For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 35-191 — Additional pretreatment measures

The Little Rock City Code, Revised 1988 (Supp. No. 83: codified through Ordinance No. 22,703, enacted December 16, 2025) · Little Rock City Code § 35-191

Corpus is an independent public-information project, not the official City of Little Rock website. Stable reference: corpuslaw.us/code/6f627d86-7808-414c-8419-247b28bccd6e

Sec. 35-191. - Additional pretreatment measures.

A. If any waters or wastes which are discharged or which are to be discharged into the public sewers contain or possess any of the characteristics enumerated in sections 35-175(A) and (B), 35-178, and/or 35-389 and in the judgment of the CEO, may have a deleterious effect upon the sewage works, processes, equipment, sludges, or receiving waters, or which otherwise creates a hazard to life or constitutes a public nuisance, the CEO may (a) reject the wastes, (b) require pretreatment to an acceptable condition for discharge to the public sewer, and/or (c) require control over the quantities and rate of discharge. If the CEO requires the pretreatment or equalization of waste flows, the design and installation of the plants and equipment shall be subject to the review and approval of the CEO and subject to all applicable codes, ordinances, and laws. Where pretreatment or flow equalization facilities are provided for any waters or wastes, they shall be continuously maintained in satisfactory and effective operation by the owner or occupant at his own expense. B. Whenever deemed necessary, the CEO may require users to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage waste streams from industrial waste streams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this article. C. The CEO may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow-control facility to ensure equalization of flow. A wastewater discharge permit may be issued solely for flow equalization. D. Grease, oil, and sand interceptors shall be provided when, in the opinion of the CEO, they are necessary for the proper handling of wastewater containing excessive amounts of grease and oil, any flammable wastes, or sand; except that such interceptors shall not be required for residential users. All interception units shall be of type and capacity approved by the CEO and shall be so located to be easily accessible for cleaning and inspection. Such interceptors shall be inspected, cleaned, and repaired regularly, as needed, by the user at their expense. Storage, handling, transportation, and disposal of all wastes generated from such interceptors shall be performed in accordance with all applicable federal, state, and local regulations that pertain to that type and/or class of waste. E. Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter. F. When required by the CEO, the owner of any property serviced by a building sewer carrying industrial waste shall provide a secure sample point or sampling/inspection manhole which is constructed in accordance with the latest revision of the Little Rock Wastewater Specification Requirements for Sanitary Sewers. The secure sample point or sampling/inspection manhole shall be safely located and accessible to duly authorized employees and/or representatives of LRW at all times. When deemed necessary by the CEO, the secure sample point or sampling/inspection manhole shall be provided with meters or other appurtenances to facilitate the monitoring of the wastewater. The cost of the installation and maintenance of a secure sample point or sampling/inspection manhole shall be borne by the owner. Any construction and/or alteration of a secure sample point or sampling/inspection manhole shall be approved by the CEO before any construction has begun. Any secure sample point or sampling/inspection manhole located in a parking lot or other area where any vehicles may reasonably be expected to be parked must be protected by a permanent barrier, railing, or other means if it is determined necessary by the CEO to ensure continued and uninterrupted access to the secure sample point or sampling/inspection manhole by LRW personnel. G. Whenever deemed necessary, the CEO may require the pretreatment system operator(s) to be licensed in accordance with State of Arkansas Regulation Number 3, including all amendments thereto, for the operation of industrial wastewater treatment systems.

(Ord. No. 19,895, § 3.2, 12-21-07)

Ask a question about Little Rock law

Corpus searches the Little Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.