For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 112-129 — Performance standards

Code of Ordinances of the City of Jonesboro, Arkansas (Codified through Ordinance No. 25:028, enacted September 2, 2025. (Supp. No. 16)) · Jonesboro City Code § 112-129

Corpus is an independent public-information project, not the official City of Jonesboro website. Stable reference: corpuslaw.us/code/258f2292-c8c7-405a-a78b-c5a9e2e743f6

Sec. 112-129. - Performance standards.

(a) Stormwater channel location. Generally acceptable locations of stormwater runoff channels may include but not be limited to the following: (1) In a depressed median of a double roadway, street or parkway provided the median is wide enough to permit maximum 3:1 side slopes; (2) Along the roadway, street, or parking; or (3) Located along lot lines within the rear yards of lots or parcels. Stormwater runoff channels located along front and side lot lines shall be enclosed with conduits sized in accordance with the drainage manual, except (i) industrial zoned properties located in the Craighead Technology Park; and, (ii) side lot line channels serving 100 acres or more of up stream drainage area. Channels along rear lot lines can be open ditch. In all cases, provisions (site grading, berms, dikes, swales, etc.) shall be provided for the safe containment or conveyance of the base flood along these routes. All channels shall be designed in accordance with the Drainage Design Manual. (b) Easements. Drainage easements for access maintenance, detention and conveyance of stormwater shall be provided and shown on the final plat. Easements shall be required for all drainage ways serving two or more lots or parcels and shall be designated for drainage only. Minimum required dimensions for drainage easements are included in the Drainage Manual (Figures 1 and 2; Appendix 2), but in no case shall the prescribed easements be less than that required to convey or detain the 100-year runoff. All drainage easements shall have a maintenance agreement approved before final acceptance of the improvements. No buildings or other structures shall be erected or placed in a drainage easement. Fencing of drainage easements is by permit only in accordance with section 117-329 of Chapter 117. Fencing, if permitted, must be able to pass a three-inch object without obstruction, and be gated to facilitate access to the easement for inspection and maintenance. (c) Storm sewer outfall. The storm sewer outfall shall be designed in accordance with the drainage manual so as to provide adequate protection against downstream erosion and scouring. (d) Lot lines. Whenever the plans call for the passage or storage of floodwater, surface runoff, or stormwater along lot lines, grading of all such lots shall be prescribed and established for the safe passage or storage of the waters. No changes shall be made to the prescribed grades and contours of the specified floodways, except by permit in accordance with section 112-106 of Chapter 112. No trees or shrubbery should be planted in the drainage way that will obstruct the flow of stormwater. (e) Manholes. All sanitary sewer manholes constructed in a floodplain or in an area designed for the storage or passage of flood or stormwater, shall be provided with either a watertight manhole cover or be constructed with a rim elevation of a minimum one foot above the high water elevation of the base flood, whichever is applicable to the specific area. The engineer of record shall identify which sanitary sewer manholes within the project limits are subject to this requirement, and coordinate with city water and light regarding the appropriate remedy. (f) Floor elevations. (1) Any proposed lot or lots located in a local or FEMA special flood hazard area (SFHA) shall be identified as such on the record plat along with the effective base flood elevation (BFE). (2) The designed lowest floor of any structure to be located in a local or FEMA designated SFHA shall be established by a professional engineer registered in the state, using good engineering practice. (3) An elevation certificate (FEMA Form 086-0-33) shall be used to certify the elevation of any structure to be constructed in local or FEMA designated SFHA. Certificates may be prepared and sealed by either a professional engineer or a land surveyor provided that person is registered in the state. An elevation certificate must be prepared, submitted, and approved at the following times during the construction of any structure in a local or FEMA designated SFHA: a. Construction drawings: Before a building permit is issued for the anticipated construction activity; b. Building under construction: Before the framing of any building wall system. Not required, but is recommended that this certification be performed before any slab on grade or elevated slab is poured; and c. Finished construction: Prior to issuance of certificate of occupancy and only after all construction has been completed.

(Ord. No. 08:099, § 2(4.2), 12-18-2008; Ord. No. 09:008, 2-17-2009; Ord. No. 10:048, § 2, 6-15-2010; Ord. No. 14:059, § 1, 10-21-2014; Ord. No. 16:059, § 1, 10-4-2016; Ord. No. 21:037, § 2, 9-21-2021)

Ask a question about Jonesboro law

Corpus searches the Jonesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.