on a temporary basis, with temporary being defined as a limited time not to exceed 12 months. Under extenuating circumstance, an appeal for extension of time can be made to the city council for approval. b. Properly certified pre-built off-site portable office buildings, not exceeding 500 square feet shall be exempt from the requirements to be wired in metal conduit, when said structure shall be occupied on a temporary basis, with temporary being defined as a limited time not to exceed 12 months. Under extenuating circumstances, an appeal for extension of time can be made to the city council for approval. c. Any Type 6 wood frame noncommercial accessory buildings to a residential use shall be exempt from the requirements to be wired in metal conduit. (2) Overhead service masts shall be rigid conduit or intermediate metallic conduit or PVC. (3) Thin wall conduit shall not be used for service entrances. (4) PVC conduit may be installed outdoors when it meets the rating required for exposure to outside elements. (5) The minimum size of aluminum wire that can be used is No. 2 stranded. (6) A master switch or breaker shall be installed on all electric services up to 400 amps. The switch or breaker shall be installed at the entrance of the electric meter and the entrance shall not be concealed. Services over 400 amps shall follow NEC. (7) No permit shall be issued for electric service exceeding 200 amps nor for any three phase service until written approval has been issued by the local utility. (8) No appliances requiring a separate circuit shall be wired without a permit. (9) In residential structures there shall be no more than ten duplex receptacles or lights per each 15 amp circuit. (10) In residential structures there shall be no more than 13 duplex receptacles or lights per each 20 amp circuit. (11) No appliances requiring a separate circuit shall be wired without a permit.

(Code 2006, § 11.20.11; Ord. No. 3008, §§ 2, 3; Ord. No. 08:093, § 5, 11-6-2008; Ord. No. 14:041, § 2, 7-1-2014)

Ask a question about Jonesboro law

Corpus searches the Jonesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.